Airwell CDN 505 [5/36] Power supply must be switched off before starting to work in the electric control
![Airwell CDN 505 [5/36] Power supply must be switched off before starting to work in the electric control](/views2/1408255/page5/bg5.png)
Содержание
- Cdn 205 r 905 1
- Aaaintenance 16 4
- Contents 4
- Cooling specifications 4
- English 4
- General 4 4
- General recommendations 3 4
- Operating limits application adjustement factor 7 selection procedure 8 unit installation 4
- Refrigerant circuit diagram acoustic capacity spectrums 7 4
- Regulation 3 electrical connections 14 4
- Technical specifications 4
- Wiring diagram 1 4
- General recommendations 5
- Power supply must be switched off before starting to work in the electric control 5
- Safety directions 5
- The manufacturer declines any responsibility and the warrantly becomes void if these instructions are not respected 5
- Warning 5
- Air cooled condensers 6
- Compressor 6
- Condenser fan and motor 6
- Electrical panel 6
- English 6
- Evaporator 6
- General 6
- English 7
- Single circuit 7
- Technical specifications 7
- Cooling specifications 8
- Dual circuit 8
- English 8
- Information only 8
- Single circuit 8
- 0 943 1 038 9
- 0 958 1 029 9
- 0 973 1 02 9
- 0 987 1 01 9
- Acoustic capacity level 9
- Acoustic capacity spectrums 9
- Altitude m cooling capacity power input 9
- Application adjustement factor 9
- Dual circuit 9
- English 9
- Operating limits 9
- Refrigerant circuit diagram 9
- See appendix 9
- Single circuit 9
- 1 midle point between dew point and bulb point 10
- 2 satured temperatur dew point at compressor suction pressure 10
- 3 at lower ambient air temperatures capacities and performances remain constant by means of condensing pressure control 10
- English 10
- For conditions differents from those indicated in performance tables interpolations is allowed however extrapolation is not permitted 10
- Selection procedure 10
- Table valid for 6k sub cooling and a 8k superheat 10
- The power input is the total input compressors fans 10
- A 500 800 11
- English 11
- Location 11
- Minimum free clearance mm 11
- Model 205 305 405m 405 505 605 755 905 11
- Refrigerant lines 11
- Unit installation 11
- English 12
- English 13
- See appendix 13
- Wiring diagram 13
- Capacitor value 14
- Cdn 205 305 12 14
- Cdn 405 505 605 10 14
- English 14
- Adjustment of pressure switches 15
- All warranties are void if the instructions 15
- Below are not followed 15
- Colour code 15
- Dual circuit 15
- English 15
- Range and setting of compressor thermal relays current rating of unit contactors class ac3 15
- Regulation 15
- Single circuit 15
- Electrical connections 16
- English 16
- Following conditions 16
- Green led 0 16
- Green led 1 16
- N 400v 16
- N 400v 50hz 16
- This product is equipped with a phase sequence controller the led s indicate the 16
- This switch can be padlocked 16
- Very important 16
- Yellow led 0 16
- Yellow led 1 16
- English 17
- Frequency drive 17
- Before starting any work on the unit you must ensure that the power supply 18
- Electrical circuit 18
- Electrocution 18
- General installation 18
- Is cut off and that there is no possibility of it being accidentally switched back on failure to comply with this measure can lead to injury or death by 18
- It is recommended that the local switch be padlocked 18
- Maintenance 18
- Refrigerant circuit 18
- Abmessungen ill 20
- Allegato 20
- Anlage 20
- Annexe 20
- Annexe annexe anlage allegato anexo 20
- Appendix 20
- Dimensiones 20
- Dimensions iii 20
- Dimensions ill 20
- Esquema del circuito frigorífico vili 20
- Esquema electrico x 20
- Kältekreislaufdiagramm viii 20
- Refrigerant circuit diagram viii 20
- Schema del circuito refrigerante viii 20
- Schema du circuit frigorifique viii 20
- Schema eletrico x 20
- Schemas electriques x 20
- Stromlaufplans x 20
- Wiring diagram x 20
- Annexe annexe anlage allegato anexo 22
- Annexe annexe anlage allegato anexo 23
- Annexe annexe anlage allegato anexo 24
- Annexe annexe anlage allegato anexo 25
