Fubag AUTO MASTER KIT+10 [11/21] Page10
Содержание
- Cover 1 1
- Operator s manual 1
- Инструкция по эксплуатации 1
- Operator s manual 2
- Page01 2
- Page02 3
- Page03 4
- Page04 5
- Operator s manual 6
- Page05 6
- Operator s manual 7
- Page06 7
- Safety operation 7
- Caution 8
- Not to do 8
- Operator s manual 8
- Page07 8
- Auto cottage 9
- Caution 9
- Operator s manual 9
- Page08 9
- Technical specifications 9
- Page09 10
- Operator s manual 11
- Page10 11
- Tool operation and c onnection 11
- Maintenance 12
- Operator s manual 12
- Page11 12
- The service life of the machine depends on maintenance quality before carrying outany operation always pull out the plug and drain the receiver completely fig 10 11 tighten the tie bolts of the head at start up and after the first hour of work torque 10 nm 1 2 kgm after loosening any safety screws fig 12a clean the intake filter according to the type of working environment and at least every 100 hours fig 12b 12c if necessary replace the filter element clogging of the filter reduces compressor performance and an inefficient filter causes increased wear in lubricated models replace the oil after the first 100 hours of operation and every 300 hours subsequently fig 13a 13b 13c remember to check the oil level at regular intervals periodically or after working with the compressor for more than an hour drain the condensate that forms inside the receiver fig 11 and filter fig 15c this protects the receiver from corrosion and does not restrict its capacity regularly clean and dry the filter f 12
- Operator s manual 13
- Page12 13
- Troubleshooting 13
- Warranty 13
- Page13 14
- Правила безопасности 14
- Шрад 14
- Page14 15
- Важно 15
- Запрещается 15
- Инструкция по эксплуатации 15
- Шрад 15
- Auto cottage 16
- Page15 16
- Важно 16
- Включайте подачу сжатого воздуха только после подсоединения инструмента 16
- Инструкция по эксплуатации 16
- Технические характеристики 16
- Шрад 16
- Page16 17
- Инструкция по эксплуатации 17
- Комплектация 17
- Лито 17
- Пуск и эксплуатация 17
- Шрад 17
- Page17 18
- Инструкция по эксплуатации 18
- Подключение и эксплуатация пневмоинструмента 18
- Page18 19
- Инструкция по эксплуатации 19
- Техническое обслуживание 19
- Page19 20
- Гарантийные обязательства 20
- Гиьад 20
- Инструкция по эксплуатации 20
- Неисправности и способы их устранения 20
- Cover 2 21
Похожие устройства
- Fubag DCF-1300/500 CT11 Инструкция по эксплуатации
- Fubag DCF-1300/270 CT11 Инструкция по эксплуатации
- Fubag DCF-1700/500 СТ15 Инструкция по эксплуатации
- Fubag VDС 400/50 CM3 Инструкция по эксплуатации
- Fubag VDС 400/100 CM3 Инструкция по эксплуатации
- Firman RD9910E Инструкция по эксплуатации
- Firman RD3910 Инструкция по эксплуатации
- Firman RD9910Е+ATS Инструкция по эксплуатации
- Firman RD9910TE Инструкция по эксплуатации
- Firman SDG8500TCLE Инструкция по эксплуатации
- Firman SDG5500CLE Инструкция по эксплуатации
- Firman SDG8500CLE Инструкция по эксплуатации
- Stihl KM 131 R Инструкция по эксплуатации
- Телеметрика Т100 Инструкция по эксплуатации
- Boneco W200 Инструкция по эксплуатации
- Ballu UHB-255 E Инструкция по эксплуатации
- Stabila LD 250 BT Инструкция по эксплуатации
- Ballu UHB-240 blue/голубой Disney Инструкция по эксплуатации
- Hitachi C7MFA Инструкция по эксплуатации
- Hitachi SB10V2 Инструкция по эксплуатации
rubaq Operator s manual www fubag ru The absence of pressure in the head facilitates subsequent restart When air is used the compressor restarts automatically when the lower calibration value is reached approx 2 bar between upper and lower The pressure inside the reservoir can be checked on the gauge provided fig 8 The compressor continues to operate automatically with this work cycle until the position of the switch of the pressure switchis modified To use the compressor again wait at least 10 seconds after this has been switched off before restarting Air pressure can be regulated in order to optimize use of air powered tools operating on the knob with the valve open pulling it up and turning it in a clockwise direction to increase pressure and counterclockwise to reduce this fig 9a 9b 9c 9d Once you have set the value required push the knob down to lock it Please check that the air consumption and the maximum working pressure of the pneumatic tool to be used are compatible with the pressure set on the pressure regulator and with the amount of air supplied by the compressor When you have finished working stop the machine pull out the plug and empty the reservoir fig 10 11 5 Tool operation and c onnection The tool should be connected only to an air supply system including components specified in fig A except for spray guns which should be connected to a lubricator Provide for clean and dry compressed air with a suitable oil mixture Use the correct air treatment unit filter pressure regulator and lubricator The lubricator should apply 3 to 6 oil drops per minute Make sure spray guns are supplied with clean dry and filtered compressed air Hose maximum length between lubricator and tool should not exceed 10 meters Quick disconnect coupling fig 15A and the hose airflow should have sufficient capacity We recommend an air hose with an inner diameter of 10 mm Exclusively use genuine hoses accessories and tools In order to guarantee a good operation of the tool the compressed air maximus pressure should not exceed 6 bar unless otherwise specified Greater pressure may result in damages or toll excessive wear and therefore are not recommended Low working pressure may cause tool power decreasing or discontinuance To select the pressure to be used for each tool refer to the specific user s manual or to the instruction on the packaging Pneumatic hammers are not suitable for the demolition of reinforced concrete Before connecting accessories make sure the compressor is shut down Before operating the equipment put some oil drops in the air inlet opening of the pneumatic tool see fig 15D Assemble any accessory and connection on the tool Connect air hose to the tool 10