Installation
This pump is designed to sit level on its base or be fitted level to
a vertical surface using bracket supplied. Ensure that there are
no kinks or trapped parts in the piping, which must have an
inside diameter of 6mm. Fix the pipe with hose clamp provided
to the pump outlet.
Important
Pump should be filled with water until motor runs, check
for leaks and proper discharge of water. For further help
contact Aspen Pumps. Not suitable for condensing boilers.
Service Guide
Flush the pump through with anti-bacterial wash every six
months to avoid sludge build-up in the pump housing.
NB:
The contractors should satisfy themselves that any
chemicals used are compatible with the working of
the pump.
NB.
Only for in pan use
Ø 19mm or less –
pierce lid
Ø 20mm or more –
Slice off top
Performance
Cut away 1/4 of
grey inlet bung to
allow ventilating
Description :
Cette pompe a été conçue pour relever des condensats jusqu’à
une hauteur de 10 mètres. La pompe est équipée d’un contact
d’alarme pour pouvoir couper le climatiseur en cas de défail-
lance de la pompe.
Caracteristiques :
• Capacité du bac : 0,24 L
• Hauteur maximum de relevage : 10 mètres
• Capacité maximum de pompage d’eau : 50 litres / heure
• Equipée d’un contact d’alarme
• Installation possible au sol, en mural ou sur le support fourni
• Câble de connexion de 1 mètre
• Plastique résistant au feu
• Le capuchon souple d’entrée des condensats peut être
percé pour s’adapter à la plupart des tubes d’écoulement
de condensats.
• Refoulement 6 mm
• Température maximum des condensats : 40°C
• Niveau sonore à 1 mètre : 35 dB(A)
• Interrupteur de sécurité
• Tension Mono 230 V, 19 W, 0,15A
• Contact d’alarme 3A
• Dimensions (avec support) Longueur 180 mm x Largeur
90 mm x Hauteur 70 mm
• Weight: Poids : 0,57 kg
• Norme: IP67
Donnees Electriques :
• 230 V AC, 19 W
• Mono 50/60 Hz
• Régulation par flotteur (3 niveaux) avec niveau d’alarme : 3A
• Double isolation (Appareil de classe 2)
Connexions Electriques :
Permanent / Phase : Marron
Neutre : Bleu
Contact d’alarme : 2 x Noir
Il est impératif de TOUJOURS utiliser le coupe-circuit de
sécurité (contact alarme).
Notice Pompe Mini Tank
Cont.
MAX 3 AMP
Phase
Phase
Neutre
Ter re
Phase
Neutre
Ter re
Neutre
Phase
Neutre
Terre
Phase
Neutre
Terre
Pompe
Unité Intérieure
Bus
Unité Extérieure
1
2
3
4
1
2
3
4
FR
Suitable for in-pan use.
Min 32mm
15
12
9
6
3
0
0 5 10 15 20 25 30 35 40 45 50
Litres per heure
Metres head
* 10 metres max recommended head
*
Содержание
- Conseil en matière de maintenance 1
- Description 1
- Electrical connections 1
- Important 1
- Installation 1
- Mini tank pump instructions 1
- Performance 1
- Power supply 1
- Technical specification 1
- Caracteristiques 2
- Connexions electriques 2
- Description 2
- Donnees electriques 2
- Important 2
- Installation 2
- Notice pompe mini tank 2
- Performance 2
- Service guide 2
Похожие устройства
- Aspen pumps Hi-flow 1L Инструкция по эксплуатации
- Aspen pumps Hi-flow 2L Инструкция по эксплуатации
- Atmos DC 15 EPL Инструкция по эксплуатации
- Atmos DC 18 SPL Инструкция по эксплуатации
- Atmos DC 25 SPL Инструкция по эксплуатации
- Atmos DC 32 SPL Инструкция по эксплуатации
- Atmos D 15 Инструкция по эксплуатации
- Atmos D 15 Техническое описание
- Atmos D 20 Инструкция по эксплуатации
- Atmos D30 Инструкция по эксплуатации
- Atmos D30 Техническое описание
- Atmos D 20 Техническое описание
- Atmos D 15 P Инструкция по эксплуатации
- Atmos D 15 P Техническое описание
- Atmos D 20 P Инструкция по эксплуатации
- Atmos D 20 P Техническое описание
- Atmos D 30 P Инструкция по эксплуатации
- Atmos D 30 P Техническое описание
- Atmos D 45 P Инструкция по эксплуатации
- Atmos D 45 P Техническое описание