Toshiba MMK-AP0243H [8/152] 1 indoor unit
![Toshiba MMK-AP0123H [8/152] 1 indoor unit](/views2/1332779/page8/bg8.png)
8
1. CONSTRUCTION VIEWS (EXTERNAL VIEWS)
1-1. Indoor Unit
Model:
MMK-AP0073H (IN), MMK-AP0093H (IN), MMK-AP0123H (IN),
MMK-AP0153H (IN), MMK-AP0183H (IN), MMK-AP0243H (IN)
Wireless remote controller
Remote controller holder
1050
50
56 24
82 26
132 568 200 150
72 78
228
320
204
163
132 786
235
47 215.5 262.5 262.5 153.5 109
235
215 215
85
23
132
320
40
40
50
73.5
7
50
73.5
7
Front panel
Air filter
Heat exchanger
Installation plate hanger
Installation plate hanger
Connecting pipe (0.39m)
(07, 09, 12 series; 9.5mm
15, 18 series; 12.7mm
24 series; 15.9mm)
Drain hose
(0.5mm)
Connecting pipe (0.44m)
(07, 09, 12 series; 6.4mm
15, 18 series; 6.4mm
24 series; 9.5mm)
Air inlet
Knock out system Knock out system
Hanger
Hanger
Center line Instrallation plate outline
Hanger
Содержание
- Contents 2
- Safety caution 3
- The important contents concerned to the safety are described on the product itself and on this service manual please read this service manual after understanding the described items thoroughly in the following contents and keep them 3
- Warning 3
- Caution 4
- Warning 4
- Cautions on installation service 5
- New refrigerant r410a 5
- Pipe materials 5
- Safety caution concerned to new refrigerant 5
- 1 required tools for r410a mixing of different types of oil may cause a trouble such as generation of sludge clogging of capillary etc accordingly the tools to be used are classified into the following three types 1 tools exclusive for r410a those which cannot be used for conventional refrigerant r22 2 tools exclusive for r410a but can be also used for conventional refrigerant r22 3 tools commonly used for r410a and for conventional refrigerant r22 the table below shows the tools exclusive for r410a and their interchangeability 6
- Also prepare the following equipments for other installation method and run check 1 clamp meter 2 thermometer 3 insulation resistance tester 4 electroscope 6
- General tools conventional tools can be used 6
- In addition to the above exclusive tools the following equipments which serve also for r22 are necessary as the general tools 6
- Note 1 when flaring is carried out for r410a using the conventional flare tools adjustment of projection margin is necessary for this adjustment a copper pipe gauge etc are necessary note 2 charging cylinder for r410a is being currently developed 6
- Spanner or monkey wrench 9 hole core drill 10 hexagon wrench opposite side 4mm 11 tape measure 12 metal saw 6
- Tools exclusive for r410a the following tools for r410a are required 6
- Tools whose specifications are changed for r410a and their interchangeability 6
- Vacuum pump use vacuum pump by attaching vacuum pump adapter 2 torque wrench 3 pipe cutter 4 reamer 5 pipe bender 6 level vial 7 screwdriver 6
- Do not discharge flon gas into the air to protect the earth environment 7
- Environment 7
- Mm hexagonal wrench is required 7
- Recharge of refrigerant 7
- Use vacuum pump method for an air purge discharge of air in the connecting pipe in installation time 7
- When recharge of the refrigerant is required charge the new refrigerant with the specified amount in the procedure as described below 7
- 1 indoor unit 8
- Construction views external views 8
- Louver motor 9
- Model mmk ap0073h in mmk ap0093h in mmk ap0123h in mmk ap0153h in mmk ap0183h in mmk ap0243h in 9
- Pulse motor valve 9
- Wiring diagram 9
- 1 parts rating 10
- 2 name of each part 10
- Air filter 10
- Air inlet grille 10
- Air outlet louver 10
- Earth screw 10
- Parts rating 10
- 3 parts name of remote controller 11
- 9 20 19 11
- Display section 11
- 9 20 19 12
- Air volume select display 12
- Central control display 12
- Louver lock display 4 way air discharge cassette type 2h series only 12
- Louver number display exapmle 01 02 03 04 12
- Mode select control display 12
- Operation ready display 12
- Unit number display 12
- Operation section 13
- Option 13
- Remote controller sensor 13
- 4 correct usage 14
- Preparation 14
- Requirement 14
- 5 adjustment of wind direction 15
- Automatic operation super heat recovery type only 15
- Caution 15
- For all models 15
- For under ceiling 1 way air discharge cassette high wall type 15
- In case of cooling 15
- In case of heating for heat pump model only 15
- In cooling operation 15
- In heating operation for heat pump model only 15
- Right left air direction adjustment 15
- When restarting the operation after stop 15
- 4 way air discharge cassette type 1h series compact 4 way type 16
- 4 way air discharge cassette type 2h series 16
- For cooling cool 16
- For heating heat 16
- In cooling operation 16
- In heating operation for heat pump model only 16
- How to set up the wind direction 17
- How to start swinging 17
- How to stop swinging 17
- In cool dry operation 17
- In fan operation 17
- In heat operation 17
- Unit select button 17
- 6 timer operation 18
- Timer operation 18
- 7 installation 19
- Be careful with noise or vibrations 19
- Caution 19
- Do not install the air conditioner in the following places 19
- Electrical wiring 19
- Installation place 19
- Make sure that a leakage breaker is connected 19
- Use a leakage breaker with an appropriate capacity 19
