Detailed operation for buttons
HOLD (hold the current temperature)
• In the normal working mode, press HOLD once, MCU will record their measured
temperature data and show it on the LCD without changing. It will keep un-
changed any more, regardless of sensor measured temperature changed or not.
• Press HOLD again, the display will not reserve, after sensor measured the new
data, it will show the current data, and enter the normal working mode.
• When press HOLD button, the readings will show unchanged, and sensor won’t
measure the temperature (for economizing on electricity, because it is useless to
measure the temperature, the LCD won’t show it), unless press HOLD button
again, it will begin to measure and show the renewed temperature at once.
• When turn on HOLD, LCD will show HOLD symbol, after turn off, it will be without it.
• Only when the probe input, it do have this functions.
MAX-MIN MEMORY
(show max. and min. memory data after thermometer switch ON. During switch
ON lo-hi (HI/ALARM-LO/ALARM) temperature alert:
• Press MAX-MIN MEMORY button once, the upper line will show the max. and
min. memory data when power on, the left side is for Min data, the right one
is for Max. data.
• After pressing and hold the buttons for 5 seconds, it will return to the normal
working mode.( after turn on the HI and LO ALARM, the current display is the
temperature of alarm.)
• The memorized data will be clear automatically after power off (press ON/OFF
button), it will resume to measure the max and min data after restart the unit.
• While the temperature alarm is ON, press the button once can show the mem-
orized max and min data after power on.
• Press and hold the button for 3 seconds, it will clear the max and min data.
• While inserting or pull the probe, it will clear the max and min data.
07851Manual2012:07851Manual0212 07.02.2012 12:49 Page 12
Содержание
- Manual2012 07851manual0212 07 2 012 12 49 page 1 1
- Pro dt851 1
- Инстрóêция по применению 1
- С системой предупреждения о превышении максимальных и минимальных предельных значений 1
- Цифровой высоко температурный термометр 1
- Manual2012 07851manual0212 07 2 012 12 49 page 2 2
- Manual2012 07851manual0212 07 2 012 12 49 page 3 3
- Manual2012 07851manual0212 07 2 012 12 49 page 4 4
- Manual2012 07851manual0212 07 2 012 12 49 page 5 5
- Manual2012 07851manual0212 07 2 012 12 49 page 6 6
- Дополнительные характеристики 6
- Manual2012 07851manual0212 07 2 012 12 49 page 7 7
- Manual2012 07851manual0212 07 2 012 12 49 page 15 11
- Other specifications 11
- Manual2012 07851manual0212 07 2 012 12 49 page 14 12
- Manual2012 07851manual0212 07 2 012 12 49 page 13 13
- Manual2012 07851manual0212 07 2 012 12 49 page 12 14
- Manual2012 07851manual0212 07 2 012 12 49 page 11 15
- High temperature thermometer 16
- Manual2012 07851manual0212 07 2 012 12 49 page 10 16
- User manual 16
- With probe with high and low temperature 16
Похожие устройства
- RST RST08081 Инструкция по эксплуатации
- RST RST08083 Инструкция по эксплуатации
- RST RST08085 Инструкция по эксплуатации
- RST RST08087 Инструкция по эксплуатации
- RST RST08088 Инструкция по эксплуатации
- RST RST32508 Инструкция по эксплуатации
- RST RST32704 Инструкция по эксплуатации
- RST RST32703 Инструкция по эксплуатации
- RST RST32705 Инструкция по эксплуатации
- RST RST32707 Инструкция по эксплуатации
- RST RST32711 Инструкция по эксплуатации
- RST RST32712 Инструкция по эксплуатации
- SpezVision SVI-372V Инструкция по эксплуатации
- SpezVision SVI-372V Сертификат
- SpezVision SVI-372V Паспорт
- SpezVision SVI-172B Инструкция по эксплуатации
- SpezVision SVI-272V Инструкция по эксплуатации
- SpezVision SVI-272V Сертификат
- SpezVision SVI-272V Паспорт
- SpezVision SVI-372B Инструкция по эксплуатации