Telwin SUPERIOR TIG 322 AC/DC HF/LIFT 400V+ TIG ACC (816130) Инструкция по эксплуатации онлайн [5/156] 331519

Telwin SUPERIOR TIG 322 AC/DC HF/LIFT 400V+ TIG ACC (816130) Инструкция по эксплуатации онлайн [5/156] 331519
- 5 -
INVERTERWELDINGMACHINESFORTIGANDMMAWELDINGDESIGNEDFOR
INDUSTRIALANDPROFESSIONALUSE.
Note:Inthefollowingtexttheterm“weldingmachine”willbeused.
1.GENERALSAFETYCONSIDERATIONSFORARCWELDING
The operator should be properly trained to use the welding machine safely
andshouldbeinformedabouttherisksrelatedtoarcweldingprocedures,the
associatedprotectionmeasuresandemergencyprocedures.
(Pleaserefertotheapplicablestandard“EN60974-9:Arcweldingequipment.
Part9:InstallationandUse).
- Avoiddirectcontactwiththeweldingcircuit:theno-loadvoltagesuppliedby
theweldingmachinecanbedangerousundercertaincircumstances.
- When the welding cables are being connected or checks and repairs are
carriedouttheweldingmachineshouldbeswitchedoffanddisconnected
fromthepowersupplyoutlet.
- Switch off the welding machine and disconnect it from the power supply
outletbeforereplacingconsumabletorchparts.
- Maketheelectricalconnectionsandinstallationaccordingtothesafetyrules
andlegislationinforce.
- Theweldingmachineshouldbeconnectedonlyandexclusivelytoapower
sourcewiththeneutralleadconnectedtoearth.
- Make sure that the power supply plug is correctly connected to the earth
protectionoutlet.
- Donotusetheweldingmachineindamporwetplacesanddonotweldinthe
rain.
- Donotusecableswithworninsulationorlooseconnections.
- Donotweldoncontainersorpipingthatcontainsorhascontainedammable
liquidorgaseousproducts.
- Donotoperateonmaterialscleanedwithchlorinatedsolventsornearsuch
substances.
- Donotweldoncontainersunderpressure.
- Removeallammablematerials(e.g.wood,paper,ragsetc.)fromtheworking
area.
- Provideadequateventilationorfacilitiesfortheremovalofweldingfumesnear
thearc;asystematicapproachisneededinevaluatingtheexposurelimitsfor
the welding fumes, which will depend on their composition, concentration
andthelengthofexposureitself.
- Keep the gas bottle (if used) away from heat sources, including direct
sunlight.
- Useelectricinsulationthatissuitableforthetorch,theworkpieceandany
metalpartsthatmaybeplacedonthegroundandnearby(accessible).
Thiscannormallybedonebywearinggloves,footwear,headprotectionand
clothingthataresuitableforthepurposeandbyusinginsulatingboardsor
mats.
- Alwaysprotectyoureyeswiththerelativelters,whichmustcomplywithUNI
EN169orUNIEN379,mountedonmasksorusehelmetsthatcomplywithUNI
EN175.
Use the relative re-resistant clothing (compliant with UNI EN 11611) and
weldinggloves(compliantwithUNIEN12477)withoutexposingtheskinto
the ultraviolet and infrared rays produced by the arc; the protection must
extend to other people who are near the arc by way of screens or non-
reectivesheets.
- Noise:Ifthedailypersonalnoiseexposure(LEPd)isequaltoorhigherthan85
dB(A)becauseofparticularlyintensiveweldingoperations,suitablepersonal
protectivemeansmustbeused(Tab.1).
- The ow of the welding current generates electromagnetic elds (EMF)
aroundtheweldingcircuit.
Electromagneticeldscaninterferewithcertainmedicalequipment(e.g.Pace-
makers,respiratoryequipment,metallicprosthesesetc.).
Adequateprotectivemeasuresmustbeadoptedforpersonswiththesetypesof
medicalapparatus.Forexample,theymustbeforbiddenaccesstotheareain
whichweldingmachinesareinoperation.
Thiswelding machineconforms totechnicalproductstandardsfor exclusive
useinanindustrialenvironmentforprofessionalpurposes.Itdoesnotassure
compliancewiththebasiclimitsrelativetohumanexposuretoelectromagnetic
eldsinthedomesticenvironment.
Theoperatormustadoptthefollowingproceduresinordertoreduceexposure
toelectromagneticelds:
- Fastenthetwoweldingcablesasclosetogetheraspossible.
- Keepheadandtrunkasfarawayaspossiblefromtheweldingcircuit.
- Neverwindweldingcablesaroundthebody.
- Avoidweldingwiththebodywithintheweldingcircuit.Keepbothcableson
thesamesideofthebody.
- Connecttheweldingcurrentreturncabletothepiecebeingwelded,asclose
aspossibletotheweldingjoint.
- Donotweldwhilecloseto,sittingonorleaningagainsttheweldingmachine
(keepatleast50cmawayfromit).
- Do not leave objects in ferromagnetic material in proximityof the welding
circuit.
- Minimumdistanced:20cm(Fig.O).
-ClassAequipment:
Thiswelding machineconforms totechnicalproductstandardsfor exclusive
use in an industrial environment and for professional purposes. It does not
assure compliance with electromagnetic compatibility in domestic dwellings
and in premises directly connected to a low-voltage power supply system
feedingbuildingsfordomesticuse.
EXTRA PRECAUTIONS
- WELDINGOPERATIONS:
- Inenvironmentswithincreasedriskofelectricshock.
-Inconnedspaces.
-Inthepresenceofammableorexplosivematerials.
MUSTBEevaluatedinadvancebyan“Expertsupervisor”andmustalwaysbe
carriedoutinthepresenceofotherpeopletrainedtointerveneinemergencies.
Allprotectivetechnical measures MUST be taken asprovidedin7.10;A.8;
A.10oftheapplicablestandardEN60974-9:Arcweldingequipment.Part9:
InstallationandUse”.
-The operatorMUST NOT BE ALLOWED to weldin raised positions unless
safetyplatformsareused.
-VOLTAGE BETWEEN ELECTRODE HOLDERS OR TORCHES: working with
more than one welding machine on a single piece or on pieces that are
connected electrically may generate a dangerous accumulation of no-load
voltagebetweentwodifferentelectrodeholdersortorches,thevalueofwhich
mayreachdoubletheallowedlimit.
An expert coordinator must be designated to measuring the apparatus
to determine if any risks subsist andsuitableprotectionmeasures can be
