Mitsubishi Electric PSA-RP100KA / PUHZ-P100VHA [8/36] Simple timer
![Mitsubishi Electric PSA-RP140KA / PUHZ-P140YHA [8/36] Simple timer](/views2/1331321/page8/bg8.png)
8
C
C
TIME SUN
WEEKLY
10
C
TIMER
SUN
ON
OFF
WEEKLY
8
9
1
Timer Settings
1. Be sure that the weekly timer indicator is visible on the screen (at ).
2. Press the Timer Menu button
so that “Monitor” is indicated on the
screen (at ).
3. Press the Timer On/Off (Set Day) button
as necessary to select the
day you wish to view.
4. Press the
or Operation button (
or
) as necessary to change
the timer operation shown on the display (at ).
* Each press will advance to the next timer operation, in order of time
setting.
5. To close the monitor and return to the standard control screen, press
the Mode (Return) button .
<To Turn Off the Weekly Timer>
Press the Timer On/Off button
so that “Timer Off” appears at
10
.
Note:
By setting the day to “Sun Mon Tues Wed Thurs Fri Sat”, you can set the
same operation to be carried out at the same time every day.
(Example: Operation 2 above, which is the same for all days of the week.)
Setup Matrix
Op No. Sunday Monday ... Saturday
No. 1
• 8:30
• ON
• 23 °C
No. 2
• 10:00
• OFF
• 10:00
• OFF
• 10:00
• OFF
• 10:00
• OFF
...
No. 8
<Operation 1 settings for Sunday>
Start the air conditioner at 8:30, with
the temperature set to 23 °C.
<Operation 2 settings for every day>
Turn off the air conditioner at 10:00.
5. Press the appropriate Set Time button as necessary to set the de-
sired time (at ).
* As you hold the button down, the time first increments in minute in-
tervals, then in 10-minute intervals, and then in 1-hour intervals.
6. Press the ON/OFF button
to select the desired operation (ON or
OFF), at .
* Each press changes the next setting, in the following sequence: No
display (no setting) → “ON” → “OFF”
7. Press the appropriate Set Temperature button to set the desired
temperature (at ).
* Each press changes the setting, in the following sequence: No dis-
play (no setting)
24 25 ... 29 30 12 ... 23
No display.
(Available range: The range for the setting is 12 °C to 30 °C. The
actual range over which the temperature can be controlled, how-
ever, will vary according to the type of the connected unit.)
8. After making the appropriate settings at Steps 5, 6 and 7, press the
Filter
button to lock in the values.
To clear the currently set values for the selected operation, press and
quickly release the Check (Clear) button once.
* The displayed time setting will change to “—:—”, and the On/Off
and temperature settings will all disappear.
(To clear all weekly timer settings at once, hold down the Check
(Clear) button
for 2 seconds or more. The display will begin blink-
ing, indicating that all settings have been cleared.)
Note:
Your new entries will be cancelled if you press the Mode (Return) button
before pressing the Filter
button .
If you have set 2 or more different operations for exactly the same time,
only the operation with the highest Operation No. will be carried out.
9. Repeat Steps 3 to 8 as necessary to fill as many of the available cells
as you wish.
10. Press the mode (Return) button to return to the standard control
screen and complete the setting procedure.
11. To activate the timer, press the Timer On/Off button , so that the
“Timer Off” indication disappears from the screen. Be sure that the
“Timer Off” indication is no longer displayed.
* If there are no timer settings, the “Timer Off” indication will blink on
the screen.
<Setting the Weekly Timer>
C
SUN
ON
WEEKLY
Shows the selected operation (ON or OFF)
* Does not appear if operation is not set.
Shows the temperature setting
* Does not appear if temperature
is not set.
Shows the time
setting
<How to View the Weekly Timer Settings>
C
C
TIME SUN
WEEKLY
10
6.1.2. Simple Timer
■
You can set the simple timer in any of 3 ways.
• Start time only:
The air conditioner starts when the set time has elapsed.
• Stop time only:
The air conditioner stops when the set time has elapsed.
• Start & stop times:
The air conditioner starts and stops at the respective elapsed times.
■
The simple timer (start and stop) can be set only once within a 72-hour
period.
The time setting is made in hour increments.
Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same
time.
*2. The simple timer will not operate when any of the following conditions
is in effect.
The timer is off; the system is in malfunction state; a test run is in prog-
ress; the remote controller is undergoing self-check or remote control-
ler check; the user is in the process of selecting a function; the user is
in the process of setting the timer; the system is under central control.
(Under these conditions, On/Off operation is prohibited.)