- Warning 19
- 8 maintenance 20
- Caution 20
- Checks before operation 20
- Cleaning of air filters 20
- If you do not plan to use the unit for more than 1 month 20
- Warning 20
- Ask the dealer or an installation professional to re install the air conditioner to a new place or move it to another place and to observe the following items if the air conditioner is inappropriately installed by yourself it may cause electric shock or fire 21
- Be sure to clean the heat exchanger with pressurized water if an commercially detergent strong alkaline or acid cleaning agent is used the surface treatment of the heat exchanger will be marred which may degrade the self cleaning performance for details contact the dealer 21
- Caution 21
- For environmental conservation it is strongly recommended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner when the air conditioner is operated for a long time periodic maintenance once a year is recommended furthermore regularly check the outdoor unit for rust and scratches and remove them or apply rustproof treatment if necessary as a general rule when an indoor unit is operated for 8 hours or more daily clean the indoor unit and outdoor unit at least once every 3 months ask a professional for this cleaning maintenance work such maintenance can extend the life of the product though it involves the owner s expense failure to clean the indoor and outdoor units regularly will result in poor performance freezing water leak age and even compressor failure 21
- Maintenance list 21
- Re installation 21
- Warning 21
- Cleaning of air filter 22
- Cleaning the air inlet grille 22
- High wall type 22
- Return the air filter 22
- 9 air conditioner operations and performance 23
- Air conditioner operating conditions 23
- Characteristics of heating operation for heat pump model only 23
- Check before operation 23
- Cooling heating operation of modular multi system air conditioner 23
- Defrost operation during heating operation for heat pump model only 23
- Fan rotation of stopped unit 23
- Heating capacity for heat pump model only 23
- Main power failure 23
- Minutes protection 23
- Protective device high pressure switch 23
- Warning 23
- 10 when the following symptoms are found 24
- Any other unusual conditions are observed 24
- Caution 24
- Check the points described below before asking repair servicing 24
- If any of the following conditions occur turn off the main power supply switch and immediately contact the dealer switch operation does not work properly the main power fuse often blows out or the circuit breaker is often activated a foreign matter or water fall inside the air conditioner when the air conditioner does not operate even after the cause of the protective device activation has been removed the operation lamp and on the remote controller are flashing 24
- Confirmation and check 25
- Confirmation of error history 25
- 11 installation manual 26
- Accessory parts 26
- Precautions for safety 26
- Selection of installation place 27
- Installation of indoor unit 28
- Cutting a hole and mounting installation plate 29
- How to remove the drain hose 29
- Piping and drain hose installation 29
- Bend the connection pipe within a radius of 30 mm 30
- Caution 30
- How to fix the drain hose 30
- How to fix the drains cap 30
- How to remove the drain hose 30
- How to remove the drains cap 30
- In case of bottom right or bottom left piping 30
- In case of right or left piping 30
- Left hand connection with piping 30
- Piping and drain hose installation 30
- Caution 31
- Drainage 31
- Indoor unit fixing 31
- Permissible piping length and height difference 31
- Pipe size 31
- Refrigerant piping 31
- Electric work 32
- Address setup 33
- Caution 33
- Control wiring between indoor and outdoor units 33
- Control wiring central controller wiring 33
- Electric work 33
- Indoor unit power supply 33
- Power supply wire and communication wires specifications 33
- Wired remote controller wiring 33
- Caution 34
- Electric work 34
- How to connect the power supply 34
- Requirement 34
- Wired remote controller wiring 34
- Wiring and control wiring 34
- Wiring connection 34
- Applicable controls 35
- Basic procedure for changing settings 35
- Caution 35
- Changing of settings of for ap plicable controls 35
- Electric work 35
- How to connect the wiring of flow selector unit 35
- Procedure 35
- Requirement 35
- Wiring connection for flow selector unit 35
- Adjustment of air direction 36
- Applicable controls 36
- Change of lighting time of filter sign 36
- Group control 36
- To secure better effect of heating 36
- Test run 37
- A wired remote controller is necessary for this function this function cannot be operate with a wireless remote controller 38
- After confirmation push 38
- Button because all the trouble 38
- Button to return to theusual display 38
- Buttons at the same time for 4 seconds or more the following display ap pears if service check is displayed the mode enters in the trouble history mode 01 order of trouble history is displayed in code no window check code is displayed in check window indoor unit address in which an error occurred is displayed in unit no 38
- Check code indoor unit no in which an error occurred 38
