Lincat GS7nFL — настройка давления и тепловая мощность газовых приборов [7/12]
![Lincat GS7/RnFL [7/12] Pressure setting](/views2/1337534/page7/bg7.png)
IS212 ECN3592
7
1.5 PRESSURE SETTING
Pressure setting can be carried out by the removal of the facia panel. This procedure is to expose the test
nipple.
With all burners lit and set to maximum, ensure that the supply pressure for Natural gas appliances is
20mbar and the burner pressure is adjusted to 16mbar. For Propane appliances ensure the supply pressure
is set to 37mbar and the burner pressure is set to 25mbar.
Pressure measurement is via the test nipple at the end of the manifold rail. Note: To obtain the above
burner pressures adjust the regulator as supplied with unit. When correct operating pressures are
obtained, re-assemble the unit.
1.6 HEAT INPUT
The total nominal gross heat input for the appliances with both burners in full operation are as follows: -
GS4/N Natural gas 5.4 kW
GS4/P Propane gas 5.5 kW
GS7/N Natural gas 7.5 kW
GS7/P Propane gas 8.0 kW
Содержание
- User installation and servicing instructions p.1
- Silverlink 600 gas griddles gs4 and gs7 p.1
- Installation and servicing instructions p.2
- Technical data p.3
- Propane gas g31 supply pressure 30 50 mbar p.3
- Natural gas g20 supply pressure 20mbar p.3
- Gs7 units p.3
- Gs4 units gs4 units p.3
- Troubleshooting 11 p.4
- Servicing 9 10 p.4
- Service information 12 p.4
- Operating instructions 8 p.4
- Installation instructions 6 7 p.4
- Foreword 5 p.4
- Contents p.4
- Important please read this page carefully before using the equipment warning it is mandatory that all appliances are installed commissioned and serviced by a qualified and competent person as defined by the regulations in force in the country of installation failure to comply will invalidate the warranty p.5
- Foreword p.5
- Consequential loss p.5
- Maintenance p.5
- Ventilation p.6
- Installation position p.6
- Installation instructions p.6
- Installation commissioning p.6
- Gas supply connection p.6
- Pressure setting p.7
- Heat input p.7
- Warnin p.8
- Shut down of appliance p.8
- Preparation for use p.8
- Operating instructions p.8
- Lighting the appliance p.8
- Do not use sharp cornered instruments on a chromed griddle surface p.8
- Care of griddle plates p.8
- Component replacement p.9
- Servicing p.9
- Please see page 12 service for information on authorised service agents p.9
- General service p.9
- Spares list p.10
- Troubleshooting p.11
- Service information p.12
- Lincat service help desk p.12
- Guarantee statement p.12
- Contact information p.12
- Conditions of guarantee p.12
- Authorised service agents p.12
- 01522 875 520 p.12
Похожие устройства
-
Lincat LGR2Каталог оборудования Lincat (англ.) -
Lincat LGR2Инструкция по эксплуатации -
Lincat GS7nFLКаталог оборудования Lincat (англ.) -
Lincat GS7FLКаталог оборудования Lincat (англ.) -
Lincat GS7FLИнструкция по эксплуатации -
Lincat GS7/RnFLКаталог оборудования Lincat (англ.) -
Lincat GS7/RnFLИнструкция по эксплуатации -
Lincat GS7/RpFLКаталог оборудования Lincat (англ.) -
Lincat GS7/RpFLИнструкция по эксплуатации -
Lincat GS7pFLКаталог оборудования Lincat (англ.) -
Lincat GS7pFLИнструкция по эксплуатации -
Lincat GS65FLКаталог оборудования Lincat (англ.)
Узнайте, как правильно настроить давление для газовых приборов и их тепловую мощность. Подробные инструкции по настройке и измерению давления.