ONHr
AFTER
SIMPLE
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK DAY
MONITOR/SET
CLOCK
ON/OFF
<To Turn On the Weekly Timer>
Press the Timer On/Off button so that the “Timer Off” indication (at
10
)
goes dark.
6. Timer
3. Press the Timer On/Off (Set Day) button
to set the day. Each press
advances the display at to the next setting, in the following se-
quence: “Sun Mon Tues Wed Thurs Fri Sat” → “Sun” → ... → “Fri” →
“Sat” → “Sun Mon Tues Wed Thurs Fri Sat”...
4. Press the or Operation button ( or ) as necessary to select
the appropriate operation number (1 to 8) .
* Your inputs at Steps 3 and 4 will select one of the cells from the ma-
trix illustrated below.
(The remote-controller display at left shows how the display would
appear when setting Operation 1 for Sunday to the values indicated
below.)
2. Press the Timer Menu button , so that the “Set Up” appears on the
screen (at ). (Note that each press of the button toggles the display
between “Set Up” and “Monitor”.)
Содержание
- Air conditioners 1
- Bedieningshandleiding 1
- Bedienungshandbuch 1
- Driftsmanual 1
- Indoor unit 1
- Istruzioni di funzionamento 1
- Işletme elkitabı 1
- Manual de instrucciones 1
- Manual de operação 1
- Manuel d utilisation 1
- Operation manual 1
- Psa rp ka 1
- Εγχειριδιο οδηγιων χρησεωσ 1
- Руководство по эксплуатации 1
- Contents 2
- Disposing of the unit 2
- Safety precautions 2
- Symbols used in the illustrations 2
- Symbols used in the text 2
- Display section 3
- Operation section 3
- Parts names 3
- Floor standing 4
- Parts names 4
- Operation 5
- Screen configuration 5
- Setting the day of the week and time 5
- Turning on off 5
- Fan speed setting 6
- Information for multi system air conditioner outdoor unit mxz series 6
- Mode select 6
- Operation 6
- Temperature setting 6
- Airflow direction setting 7
- For wired remote controller 7
- Operation 7
- Ventilation 7
- Weekly timer 7
- Simple timer 8
- Auto off timer 10
- Error codes indication 11
- Locking the remote controller buttons opera tion function limit controller 11
- Other functions 11
- Function selection 12
- Function selection of remote controller 12
- The setting of the following remote controller functions can be changed using the remote controller function selection mode change the setting when needed 12
- Function selection 13
- Function selection 14
- Dot display table 15
- English german spanish russian italian chinese french japanese 15
- Function selection 15
- Selecting language 15
- Care and cleaning 16
- Indicates that the filter needs cleaning ask authorized people to clean the filter 16
- When resetting filter display when the filter button is pressed 2 times successively after cleaning the filter the display goes off and is reset 16
- Trouble shooting 17
- Specifications 18
- Trouble shooting 18
- Меры предосторожности 19
- Символика используемая в тексте 19
- Символы указанные на иллюстрациях 19
- Содержание 19
- Указывает что эта часть должна быть заземлена 19
- Утилизация прибора 19
- Вверх 20
- Вниз 20
- Вперед 20
- Встроенный датчик температуры 20
- Дисплей 20
- Загорается когда необходимо очистить фильтр 20
- Идентификация текущего 20
- Индикатор блокировки locked 20
- Индикатор выключения таймера timer is off 20
- Индикатор окружающей температуры 20
- Индикатор очистки воздушного фильтра clean the filter 20
- Индикатор скорости вентилятора 20
- Кнопка 20
- Кнопка вентиляции 20
- Кнопка включения 20
- Кнопка жалюзи 20
- Кнопка направления 20
- Кнопка проверки 20
- Кнопка режима кнопка возврата back 20
- Назад 20
- Наименование деталей 20
- Открытие дверцы 20
- Отображается в случае работы устройства в режиме вентиляции 20
- Отображаются после установки соответствующих таймеров 20
- П о к а з ы в а е т у с т а н о в л е н н у ю скорость вентилятора 20
- Показывает режим работы и т д поддержка отображения на других языках 20
- Показывает текущее время пока не будет установлен обычный таймер и таймер отключения 20
- Показывает текущий день недели 20
- Показывает целевую температуру 20
- Показывает что кнопки пульта дистанционного управления были блокированы 20