- Do not push 38
- Every pushing of temp button used to set temperature the trouble history stored in memory is displayed in order the numbers in code no indicate code no 01 latest 04 oldest 38
- Flashing 38
- Goes off alt flashing is alternately when there are two flashing led sim simultaneous flashing when there are two flashing led 38
- History of the indoor unit will be deleted 38
- Lighting 38
- On the remote controller wired remote controller central control remote controller and the interface p c board of the outdoor unit i f a check display lcd remote controller or 7 segment display on the outdoor interface p c board to display the operation is provided therefore the operation status can be known using this selfdiagnosis function a trouble or position with error of the air conditioner can be found as shown in the table below 38
- The following list shows each check code find the check contents from the list according to part to be checked in case of check from indoor remote controller see wired remote controller display in the list in case of check from outdoor unit see outdoor 7 segment display in the list in case of check from indoor unit with wireless remote controller see sensor block display of receiving unit in the list ai net artificial intelligence ipdu intelligent power drive unit 38
- Troubleshooting 38
- When a trouble occurred in the air conditioner the check code and the indoor unit no appear on the display part of the remote controller the check code is only displayed during the operation if the display disappears operate the air conditioner according to the following confirmation of error history for confirmation 38
- When a trouble occurred on the air conditioner the trouble history can be confirmed with the following procedure the trouble history is stored in memory up to 4 troubles the history can be confirmed from both operat ing status and stop status 38
- When pushing 38
- Error detected by tcc link central control device 39
- Tcc link toshiba carriea cominication link 39
- Refrigerating cycle diagram 40
- 1 control specifications 41
- Adjustment range remote controller setup temperature c 41
- Automatic capacity control 41
- Based on the difference between ta and ts the operation capacity is determined by the outdoor unit 41
- Based on the operation mode selecting command from the remote controller the operation mode is selected 41
- Control outline 41
- Distinction of outdoor unit when the power supply is reset the outdoors are distinguished and the control is selected according to the distinguished result 2 if resetting the power supply during occurrence of a trouble the check code is once cleared after on off button of the remote controller was pushed and the operation was resumed if the abnormal status continues the check code is again displayed on the remote controller 41
- Except while sensor of the remote controller is controlled code no 32 0001 41
- Operation mode selection 41
- Outline of specifications 41
- Remarks 41
- Room temp control 41
- Setting at shipment 41
- Shift of suction tem perature in heating operation 41
- Ts setup temp ta room temp 41
- Using the item code 06 the setup temperature in heating operation can be corrected 41
- When power supply is reset 41
- 1 indoor unit 48
- Applied control 48
- Table function selecting item numbers dn items necessary to perform the applied control at the local site are described 49
- 1 2 applied control in indoor unit 50
- 1 control items 50
- 2 wiring diagram using remote control interface tcb ifcb 4e2 50
- Indoor unit capacity 50
- Item code 10 50
- Item code 11 50
- Remote location on off control box tcb ifcb 4e2 50
- Wiring and setup 50
- Function 51
- Operation 51
- Ventilating fan control from remote controller 51
- Wiring 51
- Control items 52
- Function 52
- Leaving on prevention control 52
- Operation 52
- Power peak cut from indoor unit 52
- Wiring 52
- Indoor p c board 53
- Mcc 1510 53
- Wall type p c board optional switch connector specifications 54
- 1 troubleshooting summary 55
- Before troubleshooting 55
- Troubleshooting 55
- Troubleshooting procedure 55
- 2 1 check code list 56
- 2 check method 56
- Flashing goes off alt flashing is alternately when there are two flashing led sim simultaneous flashing when there are two flashing led 56
- Ipdu intelligent power drive unit 56
- Lighting 56
- On the remote controller main remote controller central control remote controller and the interface p c board of the outdoor unit a check display lcd remote controller or 7 segment display on the outdoor interface p c board to display the operation is provided therefore the operation status can be known using this self diagnosis function a trouble or position with trouble of the air conditioner can be found as shown in the table below 56
- The following list shows each check code find the check contents from the list according to part to be checked 56
- Error detected by tcc link central control device 58
- 3 troubleshooting by check display on remote controller 59
- 3 2 in case of tcc link central control remote controller tcb sc642tle2 60
- Confirmation and check 60
- Confirmation of error history 60
- Unit no display alarm display 60
