–22–
L05 — — 96 SIM Duplicated indoor units with priority (Displayed in indoor unit with priority) I/F
L06 L06 No. of indoor units with priority 96 SIM
Duplicated indoor units with priority (Displayed in unit other than indoor unit
with priority)
I/F
L07 — — 99 SIM Group line in individual indoor unit Indoor unit
L08 L08 — 99 SIM Indoor unit group/Address unset Indoor unit, I/F
L09 — — 46 SIM Indoor unit capacity unset Indoor unit
L10 L10 — 88 SIM Outdoor unit capacity unset I/F
L17 — — 46 SIM Outdoor unit type mismatch error I/F
L20 — — 98 SIM Duplicated central control addresses AI-NET, Indoor unit
L26 L26 Number of heat storage units connected 46 SIM Too many heat storage units connected I/F
L27 L27 Number of heat storage units connected 46 SIM Error in number of heat storage units connected I/F
L28 L28 — 46 SIM Too many outdoor units connected I/F
L29 L29 Number of IPDU (*1) CF SIM No. of IPDU error I/F
L30 L30 Detected indoor unit address b6 SIM Indoor unit outside interlock Indoor unit
— L31 — — — Extended I/C error I/F
P01 — — 11 ALT Indoor fan motor error Indoor unit
P03 P03 — 1E ALT Discharge temp. TD1 error I/F
P04 P04
01:Comp. 1 side
02:Comp. 2 side
03:Comp. 3 side
21 ALT High-pressure SW system operation IPDU
P05 P05
00:
01:Comp. 1 side
02:Comp. 2 side
03:Comp. 3 side
AF ALT
Phase missing detection/Power failure detection
Inverter DC voltage error (comp.)
Inverter DC voltage error (comp.)
Inverter DC voltage error (comp.)
I/F
P07 P07
01:Comp. 1 side
02:Comp. 2 side
03:Comp. 3 side
IC ALT Heat sink overheat error IPDU, I/F
P09 P09 Detected heat storage address 47 ALT No heat storage unit water error Heat storage unit
P10 P10 Detected indoor unit address Ob ALT Indoor unit overflow error Indoor unit
P12 — — 11 ALT Indoor unit fan motor error Indoor unit
P13 P13 — 47 ALT Outdoor liquid back detection error I/F
P15 P15
01:TS condition
02:TD condition
AE ALT Gas leak detection I/F
P17 P17 — bb ALT Discharge temp. TD2 error I/F
P18 P18 — E2 ALT Discharge temp. TD3 error I/F
P19 P19 Detected outdoor unit number O8 ALT 4-way valve inverse error I/F
P20 P20 — 22 ALT High-pressure protective operation I/F
P22 P22
0*:IGBT circuit
1*:Position detective circuit error
3*:Motor lock error
4*:Motor current detection
C*:TH sensor error
D*:TH sensor error
E*:Inverter DC voltage error (outdoor unit
fan)
1A ALT
Outdoor unit fan IPDU error
Note: Ignore 0 to F displayed in “*” position.
