MCZ Forma T50 [10/40] Min 5 metri
![MCZ Forma 95 dx [10/40] Min 5 metri](/views2/1336206/page10/bga.png)
min.3,5 metri
AT
(A)
AP
(B)
8
4-FLUE
SMOKE FLUE
FOREWORD
The Chimney Flue chapter has been drawn up with reference to the provisions of European Standards (EN13384 - EN1443 - EN1856 -
EN1457).
The chapter provides indications for installing an ecient and correct smoke ue but is under no circumstances to substitute the
regulations in force, which the qualied technician must be in possession of. Check with local authorities whether there are any restrictive
regulations in force regarding the intake of air for combustion, the smoke extraction system, the ue or the chimney.
The company declines all liability relating to the poor functioning of the boiler if this is due to the use of an insuciently sized ue in
violation of regulations in force.
SMOKE FLUE
The ue or chimney is of great importance for the proper operation of a solid fuel-burning heating appliance with natural draught, as
modern heating appliances have high eciency with cooler ue gasses and consequently less draught, it is therefore essential that the
ue is built up to standard and always kept in perfect working order. A ue that serves a wood-burning appliance must be at least category
T400 (or greater if the appliance requires so) and resistant to soot res. Smoke must be extracted through a single ue made of insulated
steel (A) or an existing ue that complies with the intended use (B).
A simple air shaft in cement must be suitably lined. In both solutions there must be an inspection cap (AT) and/or inspection hatch (AP)
- FIG.1.
It is prohibited to connect more than one wood/pellet or any other type of appliance (vent cowling...) to the same ue.
FIGURE 1 - SMOKE FLUE
Содержание
- Care of the manual and how to consult it 3
- Introduction 3
- Revisions to the publication 3
- Symbols used in the manual 3
- Safety precautions 4
- Warnings and warranty conditions 4
- Information 5
- Intended use 5
- Warnings and warranty conditions 5
- Warranty conditions 5
- Exclusions 6
- Warnings and warranty conditions 6
- Spare parts 7
- Warnings and warranty conditions 7
- Warnings for the correct disposal of the product 7
- Installation 9
- Installation foreword 9
- Minimum distances 9
- Foreword 10
- Min 5 metri 10
- Smoke flue 10
- Technical characteristics 11
- Dimensioning 12
- Chimney 13
- Chimney components 13
- Maintenance 13
- External air inlet 14
- Connection to flue 15
- Examples of correct installation 17
- Dimensions and technical characteristics 18
- Forma wood 75 dx sx dimensions sx left version in figure 18
- Dimensions and technical characteristics 19
- Forma wood 95 dx sx dimensions sx left version in figure 19
- Technical dept all rights reserved reproduction is prohibited 19
- Dimensions and technical characteristics 20
- Forma wood t95 dimensions 20
- Dimensions and technical characteristics 21
- Forma wood t50 dimensions 21
- Technical dept all rights reserved reproduction is prohibited 21
- Dimensions and technical characteristics 22
- Technical characteristics 22
- Installation and assembly 23
- Preparation and unpacking 23
- Choice of operating mode 24
- Counterweights unlocking 24
- Forced convection comfort air vf 24
- Installation and assembly 24
- Natural convection comfort air vn 24
- Installation and assembly 25
- Positioning 25
- Height and level adjustment 26
- Installation and assembly 26
- Combustion air inlet 27
- External and internal air inlet 27
- Forced ventilation air inlet 27
- Installation and assembly 27
- Natural ventilation air inlet 27
- Cladding and counter hood assembly 28
- Flue connection 28
- Installation and assembly 28
- Fireplace insulation 29
- Hood ventilation outlets 29
- Installation and assembly 29
- Wooden beam insulation 29
- Do not expect heating efficiency immediately 30
- Operation 30
- Operation test 30
- Start up precautions 30
- Fuel wood 31
- Operation 31
- Stages for the first start up test 31
- First ignition 32
- Operation 32
- Fuel loading 33
- Operation 33
- Combustion control 34
- Operation 34
- Primary air 34
- Door opening switch 35
- Operation 35
- Quick response 35
- Secondary air 35
- Cleaning performed by the user 36
- Cleaning the glass 36
- Maintenance and cleaning 36
- Cleaning performed by a qualified technician 37
- Cleaning the ash 37
- Cleaning the chimney 37
- Cleaning the refractory parts alutec 37
- Maintenance and cleaning 37
Похожие устройства
- MCZ Forma T50 Сертификат
- CAS ER JR-15CB LT черные Инструкция по эксплуатации
- CAS ER JR-15CB черные Инструкция по эксплуатации
- MCZ HydroTherm 70 dx Инструкция по эксплуатации
- MCZ HydroTherm 70 dx Сертификат
- CAS ER JR-30CB LT черные Инструкция по эксплуатации
- MCZ HydroTherm E80 Инструкция по эксплуатации
- MCZ HydroTherm E80 Сертификат
- MCZ HydroTherm 70V Инструкция по эксплуатации
- MCZ HydroTherm 70V Сертификат
- CAS ER JR-15CBU черные Инструкция по эксплуатации
- MCZ HydroTherm 80 Инструкция по эксплуатации
- MCZ HydroTherm 80 Сертификат
- CAS ER JR-30CB черные Инструкция по эксплуатации
- MCZ HydroTherm 70 sx Инструкция по эксплуатации
- MCZ HydroTherm 70 sx Сертификат
- CAS ER JR-6CBU черные Инструкция по эксплуатации
- Cold Vine С12-TBF2 Инструкция по эксплуатации
- AR WY-808 Инструкция по эксплуатации
- CAS ER JR-6CB черные Инструкция по эксплуатации