Ada ProLevel 80 [6/26] Pro level 60 80 100

Ada ProLevel 80 [6/26] Pro level 60 80 100
6
ProLevel 60/80/100
Note:
1) The digital level has been pre-calibrated at the factory.
2) The level should only be recalibrated if level has been dropped.
3) “ERRO” shows when either the forward tilt angle or backward tilt angle is not less 30°.
CALIBRATING
1. Place the digital level on a flat and smooth surface, press A button and B button at the same time, the calibration mode is activated
and “-1-” will be displayed. Press A button again, “-1-” will flash briefly. Do not move until -2- is displayed.
2. Rotate the level 180° in the same location and press A button, -2- will flash briefly. Do not move until the unit has completed the
calibration and reset the display to the current level.