IPDU
P26 P26
01:Comp. 1 side
02:Comp. 2 side
03:Comp. 3 side
14 ALT G-TR short protection error IPDU
Check code Wireless remote controller
Check code name Judging device
Wired remote
controller display
Outdoor unit 7-segment display
AI-NET central
control display
Sensor block display of receiving unit
Auxiliary code Operation Timer Ready Flash
43-EN 44-EN
Содержание
- Accessory parts p.2
- Contents p.2
- Test run 7 p.2
- Adoption of new refrigerant p.2
- Specifications 4 p.2
- Selection of installation place p.2
- Refrigerant piping 2 p.2
- Precautions for safety p.2
- Please read this installation manual carefully before installing the air conditioner p.2
- Original instruction p.2
- Maintenance 8 p.2
- Installation p.2
- Generic denomination air conditioner p.2
- Electrical connection 3 p.2
- Duct design 1 p.2
- Drain piping p.2
- Troubleshooting 9 p.2
- Definition of qualified installer or qualified service person the air conditioner must be installed maintained repaired and removed by a qualified installer or qualified service person when any of these jobs is to be done ask a qualified installer or qualified service person to do them for you a qualified installer or qualified service person is an agent who has the qualifications and knowledge described in the following table p.2
- This air conditioner uses r410a an environmentally friendly refrigerant p.2
- Thank you for purchasing this toshiba air conditioner please read carefully through these instructions that contain important information which complies with the machinery directive directive 2006 42 ec and ensure that you understand them after completing the installation work hand over this installation manual as well as the owner s manual provided to the user and ask the user to keep them in a safe place for future reference p.2
- Applicable controls 5 p.2
- Warning indications on the air conditioner unit p.3
- Warning p.3
- Stop the unit before the servicing p.3
- Open the service valves before the operation otherwise there might be the burst p.3
- Caution p.3
- Burst hazard p.3
- Installation p.4
- The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual p.4
- Selection of installation location p.4
- Refrigerant piping p.4
- Precautions for safety p.4
- General p.4
- Electrical wiring p.4
- Warning p.4
- Caution p.5
- Accessory parts p.5
- Selection of installation place p.6
- Installation under high humidity atmosphere p.6
- Avoid installing in the following places p.6
- Installation space p.7
- Installation p.7
- Filter cleaning sign term setting p.7
- External dimensions p.7
- Caution p.7
- Mount the filter rail so that the hooks fit into the corresponding holes note that the upper and lower filter rails are not identical p.8
- Installation of indoor unit p.8
- Installation of hanging bolt p.8
- Changing from back air intake to under air intake p.8
- Caution p.8
- Treatment of ceiling p.8
- Slide and push the filters until it stop p.8
- Remove the suction board cover attached to the bottom and screw it to the back of unit p.8
- Remove the filters on back of unit p.8
- Mounting filter rails and filters p.8
- Mount the supplied rail to the bottom then set the filter p.8
- Mount the filter stopper p.8
- Pipe material size and insulator p.9
- Gravitational drainage p.9
- Drain up p.9
- Drain piping p.9
- Connecting drain pipe p.9
- Check the draining p.10
- Heat insulating process p.10
- Connecting method of the duct p.10
- Caution p.10
- When the electrical and wiring work has not been completed p.10
- When the electrical and wiring work has been completed p.10
- High tap 30pa standard filter pressure loss p.11
- High tap 30pa p.11
- High tap 120pa p.11
- High tap 100pa p.11
- Fan characteristics p.11
- External static pressure pa p.11
- Upper limit of external static pessure 120pa lower limit of external static pessure 120pa p.11
- En 20 en p.11
- Upper limit of external static pessure 120pa p.11
- Ap0306 type ap0336 type ap0486 ap0566 type p.11
- Standard filter pressure loss p.11
- Ap0076 type ap0096 ap0126 type ap0156 ap0186 type ap0246 ap0276 type p.11
- Lower limit of external static pessure 120pa p.11
- Air volume p.11
- Low tap 120pa high tap 100pa p.11
- 480 580 680 780 880 980 p.11
- Low tap 120pa p.11
- 300 400 500 600 700 800 p.11
- High tap 80pa p.11
- 1200 1400 1600 1800 2000 2200 2400 2600 p.11
- High tap 65pa p.11
- 1100 1300 1500 1700 1900 2100 2300 2500 p.11
- High tap 50pa p.11
- High tap 40pa p.11
- Duct design p.12
- Arrangement p.12
- Ap0246 ap0276 ap0306 ap0366 ap0486 ap0566 p.12
- Ap0156 ap0186 p.12
- Ap0076 ap0096 ap0126 p.12
- Caution p.13