- 4 check code and check position displayed on the remote controller and outdoor unit 7 segment display of interface 61
- 1 all stop only in case of the header unit the follower unit continues operation 64
- Mg sw magnet switch ocr over current relay 65
- Mg sw magnet switch ocr over current relay 66
- Error detected by ai net central control device 72
- Error detected by tcc link central control device 72
- These errors are concerned to communication of remote controllers a b and central system ai net x y and the main remote controller displays e01 e02 e03 e09 or e18 in some cases and displays none in other cases according to the contents 72
- 4 1 cautions when servicing for compressor 73
- 4 2 how to check inverter output 73
- 4 3 how to check resistance of compressor winding 73
- 4 4 how to check the external fan motor 73
- 5 diagnosis procedure for each check code 74
- Cause of operation 74
- Check code 74
- Check code name 74
- Communication error between indoor and remote controller detected at remote controller side 74
- Current code ai net 74
- Remote controller inter unit cable error 2 indoor power error 3 indoor p c board error 4 remote controller address setup error 5 remote controller p c board error 74
- Communication error between indoor and remote controller detected at indoor side 75
- E03 97 75
- It is not displayed on 7 segment display of the central control controller 75
- Remote controller sending error 75
- This error is detected when the indoor unit cannot receive a signal from the remote controller check communication cables of the remote controllers a and b as communication is impossible this check code e03 is not displayed on the main remote controller it is displayed on tcc link central controller 75
- Cause of operation 76
- Check code 76
- Check code name 76
- Current code ai net 76
- E04 04 76
- For details refer to troubleshooting in test operation 76
- Indoor outdoor communication circuit error detected at indoor side 76
- Power of outdoor unit was firstly turned on 2 connection error of communication line between indoor and outdoor 3 end terminal resistance setup error on communication between indoor and outdoor 4 address setup error 5 switch setup error of wall type p c board 76
- Cause of operation 77
- Check code 77
- Check code name 77
- Communication lines u1 u2 connection error between indoor and outdoor 2 connector connection error of communication for indoor p c board 3 connector connection error of communication for outdoor i f board 4 power supply of indoor unit is power turned on 77
- Current code7 ai net 77
- Decreased number of indoor units 77
- E06 04 77
- Note 1 when signal is not sent for a certain period from the indoor unit which has used to send signals normally e06 is displayed 77
- Sub code no of indoor units which received signals normally 77
- Indoor outdoor communication circuit error detected at outdoor side 78
- Cause of operation 79
- Check code 79
- Check code name 79
- Current code ai net 79
- Duplicated indoor addresses 79
- Duplicated master remote controller 79
- E08 96 79
- E09 99 79
- Indoor addresses are duplicated 2 switch setup error of wall type p c board 79
- Setup of master remote controller is duplicated 79
- Sub code duplicated indoor address 79
- Using a main remote controller rbc amt32e check the setup item codes dn code 12 13 and 14 when there is no address duplication check to the following flowchart 79
- Automatic address start error 80
- Cause of operation 80
- Check code 80
- Check code name 80
- Communication line connection error between indoor and outdoor 2 indoor power system error 3 noise from surrounding devices 4 power failure 5 indoor p c board error 80
- Current code ai net 80
- Disconnect connector connection of u1 u2 u3 and u4 80
- E12 42 80
- E15 42 80
- No are u1 u2 u3 and u4 connectors connected 80
- No corresponding indoor unit during automatic address 80
- Set up address again refer to address setup procedure turn on power of outdoor unit again 80
- Sub code 01 communication between indoor and outdoor 02 communication between outdoor units 80
- When indoor automatic address started other refrigerant circuit system was setting automatic address 2 when outdoor automatic address started the indoor automatic address was being set sub code 02 80
- 1 setup of no detection of capacity over 81
- Cause of operation 81
- Check code 81
- Check code name 81
- Connected indoor units capacity over 81
- Current code ai net 81
- E16 89 81
- Sub code 00 capacity over 49 to 64 of connected units 81
- There are 48 or more connected indoor units 2 capacity over of total connected indoor units 3 incorrect setup of indoor outdoor capacity 81
- Turn sw09 bit 2 on i f p c board of header outdoor unit to on usually off 81
- Cause of operation 82
- Check code 82
- Check code name 82
- Communication error between indoor header and follower 82
- Current code ai net 82
- E18 97 99 82
- Regular communication between indoor header and follower is unavailable 2 switch setup error of wall type p c board 82
- Cause of operation 83
- Check code 83
- Check code name 83
- Current code ai net 83
- E19 96 83
- E20 42 83
- Header outdoor units quantity error 83
- Misconnection of inter unit cable between indoor and outdoor 2 outdoor i f p c board error 83
