Mitsubishi Electric PSA-RP125KA / PUHZ-P125VHA [14/36] Function selection
![Mitsubishi Electric PSA-RP125KA / PUHZ-ZRP125VKA [14/36] Function selection](/views2/1331321/page14/bge.png)
14
[Detailed setting]
[4]-1 CHANGE LANGUAGE setting
The language that appears on the dot display can be selected.
• Press the [
MENU] button to change the language.
English (GB), German (D), Spanish (E), Russian (RU),
Italian (I), Chinese (CH), French (F), Japanese (JP)
Refer to the dot display table.
[4]-2 Function limit
(1) Operation function limit setting (operation lock)
• To switch the setting, press the [
ON/OFF] button .
no1: Operation lock setting is made on all buttons other than
the [
ON/OFF] button .
no2: Operation lock setting is made on all buttons.
OFF (Initial setting value): Operation lock setting is not made.
* To make the operation lock setting valid on the normal screen, it
is necessary to press buttons (Press and hold down the [FILTER]
and [
ON/OFF] buttons at the same time for 2 seconds.)
on the normal screen after the above setting is made.
(2) Use of automatic mode setting
When the remote controller is connected to the unit that has auto-
matic operation mode, the following settings can be made.
• To switch the setting, press the [
ON/OFF] button .
ON (Initial setting value):
The automatic mode is displayed when the operation mode is
selected.
OFF:
The automatic mode is not displayed when the operation mode
is selected
.
(3) Temperature range limit setting
After this setting is made, the temperature can be changed within
the set range.
• To switch the setting, press the [
ON/OFF] button .
LIMIT TEMP COOL MODE:
The temperature range can be changed on cooling/dry mode.
LIMIT TEMP HEAT MODE:
The temperature range can be changed on heating mode.
LIMIT TEMP AUTO MODE:
The temperature range can be changed on automatic mode.
OFF (initial setting): The temperature range limit is not active.
* When the setting other than OFF is made, the temperature
range limit setting on cooling, heating and automatic mode is
made at the same time. However, the range cannot be limited
when the set temperature range has not changed.
• To increase or decrease the temperature, press the [
TEMP.
() or ( )] button .
• To switch the upper limit setting and the lower limit setting, press
the [ ] button . The selected setting will blink and the tem-
perature can be set.
• Settable range
Cooling/Dry mode:
Lower limit:19°C - 30°C Upper limit:30°C - 19°C
Heating mode:
Lower limit:17°C - 28°C Upper limit:28°C - 17°C
Automatic mode:
Lower limit:19°C - 28°C Upper limit:28°C - 19°C
8. Function Selection
[4]-3 Mode selection setting
(1) Remote controller main/sub setting
• To switch the setting, press the [
ON/OFF] button .
Main: The controller will be the main controller.
Sub: The controller will be the sub controller.
(2) Use of clock setting
• To switch the setting, press the [
ON/OFF] button .
ON: The clock function can be used.
OFF: The clock function cannot be used.
(3) Timer function setting
• To switch the setting, press the [
ON/OFF] button (Choose
one of the followings.).
WEEKLY TIMER (initial setting value):
The weekly timer can be used.
AUTO OFF TIMER:
The auto off timer can be used.
SIMPLE TIMER:
The simple timer can be used.
TIMER MODE OFF:
The timer mode cannot be used.
* When the use of clock setting is OFF, the “WEEKLY TIMER” can-
not be used.
(4) Contact number setting for error situation
• To switch the setting, press the [
ON/OFF] button .
CALL OFF:
The set contact numbers are not displayed in case of error.
CALL **** *** ****:
The set contact numbers are displayed in case of error.
CALL_:
The contact number can be set when the display is as shown
above.
• Setting the contact numbers
To set the contact numbers, follow the following procedures.
Move the blinking cursor to set numbers. Press the [
TEMP.
(
) and ( )] button to move the cursor to the right (left).
Press the [ CLOCK ( ) and ( )] button to set the num-
bers.
[4]-4 Display change setting
(1) Temperature display °C/°F setting
• To switch the setting, press the [
ON/OFF] button .
°C: The temperature unit °C is used.
°F: The temperature unit °F is used.
(2) Room air temperature display setting
• To switch the setting, press the [
ON/OFF] button .
