Mitsubishi Electric PCA-RP50KAQ / SUZ-KA50VA [3/32] Fig 2 1

Mitsubishi Electric PCA-RP71KAQ / PU-P71VHAR [3/32] Fig 2 1
3
3. Installing the indoor unit
2. Installation location
(mm)
236Min.500
680
Max.250
W
Min.270
Min.300
123
456
78
A

236
B
2
75
80320
680
2
19046
6
233
246
C
D
233
246
86 285
138
126
19046
3.1. Check the indoor unit accessories (Fig. 3-1)
The indoor unit should be supplied with the following accessories
(contained in the inside of the intake grille).
Accessory name Q’ty
1
Washer 4 pcs
2
Pipe cover 1 pc Large size (For gas tubing)
3
Pipe cover 1 pc Small size (For liquid tubing)
4
Band 4 pcs
5
Joint socket 1 pc Marked with “UNIT”
6
Socket cover 1 pc
7
Drain tubing cover 1 pc
8
Flare nut 1 pc ø6.35 (RP60 only)
3.2. Preparation for installation (Fig. 3-2)
3.2.1. Suspension bolt installing spacing
(mm)
Models A B
RP35, 50 917 960
RP60, 71 1237 1280
RP100, 125, 140 1557 1600
3.2.2. Refrigerant and drain tubing location
(mm)
Models C D
RP35, 50 184 203
RP60 179 203
RP71-140 180 200
A
Front side outlet
F
Left drain tubing
B
Left side outlet
G
Gas tubing
C
Right side outlet
H
Liquid tubing
D
Independent piece (Removable)
I
Rubber plug
E
Right drain tubing
J
with Joint socket
5
In case of the rear pipe arrangement, make sure to remove the shaded portions
from the
D
independent piece. Then put the
D
independent piece back in initial
position.
(The heat exchanger might be clogged because of dust)
Fig. 2-1
2.1. Outline dimensions (Indoor unit) (Fig. 2-1)
Select a proper position allowing the following clearances for installation and main-
tenance.
Models W
RP35, 50 960
RP60, 71 1280
RP100, 125, 140 1600
Warning:
Mount the indoor unit on a ceiling strong enough to withstand the weight of
the unit.
2.2. Outline dimensions (Outdoor unit)
Refer to the outdoor unit installation manual.
Fig. 3-1
70+6
Fig. 3-2
(mm)