Lincat GS7/RpFL [10/12] Spares list
![Lincat GS4nFL [10/12] Spares list](/views2/1337534/page10/bga.png)
IS212 ECN3592
10
Loosen the retaining nut at the rear of the burner.
Loosen the retaining nut at the injector end of the burner.
Remove the burner retainer bracket and the heat shield mounting screws.
Lift the burner clear of the assembly.
Refitting is the reverse of the above.
3.3 SPARES LIST
The following components are listed with the Lincat reference number followed by a brief description.
VA11 Multi function valve. *
TC34 Thermocouple.
BU87 Griddle burner.
JE35 GS7/N Burner injector – natural gas – stamp code: 160
JE141 GS7/P Burner injector – propane gas – stamp code: 75
JE68 GS4/N Burner injector – natural gas – stamp code: 210
JE67 GS4/P Burner injector – propane gas – stamp code: 100
PG10 Governor – Natural gas / Propane
KN184 Control knob
*
Note: When ordering a replacement valve the unit and gas type must be specified as the valves are
factory pre-set for the low rate settings.
Содержание
- Silverlink 600 gas griddles gs4 and gs7 1
- User installation and servicing instructions 1
- Installation and servicing instructions 2
- Gs4 units gs4 units 3
- Gs7 units 3
- Natural gas g20 supply pressure 20mbar 3
- Propane gas g31 supply pressure 30 50 mbar 3
- Technical data 3
- Contents 4
- Foreword 5 4
- Installation instructions 6 7 4
- Operating instructions 8 4
- Service information 12 4
- Servicing 9 10 4
- Troubleshooting 11 4
- Consequential loss 5
- Foreword 5
- Important please read this page carefully before using the equipment warning it is mandatory that all appliances are installed commissioned and serviced by a qualified and competent person as defined by the regulations in force in the country of installation failure to comply will invalidate the warranty 5
- Maintenance 5
- Gas supply connection 6
- Installation commissioning 6
- Installation instructions 6
- Installation position 6
- Ventilation 6
- Heat input 7
- Pressure setting 7
- Care of griddle plates 8
- Do not use sharp cornered instruments on a chromed griddle surface 8
- Lighting the appliance 8
- Operating instructions 8
- Preparation for use 8
- Shut down of appliance 8
- Warnin 8
- Component replacement 9
- General service 9
- Please see page 12 service for information on authorised service agents 9
- Servicing 9
- Spares list 10
- Troubleshooting 11
- 01522 875 520 12
- Authorised service agents 12
- Conditions of guarantee 12
- Contact information 12
- Guarantee statement 12
- Lincat service help desk 12
- Service information 12
Похожие устройства
- Lincat GS7/RpFL Каталог оборудования Lincat (англ.)
- Lincat HC3FL Инструкция по эксплуатации
- Lincat HC3FL Каталог оборудования Lincat (англ.)
- Lincat GS7/RnFL Инструкция по эксплуатации
- Lincat GS7/RnFL Каталог оборудования Lincat (англ.)
- Lincat GS7FL Инструкция по эксплуатации
- Lincat GS7FL Каталог оборудования Lincat (англ.)
- Lincat GS7nFL Инструкция по эксплуатации
- Lincat GS7nFL Каталог оборудования Lincat (англ.)
- Lincat HC4FL Инструкция по эксплуатации
- Lincat HC4FL Каталог оборудования Lincat (англ.)
- Lincat HC6FL Инструкция по эксплуатации
- Lincat HC6FL Каталог оборудования Lincat (англ.)
- Lincat HC7FL Инструкция по эксплуатации
- Lincat HC7FL Каталог оборудования Lincat (англ.)
- Bugatti VERA EASY Chrome Инструкция по эксплуатации
- Bugatti VERA EASY Black Инструкция по эксплуатации
- Airhot SV-30 Инструкция по эксплуатации
- Bugatti VERA EASY Cream Инструкция по эксплуатации
- Rock Kitchen WB-30A Инструкция по эксплуатации