Beko ET 5604 GIX [65/68] Gas tonvertion

Содержание

Part 9 Gas tonvertion Rodined Tap Flow Natural Gas and LPG You can Removal of the control panel convert by changing the gas source 1 Open the front door Your cooker can operate both and the top burner oven and grill injectors The replacement procedure of the injectors are explained below Call authorized Service for gas convertion 2 Unscrew the two screws of the control panel and take the control panel bottom sheet 3 Release the control panel from the two notches at the top slightly pull it to the bottom front and keep it free Replacement of the top burner injector with its cables connected Ignite the burner that should be Take off the burner head and adjusted turn the knob to the reduced burner cap before starting this position pull and take the knob off procedure Then 4 With a screwdriver make the tap 1 Remove the injector inside the reduced flow adjustment from the top burner with a suitable bit injector that is on the gas tap only Later install the new injector by the head is visible with the bolt covering the injector threads shape should be 6 7mm with leakagt If the flame is higher than the desired preventing material Flame failure device It is sufficient to tight to screw position turn the screw clockwise If completely in butane propane gas its smaller to the opposite For the natural gas you should turn For the last control of the burning of the screw counter clockwise the cooker bring the cooker high once The normal length of a straight flame and reduced positions and flame in the reduced position 31 check whether the flame is on or off