ON: The room air temperature is displayed.
OFF: The room air temperature is not displayed.
(3) Automatic cooling/heating display setting
• To switch the setting, press the [
ON/OFF] button .
ON:
One of “Automatic cooling” or “Automatic heating” is displayed
under the automatic mode is running.
OFF:
Only “Automatic” is displayed under the automatic mode.
Содержание
- Air conditioners 1
- Bedieningshandleiding 1
- Bedienungshandbuch 1
- Driftsmanual 1
- Indoor unit 1
- Istruzioni di funzionamento 1
- Işletme elkitabı 1
- Manual de instrucciones 1
- Manual de operação 1
- Manuel d utilisation 1
- Operation manual 1
- Psa rp ka 1
- Εγχειριδιο οδηγιων χρησεωσ 1
- Руководство по эксплуатации 1
- Contents 2
- Disposing of the unit 2
- Safety precautions 2
- Symbols used in the illustrations 2
- Symbols used in the text 2
- Display section 3
- Operation section 3
- Parts names 3
- Floor standing 4
- Parts names 4
- Operation 5
- Screen configuration 5
- Setting the day of the week and time 5
- Turning on off 5
- Fan speed setting 6
- Information for multi system air conditioner outdoor unit mxz series 6
- Mode select 6
- Operation 6
- Temperature setting 6
- Airflow direction setting 7
- For wired remote controller 7
- Operation 7
- Ventilation 7
- Weekly timer 7
- Simple timer 8
- Auto off timer 10
- Error codes indication 11
- Locking the remote controller buttons opera tion function limit controller 11
- Other functions 11
- Function selection 12
- Function selection of remote controller 12
- The setting of the following remote controller functions can be changed using the remote controller function selection mode change the setting when needed 12
- Function selection 13
- Function selection 14
- Dot display table 15
- English german spanish russian italian chinese french japanese 15
- Function selection 15
- Selecting language 15
- Care and cleaning 16
- Indicates that the filter needs cleaning ask authorized people to clean the filter 16
- When resetting filter display when the filter button is pressed 2 times successively after cleaning the filter the display goes off and is reset 16
- Trouble shooting 17
- Specifications 18
- Trouble shooting 18
- Меры предосторожности 19
- Символика используемая в тексте 19
- Символы указанные на иллюстрациях 19
- Содержание 19
- Указывает что эта часть должна быть заземлена 19
- Утилизация прибора 19
- Вверх 20
- Вниз 20
- Вперед 20
- Встроенный датчик температуры 20
- Дисплей 20
- Загорается когда необходимо очистить фильтр 20
- Идентификация текущего 20
- Индикатор блокировки locked 20
- Индикатор выключения таймера timer is off 20
- Индикатор окружающей температуры 20
- Индикатор очистки воздушного фильтра clean the filter 20
- Индикатор скорости вентилятора 20
- Кнопка 20
- Кнопка вентиляции 20
- Кнопка включения 20
- Кнопка жалюзи 20
- Кнопка направления 20
- Кнопка проверки 20
- Кнопка режима кнопка возврата back 20
- Назад 20
- Наименование деталей 20
- Открытие дверцы 20
- Отображается в случае работы устройства в режиме вентиляции 20
- Отображаются после установки соответствующих таймеров 20
- П о к а з ы в а е т у с т а н о в л е н н у ю скорость вентилятора 20
- Показывает режим работы и т д поддержка отображения на других языках 20
- Показывает текущее время пока не будет установлен обычный таймер и таймер отключения 20
- Показывает текущий день недели 20
- Показывает целевую температуру 20
- Показывает что кнопки пульта дистанционного управления были блокированы 20
- Показывает что питание включено 20
- Показывает что таймер отключен 20
- Примечание 20
- Управление 20
- Наименование деталей 21
- Включение выключение 22
- Конфигурация дисплея 22
- Установка дня недели и времени 22
- Эксплуатация 22
- Выбор режима 23
- Информация для мультисистемного кондиционера наружный прибор серия mxz 23
