General specifications (continued)
Integrated hydraulic module
An integrated hydraulic module is available for all Aqu@Logic air
cooled water chillers, offering savings in installation times and
reducing installation costs. Each hydraulic module comprises the
following components :
On models 20 to 35 : Automatic air bleed valve, differential
pressostat, drain cock, expansion tank, safety valve, pressure
gauge, hydraulic pump and water filter (supplied as a kit - not
fitted).
On models 40 to 130 : Automatic air bleed valve, water flow
adjustment valve, water flow switch, drain cock, expansion tank,
safety valve, pressure gauge, hydraulic pump and fitted water
filter.
As standard, all pumps produce available pressure higher than
100 kPa. A pump producing available pressure higher than
150 kPa can be supplied on request.
Other standard equipment :
Anti-vibration pads kit : The 20 to 130 models are supplied with
rubber anti-vibration pads as standard, to be fitted on site by the
installer.
Water flow switch or differential pressostat : For Aqu@Logic
units without an integrated hydraulic module, a factory-fitted
differential pressostat (for models 20 to 35) and a field-installed
paddle type water flow switch (for models 40 to 130) are supplied
as standard.
Water filter : Supplied loose.
Coil protection grilles : Aqu@Logic units are supplied with
heat exchanger coil protection grilles as standard.
Accessories and options :
Anti-vibration pads kit : For models 40 to 130. Visible spring
anti-vibration pads for the unit and the ground mounting holes. For
on site fitting by the installer.
Condenser coil protective coating :
- aluminium fins with hydrophilic coating,
- aluminium fins with polyurethane coating.
High pressure fans : For models 40 to 120 with ductable fans
providing external static pressure of 80 Pa (models 40 to 60) and
100 Pa (models 70 to 120).
400 V / 230 V transformer : For models 40 to 80 with electrical
supply without neutral.
Buffer tank kit : For air conditioning applications where it is not
possible to comply with the water volume ratio of 2.5 l / kW. This kit
comprises a factory-fitted module, mounted under the unit, and
supplied with the external hydraulic pipe work to be fitted on site.
The hydraulic module is fully encased in galvanised steel panels,
painted the same colour as the unit, and comprises a buffer tank,
fully insulated with 30 kg / m
3
density cellular polyurethane foam.
As standard, the buffer tank is equipped with anti-freeze protection
in the form of an immersion heater.
Remote control terminal : Hard-wired control enabling the unit’s
Start / Stop functions to be controlled remotely.
Phase monitor : Factory-fitted option enabling the compressor’s
rotational direction to be checked and to stop the unit if the mini-
mum voltage threshold is reached.
Low ambient kit (-18 °C) : Factory-fitted option available for
models 40 to 130.
Chiller sequencer : Supplied loose, it allows a control up to 4
units.
HP and LP manometers : Supplied loose.
Water isolating valves : Supplied loose.
Packaging : Sea worth or wooden crate.
Evaporator
- Direct expansion type, made of brazed stainless steel plates.
- The evaporator is surrounded by an electrical heating
resistance and insulated with cellular polyurethane foam to
provide anti-freeze protection down to an ambient temperature
of - 20 °C.
Air condenser
- Comprising a heat exchanger coil equipped with aluminium fins
mechanically crimped on to copper tubes.
Fan motor assembly
- Helicoidal type fans with direct drive by a dual speed motor
(Protection Index : IP 54), equipped with automatic reset internal
high temperature protection.
- Two 610 mm diameter horizontal flow fans on models 20 to 35,
one 800 mm diameter vertical flow fan on models 40 to 80 and
two 800 mm diameter vertical flow fans on models 90 to 130.
Each fan is equipped with a fan blade protection grille.
Refrigerant circuit
The refrigerant circuit comprises all the required components such
as filter-dryer, sight glass with moisture indicator, 4-way reverse
cycle valve and thermostatic expansion valve. It also comprises
high and low pressure sensors, as well as sensors for inlet and
outlet water temperatures and a discharge temperature sensor.
To facilitate maintenance operations, the low and high pressure
sections of the refrigerant circuit are equipped with pressure tapping
points.
All the refrigerant components and pipe work are brazed, thus
eliminating any risks of leakage and ensuring total, long lasting
circuit tightness.
Pressure transducers replace the HP (High Pressure) and LP
(Low Pressure) pressostats, along with their capillary tubes
(principal source of leaks).
The refrigerant circuit is optimised to operate with HFC 407C
refrigerant fluid.
Electrical panel
Access to the electrical panel is possible after having taken off the
panels, removable by just releasing quarter turn locks or screws.
The electrical panel of models 90 to 130 rotates to allow an easy
access for inspection inside the unit.
On models 20 to 35, the following equipment is mounted on the
power circuit side of the electrical panel : a power supply connection
terminal block - 400 V / 3 Ph / 50 Hz + Neutral, a main switch,
contactors and thermal relays for the compressors and the
hydraulic pump (if fitted). On the control circuit side of the panel,
the ILTC control electronic circuit board with its 230 V single phase
power supply is mounted.
On models 40 to 130, the following equipment is mounted on the
power circuit side of the electrical panel : a power supply connection
terminal block - 400 V / 3 Ph / 50 Hz + Neutral (models 40 to 80) or
400 V / 3 Ph / 50 Hz (models 90 to 130), a main switch, a main
terminal block, a distribution terminal block, the compressors
contactors, the thermal relays and contactors for the fans, and
the hydraulic pump (if fitted). On the control circuit side of the
panel, the ILTC control electronic circuit board with its 230 V single
phase power supply is mounted.
