Buderus Logalux PR 1000-120 [4/104] Standard delivery

Buderus Logalux PNR 1000-120 E(W) [4/104] Standard delivery
2
Information about the appliance
Logalux – 6 720 649 880 (2011/03)
4
2 Information about the
appliance
2.1 Product description
The buffer cylinder vessel is delivered fully assembled.
The thermal insulation and temperature sensors have to
be fitted.
There are two types of buffer cylinder
(Æ Fig. 4, page 101).
Buffer cylinder
Logalux PR 500/750/1000-80
Logalux PR 500/750/1000-120
Solar buffer cylinder
Logalux PNR 500/750/1000-80 E(W)
Logalux PNR 500/750/1000-120 E(W)
Both types of cylinder are available with 80 mm PU
flexible foam thermal insulation or 120 mm polyester
fleece thermal insulation.
The buffer cylinder is made from steel and equipped with
a temperature-sensitive return feed.
A back boiler or solid fuel boiler can be integrated via the
connections for the boiler and heating circuits.
The Logalux PNR solar buffer cylinder additionally has a
connection for a solar thermal system and an electrical
immersion heater (Æ Fig. 4, page 101).
2.2 Standard delivery
Buffer cylinder, general
Cylinder
Technical documentation
Thermal insulation
Cylinder cover
Upper and lower thermal insulation discs
Flexible clamps for temperature sensors.
Buffer cylinder with 80 mm thermal insulation
Thermal insulation for immersion heater connection
(
only PNR 500/750/1000-80 E(W))
Connection covers
Buffer cylinder with 120 mm thermal insulation
Thermal insulation for immersion heater connection
(only PNR 500/750/1000-120 E(W))
Connection covers
2.3 Correct use
Due to their large volume, the Logalux PR buffer cylinders
and Logalux PNR solar buffer cylinders are designed for
central heating backup.
These buffer cylinders may only be filled with heating
water and used in sealed heating systems. The cylinders
are not suitable for use with potable water.
The buffer cylinders can be used for indirect DHW
heating via a freshwater station.
2.4 Tools, materials and auxiliary
equipment
A pallet truck, forklift truck or crane is required for
transportation.
2.5 Specification
2.5.1 Logalux PR buffer cylinder dimensions and
connections
2.5.2 Logalux PNR solar buffer cylinder
dimensions and connections
Maximum permissible values Logalux PR500/750/1000
Maximum operating pressure bar 3
Maximum operating temperature, heating
water
°C 110
Table 3 PR maximum permissible values
Dimensions and
surface load
PR 500 PR 750 PR 1000
Height when
tilted
mm 1780 1740 1740
Total weight
when filled
kg 630 897 1176
Weight load
per foot
kg 210 299 392
Table 4 Logalux PR specification
Maximum permissible values Logalux PNR500/750/1000
Maximum operating pressure, solar indirect
coil
1)
1) Subject to the way the appliance is integrated into the solar
thermal system, individual protection may be required (safety
valve, expansion vessel).
bar 8
Maximum operating pressure, heating water bar 3
Maximum operating temperature, solar
indirect coil
°C 160
Maximum operating temperature, heating
water
°C 110
Table 5 PNR maximum permissible values