Fubag BS 1100 [7/30] Operator s manual

Содержание

rubag Operator s manual www fubag ru Fuelling the Power Generator These requirements must be fulfilled Appliance is switched off Appliance is cool Adequate air supply and ventilation Avoid fuel leakages Appliance is switched off Appliance is cooled Avoid naked flames and sparks Do not fill tank to maximum Use filling device funnel Only fill with regular gasoline petrol 91 93 1 Push the fuel valve to the OFF position 2 Unscrew the tank cap 3 Insert filling device funnel into the tank 4 Fill with fuel 5 Remove the filling device 6 Replace the tank cap Filling the Power Generator with Motor Oil The power generator is as a rule delivered without oil It is not possible to start the appliance if the oil level is too low because the motor is fitted with an oil monitor These requirements must be fulfilled Appliance is switched off Appliance is cool WARNING Leaking motor oil and fuel contaminates the soil and ground water Do not fill crankcase to maximum check the volume with oil dipstick Use filling device funnel WARNING Incorrect motor oil will damage motor irreparably Please check the ambient temperature and fill with the following listed oil type 0 SAE 10 or 10W30 10W40 0 25 SAE20or10W30 10W40 25 35 SAE 30 or 10W30 10W40 35 t o SAE 40 or 10W30 10W40 1 Unscrew oil dipstick 2 Insert filling device funnel into the opening not supplied 3 Fill motor oil up to the edge ofthe oil filler neck 4 Remove filling device 5 Replace oil dipstick 6 If oil level is too low repeat filling procedure 7 Tighten oil dipstick 6

Скачать