- Reference an outdoor unit connected with communication wires u1 u2 between indoor and outdoor is the header unit 83
- Separate the wire between lines according to address setup method 83
- Sub code 00 no header unit 02 two or more header units 83
- Sub code 01 connection of outdoor in other line 02 connection of indoor unit in other line 83
- Unit connected to other line during automatic address 83
- When starting automatic indoor address a device in other line is connected 83
- Cause of operation 84
- Check code 84
- Check code name 84
- Communication sending error between outdoor units 84
- Current code ai net 84
- E23 15 84
- Inter unit cable connection error between outdoor units 2 communication connector connection error between outdoor units i f p c board error 3 end terminal resistance setup error between outdoor units 84
- 1 how to clear the error 85
- Addresses are duplicated by manual setup of outdoor address 85
- Cause of operation 85
- Check code 85
- Check code name 85
- Current code ai net 85
- Decrease of connected outdoor units 85
- Do not set up outdoor address manually 85
- Duplicated follower outdoor address setup 85
- E25 15 85
- E26 15 85
- Outdoor unit backup setup 2 outdoor power error 3 communication line connection error between outdoor units 4 connector connection error for communication 5 outdoor i f p c board error 85
- Set sw01 sw02 sw03 on i f p c board of header unit to 2 16 1 and push sw04 for 5 seconds or more 7 segment display er cl 85
- Sub code no of outdoor units which received signals normally 85
- An error occurred on the follower unit check the check code of follower unit on 7 segment display on i f p c board of follower unit and then check according to diagnose procedure for each check code how to specify the follower outdoor unit in which error occurred if pushing sw04 for 1 second or more under condition that e28 is displayed on 7 segment display of the header unit the fan of the outdoor which stopped due to occurrence of error starts rotating when pushing sw05 singly the fan operation is cleared 86
- E28 d2 86
- E31 cf 86
- Follower outdoor unit error 86
- If the fan ipdu is abnormal be sure to check the voltage output on the fan power supply p c board 86
- Ipdu communication error 86
- Ipdu1 error 02 ipdu2 error 03 ipdu1 2 error 04 fan ipdu error 05 ipdu1 fan ipdu error 06 ipdu2 fan ipdu error 07 all ipdu error or communication line error between ipdu i f p c boards or outdoor i f p c board error 86
- Sub code 86
- Sub code detected outdoor unit no 86
- Cause of operation 87
- Check code 87
- Check code name 87
- Current code ai net 87
- F01 0f 87
- F02 0d 87
- Indoor tc2 sensor error 87
- Indoor tcj sensor error 87
- Tc2 sensor open short 87
- Tcj sensor open short 87
- Are characteristics of tc1 sensor resistance value normal 88
- Check indoor main p c board defect replace 88
- Correct connection of connector 88
- F03 93 88
- F04 19 88
- F05 a1 88
- F06 18 88
- Indoor tc1 sensor error 88
- Indoor unit temperature sensor characteristics see characteristics 2 88
- Is tc1 sensor connector cn100 brown on indoor p c board normally connected 88
- Replace tc1 sensor 88
- Td1 sensor error 88
- Td2 sensor error 88
- Te1 sensor error 88
- This error code means detection of open short of td1 sensor check disconnection of circuit for connection of connector td1 sensor cn502 white and characteristics of sensor resistance value refer to outdoor unit temperature sensor characteristics if sensor is normal replace outdoor i f p c board 88
- This error code means detection of open short of td2 sensor check disconnection of circuit for connection of connector td2 sensor cn503 pink and characteristics of sensor resistance value refer to outdoor unit temperature sensor characteristics if sensor is normal replace outdoor i f p c board 88
- This error code means detection of open short of te1 sensor check disconnection of circuit for connection of connector te1 sensor cn505 green and characteristics of sensor resistance value refer to outdoor unit temperature sensor characteristics if sensor is normal replace outdoor i f p c board 88
- F07 18 89
- F08 1b 89
- F10 0c 89
- F12 a2 89
- Indoor ta sensor error 89
- This error code means detection of open short of ta sensor check disconnection of circuit for connection of connector ta sensor cn104 white and characteristics of sensor resistance value refer to outdoor unit temperature sensor characteristics if sensor is normal replace indoor p c board 89
- This error code means detection of open short of tl sensor check disconnection of circuit for connection of connector tl sensor cn521 white and characteristics of sensor resistance value refer to outdoor unit temperature sensor characteristics if sensor is normal replace outdoor i f p c board 89
- This error code means detection of open short of to sensor check disconnection of circuit for connection of connector to sensor cn507 yellow and characteristics of sensor resistance value refer to outdoor unit temperature sensor characteristics if sensor is normal replace outdoor i f p c board 89
- This error code means detection of open short of ts1 sensor check disconnection of circuit for connection of connector ts1 sensor cn504 white and characteristics of sensor resistance value refer to outdoor unit temperature sensor characteristics if sensor is normal replace outdoor i f p c board 89
