Nec V302W [59/119] Data part

Nec PA703W [59/119] Data part
©NEC Display Solutions, Ltd. 2014-2017 59
Response
When the command succeeds
23h 05h <ID1> <ID2> 10h <DATA01> - <DATA16> <CKS>
Data part
Item Description
DATA01 Adjusted value status
00h Display not possible
01h Adjustment not possible
02h Adjustment possible
FFh The specified gain does not exist.
DATA02 Upper limit of the adjustment range (low-order 8 bits)
DATA03 Upper limit of the adjustment range (high-order 8 bits)
DATA04 Lower limit of the adjustment range (low-order 8 bits)
DATA05 Lower limit of the adjustment range (high-order 8 bits)
DATA06 Default value (low-order 8 bits)
DATA07 Default value (high-order 8 bits)
DATA08 Current value (low-order 8 bits)
DATA09 Current value (high-order 8 bits)
DATA10 Wide adjustment width (low-order 8 bits)
DATA11 Wide adjustment width (high-order 8 bits)
DATA12 Narrow adjustment width (low-order 8 bits)
DATA13 Narrow adjustment width (high-order 8 bits)
DATA14 Whether the default value is valid or invalid
00h The default value is invalid.
01h The default value is valid.
DATA15
DATA16
Reserved for the system
When the command fails
A3h 05h <ID1> <ID2> 02h <ERR1> <ERR2> <CKS>

Содержание