adopted,asforeseenbysection7.9oftheapplicablestandard“EN60974-9:
Arcweldingequipment.Part9:InstallationandUse”.
RESIDUAL RISKS
-IMPROPER USE: it is hazardous to usethe weldingmachine forany work
otherthanthatforwhichitwasdesigned(e.g.de-icingmainswaterpipes).
2.INTRODUCTIONANDGENERALDESCRIPTION
2.1INTRODUCTION
This welding machine is a power source for arc welding, made specically for TIG
(DC) (AC/DC) welding with HF or LIFT strike and MMA welding with coated electrodes
(rutile, acid, basic).
The particular features of this welding machine (INVERTER), such as high-speed and
precise adjustment, result in excellent quality welds.
The inverter system of regulation at the power supply input (primary) also leads to a
drastic decrease in the volume of both the transformer and the levelling reactance so
that it is possible to build a considerably smaller, lighter welding machine, highlighting
ENGLISH
INDEX
1.GENERALSAFETYCONSIDERATIONSFORARCWELDING............................................... 5
2.INTRODUCTIONANDGENERALDESCRIPTION.................................................................... 5
2.1 INTRODUCTION .................................................................................................................. 5
2.2 OPTIONAL ACCESSORIES ................................................................................................. 6
3.TECHNICALDATA...................................................................................................................... 6
3.1 DATA PLATE (FIG. A) ........................................................................................................... 6
3.2 OTHER TECHNICAL DATA .................................................................................................. 6
4.DESCRIPTIONOFTHEWELDINGMACHINE......................................................................... 6
4.1 BLOCK DIAGRAM ................................................................................................................ 6
4.2 CONTROL, ADJUSTMENT AND CONNECTION DEVICES ................................................ 6
4.2.1 BACK PANEL (FIG. C) ............................................................................................... 6
4.2.2 Front panel FIG. D1 .................................................................................................... 6
4.2.3 Front panel FIG. D2 .................................................................................................... 7
4.3 STORING AND RECALLING OF PERSONALISED PROGRAMS ....................................... 8
4.4 G.R.A. water cooling unit ENABLING and DISABLING instructions (where applicable) ...... 8
5.INSTALLATION........................................................................................................................... 8
5.1 PREPARATION..................................................................................................................... 8
5.1.1 Assembling the return cable-clamp (FIG. E) ............................................................... 8
5.1.2 Assembling the welding cable-electrode holder clamp (FIG. E) ................................. 8
5.2 POSITION OF THE WELDING MACHINE ........................................................................... 8
5.3 CONNECTION TO THE MAIN POWER SUPPLY ................................................................ 8
5.3.1 Plug and outlet ............................................................................................................ 8
5.4 CONNECTION OF THE WELDING CABLES ...................................................................... 8
5.4.1 TIG welding................................................................................................................. 8
5.4.2 MMA WELDING .......................................................................................................... 8
6.WELDING:DESCRIPTIONOFTHEPROCEDURE................................................................... 8
6.1 TIG WELDING ...................................................................................................................... 8
6.1.1 HF and LIFT strike ...................................................................................................... 8
6.1.2 TIG DC welding .......................................................................................................... 9
6.1.3 TIG AC welding .......................................................................................................... 9
6.1.4 Procedure ................................................................................................................... 9
6.2 MMA WELDING .................................................................................................................... 9
6.2.1 Procedure ................................................................................................................... 9
7.MAINTENANCE.......................................................................................................................... 9
7.1 ROUTINE MAINTENANCE .................................................................................................. 9
7.1.1 Torch ........................................................................................................................... 9
7.2 EXTRAORDINARY MAINTENANCE .................................................................................... 9
8.TROUBLESHOOTING................................................................................................................ 9
page page

Содержание

Похожие устройства