- Annexe i annexe i anlage i allegato i anexo 26
- Esquema del circuito frigorìfico 26
- Kältekreislaufdiagramm 26
- Refrigerant circuit diagram 26
- Schema del circuito refrigerante 26
- Schema du circuit frigorifique 26
- Annexe annexe anlage allegato anexo 27
- Version bac 27
- Version baz 27
- Annexe annexe anlage allegato anexo 28
- Esquema electrico 28
- Schema eletrico 28
- Schemas electriques 28
- Stromlaufplans 28
- Wiring diagram 28
- Annexe i annexe anlage allegato anexo 29
- C d n m dnocompressor 29
- L it2 tl i 29
- Power wiring 29
- Se 3214 b 399774 29
- Wiring diagram legend n722 29
- O o in 31
- Annexe annexe anlage allegato anexo 32
- Con 755 905 32
- Se 3494 399908 32
- Wiring diagram legend n722 32
- X se 3493 32
- Annexe annexe anlage allegato anexo 33
- Il è 1 33
- Li l2 l3 33
- N400v 50hz 1 33
- N415v 50hz i 33
- Power wiring puissance 33
- Se 3493 399907 33
- Split duci fed units 33
- Wiring by installer 33
- Declaración ce de conformidad 35
- Dichiarazione ce di conformità 35
- Déclaration ce de conformité 35
- Ec compliance declaration 35
- Eg konformitätserklärung 35
- Ace industrie 36
- Industrie 36
- Route de verneuil 27570 lillières sur avre france 33 0 2 32 60 61 00 s 33 0 2 32 32 55 13 36
- Your distri butor votre agent commercial 36
Похожие устройства
- Airwell CDN 505 Техническое описание
- Airwell CDN 505 Инструкция по монтажу
- Airwell CDN 605 Инструкция по эксплуатации
- Airwell CDN 605 Техническое описание
- Airwell CDN 605 Инструкция по монтажу
- Airwell CDN 755 Инструкция по эксплуатации
- Airwell CDN 755 Техническое описание
- Airwell CDN 755 Инструкция по монтажу
- Airwell CDN 905 Инструкция по эксплуатации
- Airwell CDN 905 Техническое описание
- Airwell CDN 905 Инструкция по монтажу
- Airwell VLC 524 Инструкция по эксплуатации
- Airwell VLC 604 Инструкция по эксплуатации
- Airwell VLC 704 Инструкция по эксплуатации
- Airwell VLC 804 Инструкция по эксплуатации
- Airwell VLC 904 Инструкция по эксплуатации
- Airwell VLC 1004 Инструкция по эксплуатации
- Airwell VLC 1104 Инструкция по эксплуатации
- Airwell VLC 1204 Инструкция по эксплуатации
- Airwell RT4D 20 Инструкция по эксплуатации
POWER SUPPLY MUST BE SWITCHED OFF BEFORE STARTING TO WORK IN THE ELECTRIC CONTROL BOX GENERAL RECOMMENDATIONS Please read the following safety precautions very carefully before installing the unit SAFETY DIRECTIONS Follow the safety rules in forces when you are working on your appliance The installation commissioning and maintenance of these units should be performed by qualified personnel having a good knowledge of standards and local regulations as well as experience of this type of equipment The unit should be handled using lifting and handling equipment appropriate to the unit s size and weight Any wiring produced on site must comply with the corresponding national electrical regulations Make sure that the power supply and its frequency are adapted to the required electric current of operation taking into account specific conditions of the location and the current required for any other appliance connected with the same circuit The unit must be EARTHED to avoid any risks caused by insulation defects It is forbidden to start any work on the electrical components if water or high humidity is present on the installation site WARNING Cutoff power supply before starting to work on the appliance When making the hydraulic connections ensure that no impurities are introduced into the pipe work The manufacturer declines any responsibility and the warrantly becomes void if these instructions are not respected If you meet a problem please call the Technical Department of your area If possible assemble the mandatory or optional accessories before placing the appliance on its final location see instructions provided with each accessory In order to become fully familiar with the appliance we suggest to read also our Technical Instructions The information contained in these Instructions are subject to modification without advance notice 3