- Refrigerant piping p.13
- Refrigerant amount to be added p.13
- Projection margin in flaring b unit mm p.13
- Pipe size p.13
- Permissible piping length and p.13
- Open the valve fully p.13
- Height difference p.13
- Gas leak check p.13
- Flaring diameter size a unit mm p.13
- Flaring p.13
- Evacuation p.13
- Connecting refrigerant piping p.13
- Indoor unit power supply p.14
- Heat insulation process p.14
- Electrical connection p.14
- Caution p.14
- Warning p.14
- Specifications p.14
- Power supply wire and communication wires p.14
- Wiring example p.15
- Wiring between indoor unit and outdoor unit p.15
- The remote controller wire communication line and ac 220 240 v wires cannot be parallel to contact each other and cannot be stored in the same conduits if doing so a trouble may be caused on the control system due to noise or other factor p.15
- Remote controller wiring p.15
- Power supply p.15
- Control wiring central controller wiring p.15
- Communication line p.15
- Caution p.15
- An outdoor unit connected with control wiring between indoor and outdoor units wire becomes automatically the header unit p.15
- 2 core with polarity wires are used for the control wiring between indoor unit and outdoor unit and central controller wiring to prevent noise trouble use 2 core shield wire the length of the communication line means the total length of the inter unit wire length between indoor and outdoor units added with the central control system wire length p.15
- 2 core with non polarity wire is used for wiring of the remote controller wiring and group remote controllers wiring p.15
- Basic procedure for changing p.16
- Applicable controls p.16
- Wire connection p.16
- Settings p.16
- Remote controller wiring p.16
- Push and hold button and temp button simultaneously for 4 seconds or more after a while the display flashes as shown in the figure confirm that the code no is 01 p.16
- Settings p.17
- External static pressure p.17
- Test run p.18
- Maintenance p.19
- Troubleshooting p.20
- Confirmation of error log p.20
- Confirmation and check p.20
- The following list shows each check code find the check contents from the list according to part to be checked in case of check from indoor remote controller see wired remote controller display in the list in case of check from outdoor unit see outdoor unit 7 segment display in the list in case of check from ai net central control remote controller see ai net central control display in the list in case of check from indoor unit with a wireless remote controller see sensor block display of receiving unit in the list lighting flashing goes off ai net artificial intelligence ipdu intelligent power drive unit alt flashing is alternately when there are two flashing led sim simultaneous flashing when there are two flashing led p.21
- On the wired remote controller central control remote controller and the interface p c board of the outdoor unit i f a check display lcd remote controller or 7 segment display on the outdoor interface p c board to display the operation is provided therefore the operation status can be known using this self diagnosis function a trouble or position with error of the air conditioner can be found as shown in the following table p.21
- Check method p.21
- Check code list p.21
- Error detected by tcc link central control device p.24
- Specifications p.25
- Declaration of conformity p.25
- Warnings on refrigerant leakage p.26
- Note 3 p.26
- Note 2 p.26
- Note 1 p.26
- Important p.26
- Check of concentration limit p.26
- Requirement p.27
- Prior to delivery to the customer check the address and setup of the indoor unit which has been installed in this time and fill the check sheet following table data of four units can be entered in this check sheet copy this sheet according to the no of the indoor units if the installed system is a group control system use this sheet by entering each line system into each installation manual attached to the other indoor units p.27
- Indoor unit setup check sheet p.27
- Confirmation of indoor unit setup p.27
Похожие устройства
-
Toshiba MMK-AP0074MH-EИнструкция по эксплуатации -
Toshiba MMK-AP0094MH-EИнструкция по эксплуатации -
Toshiba MMK-AP0124MH-EИнструкция по эксплуатации -
Toshiba MMD-AP0156BH-EБрошюра -
Toshiba MMD-AP0156BH-EИнструкция по эксплуатации -
Toshiba MMD-AP0126BHP-EИнструкция по эксплуатации -
Toshiba MMC-AP0364H-EБрошюра -
Toshiba MMC-AP0364H-EИнструкция по эксплуатации -
Toshiba MMC-AP0244H-EБрошюра -
Toshiba MMC-AP0244H-EИнструкция по эксплуатации -
Toshiba MMC-AP0274H-EБрошюра -
Toshiba MMC-AP0274H-EИнструкция по эксплуатации