- Настройка скорости вентилятора 23
- Настройка температуры 23
- Эксплуатация 23
- Вентиляция 24
- Для проводные пульты дистанционного управления 24
- Настройка направления воздушного потока 24
- Таймер 24
- Эксплуатация 24
- Простой таймер 25
- Таймер 25
- Таймер 26
- Таймер 27
- Таймер автоотключения 27
- Блокировка кнопок пульта дистанционного управления ограничение функциональности 28
- Индикация кодов ошибок 28
- Прочие функции 28
- В режиме выбора функции с помощью пульта дистанционного управления можно настраивать нижеприведенные функции при необходимости измените настройку 29
- Выбор функции 29
- Выбор функции с помощью пульта дистанционного управления 29
- Выбор функции 30
- Настройка языка английский 30
- Схема выбора функции 30
- Выбор функции 31
- Dot display table 32
- English german spanish russian italian chinese french japanese 32
- Selecting language 32
- Выбор функции 32
- Настройка языка 32
- Таблица точечного дисплея 32
- Данная индикация недоступна для пульта дистанционного управления 33
- Для сброса индикации filter фильтр если кнопку filter фильтр нажать быстро дважды после чистки фильтра данная индикация погаснет и функция вернется в исходное состояние 33
- Если с пульта дистанционного управления осуществляется управление двумя или более внутренними блоками срок действия фильтра определяется его типом индикация filter фильтр появляется на дисплее в случае необходимости очистки фильтра на главном внутреннем блоке когда индикация фильтра гаснет на дисплее функция восстанавливает кумулятивное время замены фильтра 33
- Индикация filter фильтр указывает на необходимость очистки фильтра после истечения определенного заданного срока его использования в нормальных условиях эксплуатации внутри помещения однако ввиду того что степень загрязненности фильтра определяется конкретными условиями эксплуатации необходимо производить очистку фильтра с учетом данного фактора 33
- Кумулятивный срок действия фильтра зависит от модели кондиционера 33
- Указывает на необходимость очистки фильтра обратитесь к специалистам для очистки фильтра 33
- Уход и чистка 33
- Исправление неполадок 34
- Исправление неполадок 35
- Примеры 35
- Технические характеристики 35
- Уровни шума 35
- Please be sure to put the contact address telephone number on this manual before handing it to the customer 36
Похожие устройства
- Mitsubishi Electric PSA-RP125KA / PUHZ-P125VHA Инструкция по установке
- Mitsubishi Electric PSA-RP100KA / PUHZ-P100VHA Инструкция по эксплуатации
- Mitsubishi Electric PSA-RP100KA / PUHZ-P100VHA Инструкция по установке
- Mitsubishi Electric PSA-RP125KA / PUHZ-ZRP125VKA Инструкция по эксплуатации
- Mitsubishi Electric PSA-RP125KA / PUHZ-ZRP125VKA Инструкция по установке
- Mitsubishi Electric PLA-RP140BA / PUHZ-ZRP140VKA Инструкция по эксплуатации
- Mitsubishi Electric PLA-RP140BA / PUHZ-ZRP140VKA Руководство по установке
- Mitsubishi Electric PLA-RP140BA / PUHZ-ZRP140VKA Сертификат
- Mitsubishi Electric PSA-RP71KA / PUHZ-ZRP71VHA Инструкция по эксплуатации
- Mitsubishi Electric PSA-RP71KA / PUHZ-ZRP71VHA Инструкция по установке
- EQTA BC03 Инструкция по эксплуатации
- Mitsubishi Electric PSA-RP140KA / PUHZ-P140YHA Инструкция по эксплуатации
- Mitsubishi Electric PSA-RP140KA / PUHZ-P140YHA Инструкция по установке
- Mitsubishi Electric PLA-RP71BA / PUHZ-SHW80VHA Инструкция по эксплуатации
- Mitsubishi Electric PLA-RP71BA / PUHZ-SHW80VHA Руководство по установке
- Mitsubishi Electric PLA-RP71BA / PUHZ-SHW80VHA Сертификат
- Mitsubishi Electric PSA-RP125KA / PUHZ-ZRP125YKA Инструкция по эксплуатации
- Mitsubishi Electric PSA-RP125KA / PUHZ-ZRP125YKA Инструкция по установке
- Mitsubishi Electric PLA-RP140BA / PUHZ-ZRP140YKA Инструкция по эксплуатации
- Mitsubishi Electric PLA-RP140BA / PUHZ-ZRP140YKA Руководство по установке