- Tl sensor error 89
- To sensor error 89
- Ts1 sensor error 89
- Cause of operation 90
- Check code 90
- Check code name 90
- Current code ai net 90
- F13 43 90
- F15 18 90
- Igbt built in sensor error in a3 ipdu 90
- Misinstallation and misconnection of te1 sensor and tl sensor 2 resistance characteristics error of te1 sensor and tl sensor 3 outdoor p c board i f error 90
- Outdoor temp sensor miscabling te1 tl 90
- Sub code 01 compressor 1 side 02 compressor 2 side 90
- Th sensor error 90
- This error code means igbt built in temperature sensor error check connection of connectors cn06 on ipdu p c board and cn600 on i f p c board if sensor is normal replace ipdu p c board 90
- F16 43 91
- Outdoor pressure sensor miscabling pd ps 91
- F23 43 92
- F24 43 92
- It is output voltage error of pd sensor check disconnection of connection of connector pd sensor cn501 circuit and output voltage of sensor if the sensor is normal replace outdoor i f p c board 92
- Pd sensor error 92
- Ps sensor error 92
- Cause of operation 93
- Check code 93
- Check code name 93
- Current code ai net 93
- F29 12 93
- F31 1c 93
- If eeprom was not inserted when power was turned on or it is absolutely impossible to read write eeprom data the automatic address mode is repeated in this case 97 error is displayed on ai net central controller 93
- Indoor other error 93
- Indoor p c board error eerom error 93
- Outdoor eeprom error 93
- Outdoor unit power error voltage noise etc 2 outdoor i f p c board error 93
- This error is detected during operation of air conditioner of ic10 non volatile memory eeprom on indoor unit p c board replace service p c board 93
- Compressor breakdown 94
- Details of compressor power connecting section 94
- H01 1f 94
- Cause of operation 95
- Check code 95
- Check code name 95
- Compressor error lock 95
- Current code ai net 95
- H02 1d 95
- Outdoor unit power line error 2 compressor circuit system error 3 compressor error 4 refrigerant stagnation in compressor shell 5 ipdu p c board error 95
- Sub code 01 compressor 1 side 02 compressor 2 side 95
- Current detective circuit system error 96
- H03 17 96
- Sub code 01 compressor 1 side 02 compressor 2 side 96
- Case thermo circuit error 2 i f p c board error 3 service valve closed 4 outdoor pmv clogging 5 sv4 valve leak coil misinstallation 6 4 way valve error 7 compressor error 8 refrigerant shortage 97
- Cause of operation 97
- Check code 97
- Check code name 97
- Compressor 1 case thermo operation 97
- Compressor 2 case thermo operation 97
- Current code ai net 97
- H04 44 97
- H14 44 97
- Cause of operation 98
- Check code 98
- Check code name 98
- Current code ai net 98
- H06 20 98
- Low pressure protective operation 98
- Service valve close 2 ps sensor error 3 sv2 sv4 circuit error 4 miscabling of communication between indoor and outdoor 5 indoor outdoor fan and condenser error 6 indoor outdoor pmv clogging 7 indoor outdoor heat exchanger clogging 8 refrigerant shortage 98
- H07 d7 99
- Oil level down detection protection 99
- Reference when refrigerant stagnates in compressor shell the oil level shortage may be judged 99
- 2 clogging check for sv3d valve of oil return circuit from oil separator 100
- A leakage check for sv3a valve for multiple outdoor unit system 100
- A oil return circuit 100
- B clogging check for sv3d valve 100
- B leakage check for sv3c valve 100
- C clogging check for sv3b valve for multiple outdoor unit system 100
- D clogging for sv3e valve 100
- Reference 100
- 3 check for solenoid valve of outdoor unit for multiple outdoor unit system 101
- A clogging check for oil equalization circuit 101
- A clogging check for sv3a valve 101
- B leakage check for sv3c valve 101
- Criterion 101
- Drive the outdoor unit drive both compressors in the unit after driving for 10 minutes check temperature of tk1 and tk2 sensors and temperature of oil equalization circuit capillary 101
- In the figure 101
- In the figure were raised 101
- Tk1 tk2 td1 td2 temperature approx 10 to 30 c oil equalization capillary tubes should be higher sufficiently than outside air temperature and suction temperature if temperature is low a malfunction of capillary strainer or check valve is considered repair the defective parts 101
- While outdoor unit is operating set up sw01 02 03 2 1 3 to 7 segment display hr 2 and push sw04 for 2 seconds or more set up sw02 4 and turn on sv3a valve 7 segment display hr 3a if temperature is low at secondary side of the valve or it does not change clogging of valve or check valve is considered 101
- While outdoor unit is operating set up sw01 02 03 2 1 3 to 7 segment display hr 2 and push sw04 for 2 seconds or more set up sw02 6 and turn on sv3c valve 7 segment display hr 3c if temperature does not change up clogging of valve or strainer is considered 101
- Circuit 102
- Cn514 black 102
- Cn515 green 102
- Cn516 red 102
- Cn523 yellow 102
- Connector 102
- H08 d4 102
- H16 d7 102
- Oil level detective temperature sensor error 102
- Sub code 01 tk1 sensor error 02 tk2 sensor error 03 tk3 sensor error 04 tk4 sensor error 102