Содержание
- Air to water reverse cycle heat pumps 1
- Aqh 20 to 130 1
- Aqu logic 1
- A maximum of technology 2
- Built to last 2
- Cabinet and structure 2
- Compressors 2
- Energy savings all year round 2
- Features and benefits 2
- General specifications 2
- Increased performance 2
- Optimized defrost 2
- Page 2 2
- Quick and easy installation at minimal cost 2
- Why choose iltc technology 2
- Accessories and options 3
- Air condenser 3
- Electrical panel 3
- Evaporator 3
- Fan motor assembly 3
- General specifications continued 3
- Integrated hydraulic module 3
- Other standard equipment 3
- Page 3 3
- Refrigerant circuit 3
- Iltc control system 4
- Iltc control system description 4
- Page 4 4
- Remote unit management 4
- Safety 4
- Cooling mode 5
- Heating mode 5
- Models 20 to 80 5
- Page 5 5
- Refrigerant flow diagrams 5
- Cooling mode 6
- Heating mode 6
- Models 90 to 130 6
- Page 6 6
- Refrigerant flow diagrams continued 6
- Operating temperature range cooling mode 7
- Operating temperature range heating mode 7
- Page 7 7
- Selection example 7
- Selection guide 7
- Altitude correction factors 8
- Chilled water inlet outlet temperature correction factors 8
- Condenser fouling factors 8
- Evaporator fouling factors 8
- Hydraulic circuit water volume 8
- Maximum volume in litres for comfort air conditioning applications 8
- Minimum volume for comfort air conditioning applications 8
- Operating limits cooling mode operating limits heating mode 8
- Selection guide continued 8
- Technical characteristics hfc 407c 9
- Technical characteristics hfc 407c continued 10
- Lp a sound pressure levels 11
- Lw a sound power levels 11
- Protection devices 11
- Technical characteristics hfc 407c continued 11
- Compressors 12
- Electrical characteristics hfc 407c 12
- Evaporator heating resistance 12
- Standard condenser fans 12
- Standard pumps 12
- Unit with hydraulic module 12
- Unit without hydraulic module 12
- Performance data in cooling mode hfc 407c 13
- Performance data in cooling mode hfc 407c continued 14
- Performance data in heating mode hfc 407c 15
- Performance data in heating mode hfc 407c continued 16
- Cooling mode heating mode 17
- Models 20 25 30 35 17
- Models 40 50 60 70 80 17
- Unit external static pressure 17
- Cooling mode heating mode 18
- Models 90 to 130 18
- Unit external static pressure continued 18
- 10 15 20 30 40 50 correction factors 1 2 1 0 0 8 0 7 0 5 0 3 0 1 water average temperature c 19
- Heat exchanger water pressure drop 19
- Models 20 25 30 35 19
- Models 40 50 60 70 80 19
- Page 19 19
- Water flow l s 19
- Heat exchanger water pressure drop continued 20
- Models 90 to 130 20
- Dimensions aqu logic aqh sizes 20 25 30 and 35 21
- Front view side view 21
- Page 21 21
- Top view 21
- Dimensions aqu logic aqh size 40 22
- Front view side view 22
- Page 22 22
- Top view 22
- Dimensions aqu logic aqh sizes 50 60 70 and 80 23
- Front view side view 23
- Page 23 23
- Top view 23
- A water inlet ø2 gas b water outlet ø2 gas c ancillary electric cables entry d power supply cables entry 24
- Dimensions aqu logic aqh size 90 24
- Front view side view 24
- Location of anti vibration mounts dimensions in mm 24
- Page 24 24
- Side view 24
- Top view 24
- A water inlet ø2 gas b water outlet ø2 gas c ancillary electric cables entry d power supply cables entry 25
- Dimensions aqu logic aqh sizes 100 110 120 and 130 25
- Front view side view 25
- Location of anti vibration mounts dimensions in mm 25
- Page 25 25
- Side view 25
- Top view 25
- Aqu logic 20 to 35 aqu logic 40 to 80 26
- Aqu logic 90 to 130 26
- Minimum clearance around the unit 26
- Page 26 26
- A c e marketing 28
- Ace klimatechnik gmbh 28
- Iber elco s a 28
- Itelco clima srl 28
Похожие устройства
- Airwell AQH 120 Техническое описание
- 1Marka ELEGANCE 165x70 Инструкция по эксплуатации
- Airwell AQH 130 Инструкция по эксплуатации
- Airwell AQH 130 Техническое описание
- 1Marka ELEGANCE 170x70 Инструкция по эксплуатации
- 1Marka MEDEA 150x70 Инструкция по эксплуатации
- 1Marka CALYPSO 170x75 Инструкция по эксплуатации
- 1Marka AGORA 170x75 Инструкция по эксплуатации
- 1Marka DINAMIKA 170x80 Инструкция по эксплуатации
- 1Marka DINAMIKA 180x80 Инструкция по эксплуатации
- 1Marka KORSIKA 190x100 Инструкция по эксплуатации
- 1Marka TAORMINA 180x90 Инструкция по эксплуатации
- 1Marka CASSANDRA 140x140 Инструкция по эксплуатации
- 1Marka IBIZA 150x150 Инструкция по эксплуатации
- 1Marka PALERMO 150x150 Инструкция по эксплуатации
- 1Marka LUXE 155x155 Инструкция по эксплуатации
- 1Marka PICCOLO 150x75 Инструкция по эксплуатации
- 1Marka CATANIA 150x105 Инструкция по эксплуатации
- 1Marka CATANIA 160x110 Инструкция по эксплуатации
- 1Marka ASSOL 160x95 Инструкция по эксплуатации