Hytera MD-785 [26/33] Functions and operations
![Hytera MD-785 [26/33] Functions and operations](/views2/1033617/page26/bg1a.png)
21
the icon , with LED ashing orange rapidly). And when a
call is received, the icon
appears.
To exit the Emergency mode, long press the programmed
Emergency key.
Note: Your dealer may set the number of alarm
cycles and alarm duration (None), number of
polite retries and impolite retries (HDC1200),
number of voice cycles, duration of each
transmission and TX interval.
Operation Method for Digital Emergency
Call Only
Operation:
1. Press the programmed Emergency key to go to the Revert
Channel, and the radio displays the icon .
2. If the feature “Alarm with Call to Follow” is enabled, you can
speak into the microphone to make an emergency call when
the radio displays the icon .
3. When the icon
appears, you can receive. And when a
call is received, the icon appears.
4. If the preset Voice Cycles expire, you can hold down the
PTT
key to make the emergency call again (the radio displays the
icon , with red LED glowing). After the emergency call is
transmitted, release the PTT key to receive (the radio displays
icon , with LED ashing orange rapidly). And when a call is
received, the icon appears.
To exit the Emergency mode, long press the programmed
Emergency key.
Note: Your dealer may set the number of voice
cycles, duration of each transmission and TX
interval.
Ignition Sense
The following options are available via the vehicle ignition. You
may ask your dealer to assign any one to your radio.
PTT Disable: The PTT key is enabled or disabled by following
the ignition sense.
Operation:
To enable the PTT key, start the engine; to disable the PTT
key, stop the engine.
Ignition or Switch: The radio powers on or off by following
either the ignition sense or the Power On/Off key.
Operation:
To power on the radio, start the engine or long press the
Power On/Off key; to power it off, stop the engine or press the
Power On/Off key.
Functions and Operations
Содержание
- Dmr mobile radio 1
- Owner s manual 1
- Page 1 1
- X05031 1
- Preface 2
- Alert icons 3
- All call 3
- Function icons 3
- Group call 3
- Instructional icons 3
- Key operation 3
- Private call 3
- Ptt id 3
- Squelch 3
- Term explanation 3
- Copyright information 4
- Disclaimer 4
- Eu regulatory conformance 5
- Fcc regulations 5
- Rf radiation information 5
- Rf radiation profile 5
- Rf radiation safety 5
- Basic operations 9 6
- Call 10 6
- Checking items in the package 2 product overview 3 6
- Contents 6
- Functions and operations 17 6
- Installation 5 6
- Menu navigation 12 6
- Signaling introduction 24 6
- Status indication 7 6
- Troubleshooting 25 care and cleaning 26 optional accessories 27 appendix 28 6
- Checking items in the package 7
- Front panel 8
- Product overview 8
- Rear panel 8
- Product overview 9
- Programmable keys 9
- Installation 10
- Installation tools 10
- Instructions 10
- Installation 11
- Installation steps 11
- Lcd icon 12
- Status icon 12
- Status indication 12
- Led indicator 13
- Operation mode icon 13
- Status indication 13
- Adjusting the volume 14
- Basic operations 14
- Selecting a channel 14
- Selecting a zone 14
- Switching the channel mode 14
- Turning the radio on off 14
- Group call 15
- Private call 15
- Receiving and responding to a private call 15
- Transmitting a group call 15
- Transmitting a private call 15
- All call 16
- Calls on analog channels 16
- Receiving an all call 16
- Receiving and responding to a group call 16
- Transmitting an all call 16
- Contact 17
- Contact list 17
- Manual dial 17
- Menu navigation 17
- Message 17
- New contact 17
- Call logs 18
- Drafts 18
- Menu navigation 18
- New msg 18
- Outbox 18
- Quick text 18
- Menu navigation 19
- Scan list 19
- Scan on off 19
- Settings 19
- Menu navigation 20
- Radio set 20
- Accessories 21
- Device info 21
- Menu navigation 21
- Functions and operations 22
- Home screen 22
- Public address 22
- Emergency 23
- Emergency type 23
- Functions and operations 23
- Monitor 23
- Squelch off 23
- Talk around 23
- Emergency id type 24
- Emergency mode 24
- Functions and operations 24
- Alarm none hdc1200 25
- Alarm with call none hdc1200 25
- Call only hdc1200 25
- Functions and operations 25
- Operationmethodsforanalogemergency 25
- Call only 26
- Functions and operations 26
- Ignition sense 26
- Operationmethodfordigitalemergency 26
- Busy channel lockout 27
- Encrypt 27
- Functions and operations 27
- Pseudo trunking 27
- Scrambler 27
- Time out timer tot 27
- Channel steering 28
- Emergency footswitch 28
- Functions and operations 28
- Mic agc 28
- Hdc1200 29
- Signaling introduction 29
- If the above solutions can not fix your problems or you may have some other queries please contact us or your local dealer for more technical support 30
- Phenomena analysis solution 30
- Troubleshooting 30
- Care and cleaning 31
- Product care 31
- Product cleaning 31
- Optional accessories 32
- Appendix 33
- Input method 33
Похожие устройства
- Samsung P805J Инструкция по эксплуатации
- Philips HR 2870/50 Инструкция по эксплуатации
- Hytera MD-785G Инструкция по эксплуатации
- Panasonic TX-34P250T Инструкция по эксплуатации
- Philips HR 2000/70 Инструкция по эксплуатации
- Hytera PD-785 Инструкция по эксплуатации
- Konica Minolta Dynax 5D Инструкция по эксплуатации
- Hansa FCCW 54136060 Инструкция по эксплуатации
- Philips HR2170/40 Инструкция по эксплуатации
- Hytera PD-785G Инструкция по эксплуатации
- Bernina Bernette E82e Инструкция по эксплуатации
- Philips HR 1342/00 Инструкция по эксплуатации
- Hytera PD-705 Инструкция по эксплуатации
- Soundmax SM-DVD5100-N Инструкция по эксплуатации
- Gorenje EC 55220 AW Инструкция по эксплуатации
- Philips HR 1361/00 Инструкция по эксплуатации
- Hytera PD-705G Инструкция по эксплуатации
- BBK STB105A Инструкция по эксплуатации
- Electrolux ESL 459 Инструкция по эксплуатации
- Gorenje EC 57341 AX Инструкция по эксплуатации
Скачать
Случайные обсуждения