Lainox RDRC83T [18/20] Professional catering

Lainox PCMC02T [18/20] Professional catering
18 18
NewChill
18
C20 C40 - C42C02
Professional Catering
Models N° of trays Spacing
Dimensions
mm
Cell dimensions
mm
Type
Core temperature
°C
Supply voltage
Volt
Total power
Watt *
Output per cycle **
Kg
RDR C20 T
20 x GN 1/1
890x1220x2180h 740x760x1880h chiller +90 +3 3N AC 400 50 Hz 5200 70
RDM C20 T
23 x GN 1/1
890x1220x2180h 740x760x1880h chill./free. +90 +3 · +90 -18 3N AC 400 50 Hz 7000 70 · 48
RCR C20 T 890x1220x2180h 740x760x1880h chiller +90 +3 3N AC 400 50 Hz 7100 105
RCM C20 T 890x1220x2180h 740x760x1880h chill./free. +90 +3 · +90 -18 3N AC 400 50 Hz 8100 105 · 70
DESIGNED TO CONTAIN: 1 KKS 201(20X1/1GN 267) TROLLEY OR 1 CT 2311 (23X1/1GN 270) TROLLEY
RDR C40 T
40 x GN 1/1
20 x GN 2/1
23 x GN 2/1
1500x1350x2230h 770x1050x1920h chiller +90 +3 3N AC 400 50 Hz 7800 150
RDM C40 T 1500x1350x2230h 770x1050x1920h chill./free. +90 +3 · +90 -18 3N AC 400 50 Hz 11500 150 · 100
RCR C40 T 1500x1350x2230h 770x1050x1920h chiller +90 +3 3N AC 400 50 Hz 11300 210
RCM C40 T 1500x1350x2230h 770x1050x1920h chill./free. +90 +3 · +90 -18 3N AC 400 50 Hz 14500 210 · 135
DESIGNED TO CONTAIN:1 KKS 202 (40X1/1GN-20X2/1GN 267) TROLLEY OR 1 X CT 2321 (23X2/1GN 270) TROLLEY OR 1 X CT 2311 (23X1/1GN 270) TROLLEY
RDR C42 T
40 x GN 1/1
20 x GN 2/1
23 x GN 2/1
1500x1480x2230h 770x1120x1920h chiller +90 +3 3N AC 400 50 Hz 7800 150
RDM C42 T 1500x1480x2230h 770x1120x1920h chill./free. +90 +3 · +90 -18 3N AC 400 50 Hz 11500 150 · 100
RCR C42 T 1500x1480x2230h 770x1120x1920h chiller +90 +3 3N AC 400 50 Hz 11300 210
RCM C42 T 1500x1480x2230h 770x1120x1920h chill./free. +90 +3 · +90 -18 3N AC 400 50 Hz 14500 210 · 135
THROUGH DOORS / DESIGNED TO CONTAIN: 1 KKS 202 (40X1/1GN-20X2/1GN 267) TROLLEY OR 1 X CT 2321 (23X2/1GN 270) TROLLEY OR 1 X CT 2311 (23X1/1GN 270)
RDR C82 T
2 x 20 x GN 2/1
2 x 40 x GN 1/1
2 x 23 x GN 2/1
1500x2480x2230h 770x2120x1920h chiller +90 +3 3N AC 400 50 Hz 14000 300
RDM C82 T 1500x2480x2230h 770x2120x1920h chill./free. +90 +3 · +90 -18 3N AC 400 50 Hz 16500 300 · 200
RCR C82 T 1500x2480x2230h 770x2120x1920h chiller +90 +3 3N AC 400 50 Hz 19200 420
RCM C82 T 1500x2480x2230h 770x2120x1920h chill./free. +90 +3 · +90 -18 3N AC 400 50 Hz 24000 420 · 270
THROUGH DOORS / DESIGNED TO CONTAIN: 2 KKS 202 (40X1/1GN-20X2/1GN 267) TROLLEY OR 2 X CT 2321 (23X2/1GN 270) TROLLEY OR 2 X CT 2311 (23X1/1GN 270) TROLLEY
RDR C83 T
3 x 20 x GN 2/1
3 x 40 x GN 1/1
3 x 23 x GN 2/1
1500x3480x2230h 770x3120x1920h chiller +90 +3 3N AC 400 50 Hz 20400 450
RDM C83 T 1500x3480x2230h 770x3120x1920h chill./free. +90 +3 · +90 -18 3N AC 400 50 Hz 30700 450 · 300
RCR C83 T 1500x3480x2230h 770x3120x1920h chiller +90 +3 3N AC 400 50 Hz 24600 630
RCM C83 T 1500x3480x2230h 770x3120x1920h chill./free. +90 +3 · +90 -18 3N AC 400 50 Hz 37200 630 · 405
THROUGH DOORS / DESIGNED TO CONTAIN: 3 KKS 202 (40X1/1GN-20X2/1GN 267) TROLLEY OR 3 X CT 2321 (23X2/1GN 270) TROLLEY OR 3 X CT 2311 (23X1/1GN 270) TROLLEY
Cell assembled with modular panels (excluded mod. C20). Complete with condenser unit. The heatable temperature probe is supplied as standard.
* Maximum electrical power in Watts: R 0°C/+55°C, M -10°C/+55°C. ** The output per cycle figures are indicative and also depend on the thickness of the product.
(Confectionery)

Содержание

Скачать