- Показывает что питание включено 20
- Показывает что таймер отключен 20
- Примечание 20
- Управление 20
- Наименование деталей 21
- Включение выключение 22
- Конфигурация дисплея 22
- Установка дня недели и времени 22
- Эксплуатация 22
- Выбор режима 23
- Информация для мультисистемного кондиционера наружный прибор серия mxz 23
- Настройка скорости вентилятора 23
- Настройка температуры 23
- Эксплуатация 23
- Вентиляция 24
- Для проводные пульты дистанционного управления 24
- Настройка направления воздушного потока 24
- Таймер 24
- Эксплуатация 24
- Простой таймер 25
- Таймер 25
- Таймер 26
- Таймер 27
- Таймер автоотключения 27
- Блокировка кнопок пульта дистанционного управления ограничение функциональности 28
- Индикация кодов ошибок 28
- Прочие функции 28
- В режиме выбора функции с помощью пульта дистанционного управления можно настраивать нижеприведенные функции при необходимости измените настройку 29
- Выбор функции 29
- Выбор функции с помощью пульта дистанционного управления 29
- Выбор функции 30
- Настройка языка английский 30
- Схема выбора функции 30
- Выбор функции 31
- Dot display table 32
- English german spanish russian italian chinese french japanese 32
- Selecting language 32
- Выбор функции 32
- Настройка языка 32
- Таблица точечного дисплея 32
- Данная индикация недоступна для пульта дистанционного управления 33
- Для сброса индикации filter фильтр если кнопку filter фильтр нажать быстро дважды после чистки фильтра данная индикация погаснет и функция вернется в исходное состояние 33
- Если с пульта дистанционного управления осуществляется управление двумя или более внутренними блоками срок действия фильтра определяется его типом индикация filter фильтр появляется на дисплее в случае необходимости очистки фильтра на главном внутреннем блоке когда индикация фильтра гаснет на дисплее функция восстанавливает кумулятивное время замены фильтра 33
- Индикация filter фильтр указывает на необходимость очистки фильтра после истечения определенного заданного срока его использования в нормальных условиях эксплуатации внутри помещения однако ввиду того что степень загрязненности фильтра определяется конкретными условиями эксплуатации необходимо производить очистку фильтра с учетом данного фактора 33
- Кумулятивный срок действия фильтра зависит от модели кондиционера 33
- Указывает на необходимость очистки фильтра обратитесь к специалистам для очистки фильтра 33
- Уход и чистка 33
- Исправление неполадок 34
- Исправление неполадок 35
- Примеры 35
- Технические характеристики 35
- Уровни шума 35
- Please be sure to put the contact address telephone number on this manual before handing it to the customer 36
Похожие устройства
- Mitsubishi Electric PSA-RP100KA / PUHZ-P100VHA Инструкция по установке
- Mitsubishi Electric PSA-RP125KA / PUHZ-ZRP125VKA Инструкция по эксплуатации
- Mitsubishi Electric PSA-RP125KA / PUHZ-ZRP125VKA Инструкция по установке
- Mitsubishi Electric PLA-RP140BA / PUHZ-ZRP140VKA Инструкция по эксплуатации
- Mitsubishi Electric PLA-RP140BA / PUHZ-ZRP140VKA Руководство по установке
- Mitsubishi Electric PLA-RP140BA / PUHZ-ZRP140VKA Сертификат
- Mitsubishi Electric PSA-RP71KA / PUHZ-ZRP71VHA Инструкция по эксплуатации
- Mitsubishi Electric PSA-RP71KA / PUHZ-ZRP71VHA Инструкция по установке
- EQTA BC03 Инструкция по эксплуатации
- Mitsubishi Electric PSA-RP140KA / PUHZ-P140YHA Инструкция по эксплуатации
- Mitsubishi Electric PSA-RP140KA / PUHZ-P140YHA Инструкция по установке
- Mitsubishi Electric PLA-RP71BA / PUHZ-SHW80VHA Инструкция по эксплуатации
- Mitsubishi Electric PLA-RP71BA / PUHZ-SHW80VHA Руководство по установке
- Mitsubishi Electric PLA-RP71BA / PUHZ-SHW80VHA Сертификат
- Mitsubishi Electric PSA-RP125KA / PUHZ-ZRP125YKA Инструкция по эксплуатации
- Mitsubishi Electric PSA-RP125KA / PUHZ-ZRP125YKA Инструкция по установке
- Mitsubishi Electric PLA-RP140BA / PUHZ-ZRP140YKA Инструкция по эксплуатации
- Mitsubishi Electric PLA-RP140BA / PUHZ-ZRP140YKA Руководство по установке
- Mitsubishi Electric PLA-RP140BA / PUHZ-ZRP140YKA Сертификат
- EQTA BC10P Инструкция по эксплуатации