Toshiba RAS-18 S3KHS-EE/RAS-18 S3AHS-EE [3/8] Dry operation

Toshiba RAS-18 S3KHS-EE/RAS-18 S3AHS-EE [3/8] Dry operation
To automatically restart the air conditioner after the power failure (Power of the
unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for
5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel
the operation. (3 beep sound but OPERATION lamp does not blink)
In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.
AUTO RESTART OPERATION
12
Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
Clean the indoor unit and the remote control with a wet cloth when needed.
No benzine, thinner, polishing powder or chemically-treated duster.
MAINTENANCE
13
Preparing Filters
1. Open the air inlet grille and remove the air fi lters.
2. Attach the fi lters. (see detail in the accessory sheet).
Loading Batteries (when use wireless operation.)
1. Remove the slide cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Remote Control Reset
1. Remove the batteries.
2. Press
.
3. Insert the batteries.
1 Infrared signal emitter
2 Start/Stop button
3 Mode select button (MODE)
4 Temperature button (TEMP)
5 Fan speed button (FAN)
6 Swing louver button (SWING)
7 Set louver button (FIX)
8 Off timer button (OFF)
9 High power button (Hi-POWER)
! Economy button (ECO)
" Clear button (CLEAR)
# Check button (CHECK)
To automatically select cooling, heating or fan only operation
1. Press
MODE
: Select A.
2. Press
: Set the desired temperature.
3. Press
FAN
: Select AUTO, LOW , LOW+ , MED , MED+ , or
HIGH
.
For dehumidifi cation, a moderate cooling performance is controlled automatically.
1. Press
MODE
: Select Dry .
2. Press : Set the desired temperature.
To automatically control room temperature and airfl ow for faster cooling or heating
operation (except in DRY and FAN ONLY mode)
Press
Hi POWER
: Start and stop the operation.
In case of the misplaced or discharged remote control
Pressing the RESET button, the unit can start or
stop without using the remote control.
Operation mode is set on AUTOMATIC operation,
preset temperature is 24°C and fan operation is
automatic speed.
Set the timer when the air conditioner is operating.
To automatically control room to save energy (except in DRY and FAN ONLY mode)
Press : Start and stop the operation.
Note: Cooling operation; the set temperature will increase automatically 1 degree/
hour for 2 hours (maximum 2 degrees increase). For heating operation the
set temperature will decrease.
1. Press
MODE
: Select Cool , Heat , or Fan only .
2. Press
: Set the desired temperature.
Cooling: Min. 17°C, Heating: Max. 30°C, Fan Only: No temperature indication
3. Press
FAN
: Select AUTO, LOW , LOW+ , MED , MED+ ,
or HIGH .
COOLING / HEATING / FAN ONLY OPERATION
6
DRY OPERATION
7
Hi-POWER OPERATION
8
ECO OPERATION
9
TEMPORARY OPERATION
10
TIMER OPERATION
11
PREPARATION BEFORE USE
2
1
Press
FIX
: Move the louver in the
desired vertical direction.
2
Press
SWING
: Swing the air
automatically and press again to stop.
3
For horizontal direction, adjust manually.
Note:
Do not move the louver manually by others.
The louver may automation positioning by some operation mode.
AIR FLOW DIRECTION
3
REMOTE CONTROL
4
AUTOMATIC OPERATION
5
4
5
"
!
1
2
7
8
#
3
9
6
Setting the OFF timer
1
Press
OFF
for enter OFF timer setting.
2
Press for select desired OFF timer. (0.5 - 12 hrs)
3
Press
OFF
for set OFF timer.
4
Press
OFF
again for cancel OFF timer.
EN
FR
IT
DE
PT
PL
CZ
RU
CR
HU
TR
NL
GR
SV
FI
NO
DK
RO
BG
EE
LV
SK
SI
TSB 1110655140_EN_RU.indb 2TSB 1110655140_EN_RU.indb 2 11/20/57 BE 2:05 PM11/20/57 BE 2:05 PM