GB
5.3. Functioning
Temperature Blast chilling
Select the blast chilling by pressing key: led
and will blink. The display shows the end
blast chilling temperature value.
By pressing the and keys the
temperature value (+3°C) can be changed.
Insert the core probe into the product.
Press key to start. Led and will be
permanently on.
The test for the proper insertion of the probe will
start.
If the test gives a positive result, the blast chilling
cycle starts, in case of negative result the
machine will run a timed blast chilling (see proper
chapter)
During blast chilling the display shows the
temperature detected by the core probe. By
pressing the key, temperature detected by
the chamber probe can be visualized.
If the product temperature reaches the
established value within the set blast chilling time,
the cycle is considered as completed and a
preserving cycle is automatically started and an
intermittent sound confirm the correct conclusion
of the cycle.
In case the product temperature does not reach
the on parameter r5 established value, the cycle
continues: the led will blink accompanied by
an intermittent sound. To stop the alarm press a
key.
As soon as product temperature is lower than the
established value the blast chilling cycle is
considered as completed and a preserving cycle
is automatically started.
During preservation the display shows the
temperature detected by the chamber probe; LED
is switched on.
Press to conclude the preservation cycle.
Hard Temperature Blast Chilling cycle
Select blast chilling by pressing key: LEDs
and will blink. To select the hard cycle
press : LED blinks.
The display show the end blast chilling
temperature. Using and key the end
blast chilling temperature (+C) can be changed.
Insert the core probe into the product. Start the
cycle by pressing the key. LED ,
and are permanently on.
The test for the proper insertion of the probe will
start.
If the test gives a positive result, the blast chilling
cycle starts, in case of negative result the
machine will run a timed blast chilling (see proper
chapter)
The working set point of the hard phase is
established on parameter r9. Once the
temperature detected by the core probe
corresponds to the value established on
parameter r13, the hard phase is considered as
completed.
During blast chilling the display shows the
temperature detected by the core probe. By
pressing the key, temperature detected by
the chamber probe can be visualized.
1
3
2
1
2