- The detected error is an oil level detective temperature sensor error check disconnection of the wiring and resistance value of the sensor if the sensors are normal replace the outdoor i f p c board 102
- Tk1 temperature detective circuit error sub code 01 102
- Cause of operation 103
- Check code 103
- Check code name 103
- Current code ai net 103
- Detachment of tk2 sensor miscabling characteristics error of resistance value 2 oil equalization circuit error check valve capillary clogging strainer clogging 3 refrigerant stagnation in compressor shell 103
- H16 d7 103
- Oil level detective circuit system error sub code 02 103
- Cause of operation 104
- Check code 104
- Check code name 104
- Current code ai net 104
- Detachment of tk3 sensor miscabling characteristics error of resistance value 2 error of sv3c valve circuit periphery check capillary clogging strainer clogging 3 refrigerant stagnation in compressor shell 104
- H16 d7 104
- Tk3 temperature detective circuit error sub code 03 104
- Cause of operation 105
- Check code 105
- Check code name 105
- Current code ai net 105
- Detachment of tk4 sensor miscabling characteristics error of resistance value 2 check clogging and malfunction of sv3e valve circuit 3 oil equalization circuit error check capillary clogging strainer clogging 4 refrigerant stagnation in compressor shell 105
- H16 d7 105
- Tk4 temperature detective circuit error sub code 04 105
- Check the connection changing of the remote controller after the connection has been changed 2 if the group configuration and address are normal when power has been turned on the mode automatically shifts to address setup mode re setup of address refer to address setup 106
- Duplicated indoor header units 106
- Duplicated indoor units with priority displayed on indoor unit with priority 106
- Duplicated setup of outdoor line address 106
- L03 96 106
- L04 96 106
- L05 96 106
- This check code is displayed on the set indoor unit when setup of indoor unit with priority is duplicated priority setup with two or more units is not available choose one prior unit in one refrigerant circuit system 106
- Cause of operation 107
- Check code 107
- Check code name 107
- Current code ai net 107
- Duplicated indoor units with priority displayed on the indoor unit other than one with priority and on the outdoor unit 107
- Group line in individual indoor unit 107
- L06 96 107
- L07 99 107
- Sub code no of indoor units with priority 107
- The group line is connected in the individual indoor unit 107
- Two or more indoor units with priority are duplicated 107
- When indoor unit with priority is duplicated this check code is displayed on the unit other than the setup indoor unit and outdoor unit as only one indoor unit with priority is valid change the setup 107
- Indoor capacity unset 108
- Indoor group address unset 108
- L08 99 108
- L09 46 108
- Note this code is displayed when the power is turned on at the first time after installation because the address is not yet set up 108
- Duplicated central control addresses 109
- I f p c board a ssy service for the outdoor unit is common to this series a setup for model selection different from that for p c board with trouble is necessary set up a model based upon the p c board a ssy exchange procedure 109
- L10 88 109
- L20 98 109
- L28 46 109
- Outdoor capacity unset 109
- Quantity over of connected outdoor units 109
- Ipdu quantity error 110
- L29 cf 110
- Sub code 01 ipdu1 error 02 ipdu2 error 03 ipdu1 2 error 04 fan ipdu error 05 ipdu1 fan ipdu error 06 ipdu2 fan ipdu error 07 all ipdu error or disconnection of communication line between ipdu i f p c board or outdoor i f p c board error 110
- Check outdoor i f p c board 111
- Extended ic error 111
- Interlock in indoor unit from outside 111
- Is there any trouble of outdoor unit power supply check power voltage and line check auxiliaty noise etc 111
- L30 b6 111
- Cause of operation 112
- Check code 112
- Check code name 112
- Current code ai net 112
- Discharge temp td1 error 112
- P03 1e 112
- Service valve of outdoor unit closed 2 outdoor pmv error 3 td sensor error 4 refrigerant shortage clogging of refrigerant circuit system 5 4 way valve error 6 sv4 circuit leakage misinstallation 112
- Actuation of high pressure sw 113
- P04 21 113
- Check the phase power line of outdoor unit check error of outdoor i f p c board check there is no looseness etc of terminal 115
- Heat sink overheat error 115
- Open phase negative phase 115
- P05 af 115
- P07 1c 115
- Sub code 01 compressor 1 side 02 compressor 2 side 115
- Cause of operation 116
- Check code 116
- Check code name 116
- Current code ai net 116
- Fan motor connector error 2 fan motor error 3 indoor p c board error 4 cross flow fan bearing error 116
- Indoor fan motor error 116
- P12 11 116
- Cause of operation 117
- Check code 117
- Check code name 117
- Current code ai net 117
- Outdoor liquid back detection error 117
- P13 47 117
- Pmv1 pmv2 error 2 pd sensor ps sensor error 3 clogging of sv2 circuit 4 clogging of sv3b circuit balance pipe 5 leakage of main discharge pipe 6 outdoor i f p c board error 117
- Gas leak detection ts condition sub code 01 118
- P15 ae 118
- Cause of operation 119
- Check code 119
- Check code name 119
- Current code ai net 119
