Airwell Westherm 70 [11/16] 55 fan speed
![Airwell Westherm 70 [11/16] 55 fan speed](/views2/1408117/page11/bgb.png)
Page 10
6 - Installation (cont'd)
6.4 - Supply Air Throw (m)
900 1400 900 1400 900 1400 900 1400 900 1400 700 900 900 1400
L
8.0 12.010.014.012.016.014.018.016.020.016.020.014.018.0
H
3.0 3.0 4.0 5.0 4.0 5.0 4.0 5.0 4.0 5.0 4.0 5.0 4.0 5.0
L
8.0 12.010.014.012.016.014.018.016.020.016.020.014.018.0
H
3.0 3.0 4.0 5.0 4.0 5.0 4.0 5.0 4.0 5.0 4.0 5.0 4.0 5.0
D
7.0 10.0 9.0 12.0 11.0 14.0 12.0 16.0 14.0 18.0 14.0 18.0 12.0 16.0
G *
4.0 4.5 4.5 5.0 4.5 5.5 5.0 6.0 5.5 6.5 5.5 6.5 5.0 6.0
S
- - - - - -
L
- - 6.0 8.0 7.0 9.0 7.5 9.0 - - - -
G
4.0 4.5 4.5 5.0 4.5 5.5 5.0 6.0 5.5 6.5 - - - -
D
7.0 10.0 9.0 12.0 11.0 14.0 12.0 16.0 14.0 18.0 - - - -
V
3.0 4.0 3.5 4.5 3.5 5.0 4.0 5.0 3.0 4.0 - - - -
X
3.0 4.0 4.0 5.0 4.5 5.5 5.0 6.0 5.5 6.5 - - - -
2.5 to 4.0
6.5 to 8.5
2.5 to 4.0 2.5 to 4.0
50 55
Fan s
p
eed
VM
3
5
4
5
VR
2.5 to 4.0
7
0
11
0
VN
HN
HO
HP
6
5
Size
s
* Air throw of diffuser HN can be increased by changing the shutter position.
Vertical arrangement Horizontal arrangement
Diffuser VR (air curtain)
Diffuser HO
Diffuser VM, VN Diffuser HP, HN
V
X
L
H
S
L
G
D
The air throw of a propeller fan unit heater is the distance between
the unit and the points where the air velocity is no longer felt by the
human body (approx. 0.2 m/sec.).
The air throw allows the units to be installed in the room.
The table below gives the air throw of a unit in relation to model and
Temp.
difference
Factor
1.28 1.00 0.90 0.70 0.60
40 °C10 °C 15 °C 20 °C 30 °C
Correction factor
supply diffuser, for a supply air temperature difference of 15 °C.
For other temperature differences, use the correction factor.
Содержание
- Westherm 35 110 1
- Description p 4 2
- Dimensional data and weight of options p 7 2
- Dimensional data and weight of standard units p 5 2
- Electrical connections p 14 2
- English 2
- Installation p 9 2
- Introduction p 3 2
- Maintenance p 15 2
- Preliminary checks before start up p 15 2
- Safety precautions p 3 2
- Table of contents 2
- Water connections p 12 2
- Caution 3
- Introduction 3
- Safety precautions 3
- The manufacturer warranty will not be applied if all installation instructions stated in this manual have not been followed 3
- Warning 3
- Description 4
- Electrical data 4
- English 4
- Inspection and storage 4
- Operating limits 4
- Standard motor data 4
- Unit in operation with hot water circulation 4
- Diffuser vm 5
- Diffuser vn 5
- Diffuser vr 5
- Dimensional data and weight of standard units 5
- Vertical arrangement 5
- Diffuser hn 6
- Diffuser ho 6
- Diffuser hp 6
- Dimensional data and weight of standard units cont d 6
- English 6
- Horizontal arrangement 6
- Arrangement 1 val arrangement 2 vaf arrangement 3 vak 7
- Arrangement 4 vajf 7
- Arrangement 5 vagk 7
- Arrangement 6 vagjf 7
- Component description 7
- Dimensional data and weight of options 7
- Dimensions 7
- Standard arrangements 7
- Arrangement 10 vabdf 8
- Arrangement 11 habgz 8
- Arrangement 12 habcgz 8
- Arrangement 7 vagz 8
- Arrangement 8 vabgz arrangement 9 vabf 8
- Dimensional data and weight of options cont d 8
- English 8
- Position of damper control shaft 8
- Standard arrangements 8
- Installation 9
- Unit handling 6 installation location 9
- Warning 9
- English 10
- Installation cont d 10
- Installation instructions 10
- Warning 10
- 55 fan speed 11
- C 10 c 15 c 20 c 30 c 11
- Correction factor 11
- Factor 1 8 1 0 0 0 0 0 0 0 11
- For other temperature differences use the correction factor 11
- Installation cont d 11
- Supply air throw m 11
- Supply diffuser for a supply air temperature difference of 15 c 11
- Temp difference 11
- The air throw allows the units to be installed in the room 11
- The air throw of a propeller fan unit heater is the distance between the unit and the points where the air velocity is no longer felt by the human body approx 0 m sec 11
- The table below gives the air throw of a unit in relation to model and 11
- Vertical arrangement horizontal arrangement 11
- English 12
- Warning 12
- Water coil connections 12
- Water connections 12
- Water volume in the coils 12
- Water connections cont d 13
- Water pressure drop 13
- Electrical connections 14
- English 14
- Standard wiring diagram 14
- To perform electrical wiring of fan motor please refer to wiring diagram supplied in the motor terminal box 14
- Unit connection 14
- Warning 14
- Air filter optional 15
- Caution 15
- Electrical connections 15
- Fan motor assembly 15
- Maintenance 15
- Page 14 15
- Preliminary checks before start up 15
- Vaf arrangement 15
- Val arrangement 15
- Water piping system 15
- Ace pons industrie 42 cours jean jaurès 17800 pons france 16
Похожие устройства
- Ammari AM-A-025-80 Инструкция по эксплуатации
- Airwell Westherm 70 Технические характеристики
- Airwell Westherm 110 Инструкция по эксплуатации
- Airwell Westherm 110 Технические характеристики
- Ammari AM-A-38-80 Инструкция по эксплуатации
- Airwell VH 03 Инструкция по эксплуатации
- Airwell VH 05 Инструкция по эксплуатации
- Airwell VH 07 Инструкция по эксплуатации
- Airwell VH 10 Инструкция по эксплуатации
- Airwell VH 15 Инструкция по эксплуатации
- Airwell VH 18 Инструкция по эксплуатации
- Airwell VH 21 Инструкция по эксплуатации
- Airwell VH 24 Инструкция по эксплуатации
- Airwell VH 27 Инструкция по эксплуатации
- Airwell VH2N 03 Инструкция по эксплуатации
- Airwell VH2N 03 Технические характеристики
- Airwell VH2N 05 Инструкция по эксплуатации
- Airwell VH2N 05 Технические характеристики
- Airwell VH2N 07 Инструкция по эксплуатации
- Airwell VH2N 07 Технические характеристики