Toshiba MMK-AP0094MH-E — установка и монтаж внутренних и наружных блоков кондиционеров [73/102]

Toshiba MMK-AP0074MH-E [73/102] Wireless remote controller
73
SMMS High-Wall Type
Installation Manual
– 11 –
Installation diagram of Indoor and outdoor units
For the rear left and left
piping
Wall
Insert the cushion
between the indoor unit
and wall, and tilt the indoor
unit for better operation.
Do not allow the drain
hose to get slack.
Cut the
piping hole
sloped
slightly.
Run the drain hose sloped
downward.
The auxiliary piping can be connected to the left, rear left,
rear right, right, bottom right or bottom left.
Right
Rear right
Bottom right
Bottom left
Rear left
100 mm or more
1
7
0
m
m
o
r
m
o
r
e
1
7
0
m
m
o
r
m
o
r
e
Hook
Installation plate
Hook
Shield pipe
A
i
r
f
i
l
t
e
r
(
A
tt
a
c
h
t
o
t
h
e
f
r
o
n
t
p
a
n
e
l
.
)
Remote control
holder
Pan head wood
screw
Wireless remote
control
Before installing the
wireless remote controller
With the remote controller
cover open, load the
batteries supplied
correctly, observing their
polarity.
Wireless remote controller
Cover
Batteries
*1
*
2
Left
Installation space
The indoor unit shall be installed so that its top surface comes at a height of 2 m or more.
Also it must be avoided to put anything on top of the indoor unit.
*1 Reserve space required to install the indoor unit and for service work.
Keep 100 mm or more for clearance between top plate of the indoor unit and the ceiling surface.
*2 Keep a space more than 300 mm for wiring work at installation of the Flow Selector Unit (FS Unit).
11-EN
SMMS High-Wall Type
Installation Manual
– 12 –
EN
Installation place
A place which provides the spaces around the indoor unit as shown in the above diagram.
A place where there is no obstacle near the air intake and discharge.
A place that allows easy installation of the piping to the outdoor unit.
A place which allows the front panel to be opened.
CAUTION
Direct sunlight to the indoor unit’s wireless receiver should be avoided.
The microprocessor in the indoor unit should not be too close to RF noise sources.
(For details, see the owner’s manual.)
Wireless remote controller
A place where there are no obstacles such as a curtain that may block the signal from the indoor unit.
Do not install the remote controller in a place exposed to direct sunlight or close to a heating source, such
as a stove.
Keep the remote controller at least 1 m apart from the nearest TV set or stereo equipment.
(This is necessary to prevent image disturb-bounces or noise interference.)
The location of the remote controller should be determined as shown below.
(Side view) (Top view)
Remote controller
Reception
range
* : Axial distance
Indoor unit
Remote controller
* 7 m
Indoor unit
5
m
5 m
7
m
7
4
5
°
4
5
°
Reception range