- Gas leak detection td condition sub code 02 119
- Outdoor unit service valve closed 2 outdoor pmv error 3 td sensor error 4 sv4 circuit error 5 refrigerant shortage clogging refrigerant circuit 119
- P15 ae 119
- Cause of operation 120
- Check code 120
- Check code name 120
- Current code ai net 120
- Discharge temp td2 error 120
- Outdoor unit service valve closed 2 outdoor pmv error 3 td sensor error 4 refrigerant shortage clogging of refrigerant circuit 5 4 way valve error 6 sv4 circuit leakage misinstallation 120
- P17 bb 120
- Cause of operation 121
- Check code 121
- Check code name 121
- Current code ai net 121
- P19 08 121
- Sub code detected outdoor unit no 121
- Way valve error 2 ts1 sensor te1 sensor error 3 pd sensor ps sensor error 4 te sensor tl sensor misconnection 121
- Way valve operation error 121
- Cause of operation 122
- Check code 122
- Check code name 122
- Current code ai net 122
- High pressure protective operation 122
- P20 22 122
- Pd sensor error 2 service valve closed 3 indoor outdoor fan error 4 indoor outdoor pmv clogging 5 indoor outdoor heat exchanger clogging 6 sv2 circuit error 7 sv4 circuit error 8 sv5 circuit error 9 outdoor i f p c board error 10 operation error of check valve of main discharge pipe 11 refrigerant overcharge 122
- Cause of operation 124
- Check code 124
- Check code name 124
- Current code ai net 124
- Fan lock 2 fan ipdu p c board error 3 overload cause 4 external cause such as blast 5 fan ipdu power p c board error 124
- Outdoor fan ipdu error 124
- P22 1a 124
- Sub code 0 igbt short circuit 1 position detect circuit error 3 motor lock error 4 motor current error detected c th sensor error heat sink overheat d th sensor error e vdc error 124
- G tr short circuit protection error 125
- P26 14 125
- Sub code 01 compressor 1 side 02 compressor 2 side 125
- Cable connector connection error 2 compressor error 3 ipdu p c board error 126
- Cause of operation 126
- Check code 126
- Check code name 126
- Compressor position detective circuit error 126
- Current code ai net 126
- Other indoor error group follower unit error 126
- Other indoor unit in the group is abnormal 126
- P29 16 126
- P31 47 126
- Sub code 01 compressor 1 side 02 compressor 2 side 126
- When the header unit of the group detected e03 l03 l07 l08 error the follower unit of the group displays p31 error and stops there are no check code display and alarm record of the main remote controller 126
- Ai net communication line error 127
- Cause of operation 127
- Check code 127
- Check code name 127
- Current code ai net 127
- 5 1 indoor unit 128
- Characteristic 1 128
- Characteristic 2 128
- Temperature sensor characteristics 128
- 1 1 case of main sub remote controller connected 129
- 1 indoor controller block diagram 129
- Configuration of control circuit 129
- 1 2 case of wireless remote controller kit connected 130
- Indoor unit 130
- Max 8 units are connectable 1 in group connection mount the central control remote controller to group header unit 130
- How to replace main parts 131
- If keeping the power on is absolutely unavoidable while doing a job such as inspecting the circuitry wear rubber gloves to avoid contact with the live parts 131
- Warning 131
- 1 indoor unit 132
- Cautions in reassemblin 133
- 1 readout of the setup data from eeprom 139
- Case 1 139
- Case 2 139
- Replacement of service indoor p c board 139
- Requirement when replacing the service indoor p c board assembly 139
- 2 replacement of service p c board 140
- Minimum requirements for code no 140
- Case 1 141
- Case 2 141
- Method of dip switch setting 141
- P c board parts layout drawing 141
- 3 3 writing of the setup contents to eeprom 142
- Code no table please record the objective unit data at field 143
- Indoor unit capacity code no 11 143
- Initial value of eeprom installed on the supplied service p c board 143
- 1 indoor unit 144
- 205 233 210 144
- 214 213 144
- 225 201 208 220 238 144
- Detail drawi ng a 144
- Exploded views and parts list 144
- Indoor unit part e 145
- 2 indoor unit 146
- 206 207 146
- 212 213 146
- 239 223 146
- Detail drawing a 146
- Indoor unit part e 147
- 205 233 210 148
- 214 213 148
- 225 201 208 220 238 148
- 3 indoor unit 148
- Detail drawi ng a 148
- Indoor unit part e 149
- 206 207 150
- 212 213 150
- 4 indoor unit 150
- Detail drawing a 150
- Indoor unit part e 151
Похожие устройства
- Toshiba MMK-AP0243H Каталог кондиционеров Toshiba
- Toshiba MMK-AP0183H Инструкция по эксплуатации
- Toshiba MMK-AP0183H Каталог кондиционеров Toshiba
- Toshiba MMK-AP0153H Инструкция по эксплуатации
- Toshiba MMK-AP0153H Каталог кондиционеров Toshiba
- Toshiba MMU-AP0094MH-E Инструкция по эксплуатации
- Toshiba MMU-AP0094MH-E Брошюра
- Toshiba MMU-AP0184MH-E Инструкция по эксплуатации
- Toshiba MMU-AP0184MH-E Брошюра
- Toshiba MMU-AP0074MH-E Инструкция по эксплуатации
- Toshiba MMU-AP0074MH-E Брошюра
- Toshiba RBC-AMS51E-EN Инструкция по эксплуатации
- Toshiba MMU-AP0124MH-E Инструкция по эксплуатации
- Toshiba MMU-AP0124MH-E Брошюра
- Toshiba MMU-AP0154MH-E Инструкция по эксплуатации
- Toshiba MMU-AP0154MH-E Брошюра
- Toshiba MMU-AP0272H Инструкция по эксплуатации
- Toshiba MMU-AP0272H Брошюра
- Toshiba MMU-AP0242H Инструкция по эксплуатации
- Toshiba MMU-AP0242H Брошюра