Dimplex Cavendish [7/16] Effect
![Dimplex Cavendish [7/16] Effect](/views2/1329430/page7/bg7.png)
Installation Instructions
Before installing this appliance, we recommend that;
1. You have your chimney cleaned by a competent
chimney sweep.
2. You block o the chimney ue.
This procedure is important for the ecient operation
of the heating unit and will also reduce heat loss up the
chimney.
Installation.
Ensure that all packing items are removed (read any
warning labels carefully).
Retain all packing for possible future use, in the event
of moving or returning the appliance to your supplier.
To install the appliance;
1. Remove the replace grate, ashpan etc.
2. The ashbed grate should be stored away for possible
future use.
3. Clean the hearth of any ash residue or dust etc.
At the rear of the appliance, two adjustable supports are
provided for levelling, where the base of the replace
opening is raised above the level of the hearth.
You are now ready to install the electric re into your
replace.
Make sure the unit is switched OFF.
Hold the re by the sides of surround and gently
manoeuvre into position. Plug the re into a 13amp/240
volt outlet. Ensure that the supply cable exits at the front
of the re, at the right or left hand corner to suit your
supply socket location and is not trapped under the re
such that it might cause it to be damaged.
Before using the manual controls rstly ll the water
tank (See ‘Maintenance’, ‘Filling the water tank’).
Manual Controls.
The Opti-myst Manual controls are located beneath the
hinged canopy cover. Raise the canopy cover to access the
controls. (See Fig.2 for Manual Control lay out)
Switch ‘A’:- Controls the electricity supply to the heater.
Note: This switch must be in the ‘ON’ ( I ) position for the
heater to operate with or without heat.
Switch ‘B’:- Controls the function of the re.
Press once to turn on ame eect. This will be
indicated by one beep.
Although the main lights operate immediately it will
take a further 30 seconds before the ame eect
starts.
Press again to give ame eect and half heat.
This will be indicated by two beeps.
Press again to give ame eect and full heat.
This will be indicated by three beeps.
Press again to return to ame eect only.
This will be indicated by one beep.
Press to put re in to standby mode.
This will be indicated by one beep.
Control Knob ‘C’:- Controls the intensity of the ame
eect.
Turning the control knob Clockwise increases
the ame eect, turning the control knob Anti
Clockwise will decrease the ame eect.
Control Knob ‘D’:- Controls the Electronic Thermostat
setting.
Turning the control knob Clockwise will decrease
the temperature setting, turning the control knob
Anti Clockwise will increase the temperature setting.
LED ‘E’:- When this is illuminated it indicates that the water
tank is empty. You will hear two beeps.
When the water is empty the main lamps go out. See
instructions under ‘Maintenance’, ‘Filling the water tank’.
When this procedure is complete, the main lamps will
illuminate but it will take 30 seconds before the ames
return.
Electronic Thermostat
The thermostat controls the heat output according to the
room temperature. This ensures that the heater will not
produce heat unnecessarily when the room is warm.
To set the temperature you require, turn the thermostat
control knob ‘D’ (See Fig.2) Anti-Clockwise until the
desired temperature is reached. Alternatively to heat
a cold room quickly, turn the thermostat control knob
‘D’ (See g.2) up fully. When the room has reached the
desired temperature, turn the thermostat control knob
‘D’ (See Fig.2) clockwise until the desired heat setting is
achieved.
The heater will now automatically operate at this
temperature.
Remote Control Operation
On the control panel, Switch A (see Fig.2) must be in the
‘ON’ ( I ) position in order for the remote control to oper-
ate. There are 3 buttons on the remote control. (See Fig.7)
To operate correctly the remote must be pointed towards
the front fuel eect.
The remote control functions are as follows:
Press once to turn on Flame eect only.
This will be indicated by one beep.
Press once to turn on Half heat and Flame
eect.
This will be indicated by two beeps.
Press again to turn on Full heat and Flame
eect.
This will be indicated by three beeps.
Standby
This will be indicated by one beep.
Содержание
- Cavendish csh20 chesford csd20 1
- Fig fig 2
- Dimplexopti mystinsetfires 6
- Important safety advice when using electrical appliances basic precautions should always be followed to reduce the risk of fire electrical shock and injury to persons including the following if the appliance is damaged check with the supplier before installation and operation do not use outdoors do not use in the immediate surroundings of a bath shower or swimming pool do not locate the heater immediately below a fixed socket outlet or connection box this appliance is not intended for use by children or other persons without assistance or supervision if their physical sensory or mental capabilities prevent them from using it safely children should be supervised to ensure that they do not play with the appliance do not use this heater in series with a thermal control a program controller a timer or any other device that switches on the heat automatically since a fire risk exists when the heater is accidentally covered or displaced ensure that furniture curtains or other combustible mate 6
- Model cavendishcsh20 brassinset chesfordcsd20 titaniuminset 6
- The heater carries the warning symbol indicating that it must not be covered 6
- Effect 7
- Turningthecontrolknobclockwiseincreases theflameeffect turningthecontrolknobanti 7
- Givetheflamegeneratorsometimetoreactto changesyoumaymakeontheflamecontrolknob 8
- Checktheplugisconnectedtowall socketcorrectly switch a fig isinthe on i posi tion pressswitch b fig untilyoucanhear onebeeponly forflameeffect 10
- Followinstructionsunder mainte nance fillingthewatertank 10
- Symptom cause corrective action 10
- Troubleshooting 10
- Встраиваемыекаминыdimplexopti myst 11
- Модель cavendishcsh20 вставкалатунь chesfordcsd20 вставкатитан 11
- Вращениерегуляторапочасовойстрелке увеличиваетинтенсивностьэффектапламени вращениерегуляторапротив 12
- Пламени 12
- Генераторупламенитребуетсянекотороевремя дляреакциинаизменения выполненныеручкой регулировкипламени 13
- Признак причина способ устранения 15
- Устранениенеисправностей 15
Похожие устройства
- Dimplex Cassette 400 NH Инструкция по эксплуатации
- Smeg UW60132D Инструкция по эксплуатации
- Smeg UW6070D Инструкция по эксплуатации
- Dimplex Cassette 600 NH Инструкция по эксплуатации
- Dimplex Danville Black FB2 Инструкция по эксплуатации
- Expo PM-VAR20 цвета RAL20 Инструкция по эксплуатации
- Expo PM-VAR20 цвета RAL20 Каталог модульных систем Expo
- Expo PC-VAR20 цвета RAL20 Инструкция по эксплуатации
- Expo PC-VAR20 цвета RAL20 Каталог модульных систем Expo
- Expo PM-VAR22 цвета RAL20 Инструкция по эксплуатации
- Expo PM-VAR22 цвета RAL20 Каталог модульных систем Expo
- Expo PM-VAR21 цвета RAL20 Инструкция по эксплуатации
- Expo PM-VAR21 цвета RAL20 Каталог модульных систем Expo
- Dimplex Cassette L Инструкция по эксплуатации
- Dimplex Engine (56-400) Инструкция по эксплуатации
- Expo PC-VAR22 цвета RAL20 Инструкция по эксплуатации
- Expo PC-VAR22 цвета RAL20 Каталог модульных систем Expo
- Dimplex Juneau Инструкция по эксплуатации
- Dimplex Engine (56-600 LL) Инструкция по эксплуатации
- Dimplex Engine (56-600 BB) Инструкция по эксплуатации