7OPERATION
Technical Dept. - All rights reserved - Reproduction is prohibited
STAGES FOR THE FIRST START-UP TEST
• Make sure you have read and fully understood the contents of this instructions manual.
• Remove all components that could burn from the closed replace rebox and door (instructions and various adhesive labels).
• Remove the stickers from the ceramic glass otherwise the high temperature could melt them and cause irreparable damage to the
glass. In this case the manufacturer will not guarantee the glass.
• Open the front combustion air damper completely using the hook supplied.
• Position small sized and thoroughly dry wood (moisture 15/20%). Light the re on moderate power without heating the structure
excessively. Any smells from processing and/or evaporation residues will be emitted the rst few times the replace is lit and will
disappear after it has been used a few times on full power.
• Do not close the sliding door immediately, but leave it open by about 10 cm so that the wood can burn better and so that any internal
moisture can dry out. When the ame is stable close the door completely.
FUEL
FUEL: Wood
In order to achieve maximum eciency from your product, it is of utmost importance to use wood with adequate characteristics.
One can use wood for heating such as oak-beech-ash-robinia-durmast wood or uncoated pressed wood logs. The latter have a high
caloric value and must be used with caution to avoid overheating that could damage the product.Fuels such as poplar-pine-
linden-chestnut have a low caloric value as the wood is soft. The humidity content is fundamental for all types of wood.
Wood drying time
(e.g. beech)
Moisture
%
Caloric value
Kcal/h
Freshly cut 50 /
3 Months 40 2410
6 Months 35 2700
9 Months 30 2900
12 Months 25 3150
15 Months 20 3400
18 Months 15 3710
21 Months 10 3980
FIGURE 10 - MAXIMUM ADJUSTMENT OF COMBUSTION AIR DAMPER
Содержание
- Care of the manual and how to consult it 3
- Introduction 3
- Revisions to the publication 3
- Symbols used in the manual 3
- Safety precautions 4
- Warnings and warranty conditions 4
- Information 5
- Intended use 5
- Warnings and warranty conditions 5
- Warranty conditions 5
- Exclusions 6
- Warnings and warranty conditions 6
- Spare parts 7
- Warnings and warranty conditions 7
- Warnings for the correct disposal of the product 7
- Installation 9
- Installation foreword 9
- Minimum distances 9
- Foreword 10
- Min 5 metri 10
- Smoke flue 10
- Technical characteristics 11
- Dimensioning 12
- Chimney 13
- Chimney components 13
- Maintenance 13
- External air inlet 14
- Connection to flue 15
- Examples of correct installation 17
- Dimensions and technical characteristics 18
- Forma wood 75 dx sx dimensions sx left version in figure 18
- Dimensions and technical characteristics 19
- Forma wood 95 dx sx dimensions sx left version in figure 19
- Technical dept all rights reserved reproduction is prohibited 19
- Dimensions and technical characteristics 20
- Forma wood t95 dimensions 20
- Dimensions and technical characteristics 21
- Forma wood t50 dimensions 21
- Technical dept all rights reserved reproduction is prohibited 21
- Dimensions and technical characteristics 22
- Technical characteristics 22
- Installation and assembly 23
- Preparation and unpacking 23
- Choice of operating mode 24
- Counterweights unlocking 24
- Forced convection comfort air vf 24
- Installation and assembly 24
- Natural convection comfort air vn 24
- Installation and assembly 25
- Positioning 25
- Height and level adjustment 26
- Installation and assembly 26
- Combustion air inlet 27
- External and internal air inlet 27
- Forced ventilation air inlet 27
- Installation and assembly 27
- Natural ventilation air inlet 27
- Cladding and counter hood assembly 28
- Flue connection 28
- Installation and assembly 28
- Fireplace insulation 29
- Hood ventilation outlets 29
- Installation and assembly 29
- Wooden beam insulation 29
- Do not expect heating efficiency immediately 30
- Operation 30
- Operation test 30
- Start up precautions 30
- Fuel wood 31
- Operation 31
- Stages for the first start up test 31
- First ignition 32
- Operation 32
- Fuel loading 33
- Operation 33
- Combustion control 34
- Operation 34
- Primary air 34
- Door opening switch 35
- Operation 35
- Quick response 35
- Secondary air 35
- Cleaning performed by the user 36
- Cleaning the glass 36
- Maintenance and cleaning 36
- Cleaning performed by a qualified technician 37
- Cleaning the ash 37
- Cleaning the chimney 37
- Cleaning the refractory parts alutec 37
- Maintenance and cleaning 37
Похожие устройства
- MCZ Forma 75 sx Сертификат
- MCZ Forma 75 dx Инструкция по эксплуатации
- MCZ Forma 75 dx Сертификат
- MCZ Forma T95 Инструкция по эксплуатации
- MCZ Forma T95 Сертификат
- MCZ Forma 75 Инструкция по эксплуатации
- MCZ Forma 75 Сертификат
- MCZ Forma T50 Инструкция по эксплуатации
- MCZ Forma T50 Сертификат
- CAS ER JR-15CB LT черные Инструкция по эксплуатации
- CAS ER JR-15CB черные Инструкция по эксплуатации
- MCZ HydroTherm 70 dx Инструкция по эксплуатации
- MCZ HydroTherm 70 dx Сертификат
- CAS ER JR-30CB LT черные Инструкция по эксплуатации
- MCZ HydroTherm E80 Инструкция по эксплуатации
- MCZ HydroTherm E80 Сертификат
- MCZ HydroTherm 70V Инструкция по эксплуатации
- MCZ HydroTherm 70V Сертификат
- CAS ER JR-15CBU черные Инструкция по эксплуатации
- MCZ HydroTherm 80 Инструкция по эксплуатации