Toshiba N3KV-E RAS-10N3KV-E Белый [3/5] Self cleaning operation
![Toshiba N3KV-E RAS-10N3KV-E Белый [3/5] Self cleaning operation](/views2/1225714/page3/bg3.png)
TEMPORARY OPERATION
11
In case of the misplaced or discharged remote control
• Pressing the RESET button, the unit can start or
stop without using the remote control.
• Operation mode is set on AUTOMATIC operation,
preset temperature is 25°C and fan operation is
automatic speed.
TIMER OPERATION
12
Daily timer allows the user to set both the ON & OFF timers and will be
activated on a daily basis.
Setting Daily Timer
Setting the ON Timer Setting the OFF Timer
1
Press : Set the desired ON
timer.
Press : Set the desired
OFF timer.
2
Press : Set the timer. Press : Set the timer.
3
Press : Cancel the timer. Press : Cancel the timer.
1
Press
: Set the ON timer.
3
Press .
2
Press
: Set the OFF timer.
4
Press button during
the ( or ) mark fl ashing.
• During the daily timer is activating, both arrows ( , ) are indicated.
Note:
• Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur.
• The setting will be saved for the next same operation.
PRESET OPERATION
13
Set your preferred operation for future use. The setting will be memorized by
the unit for future operation (except airfl ow direction).
1. Select your preferred operation.
2. Press and hold
for 3 seconds to memorize the setting.
The P mark displays.
3. Press : Operate the preset operation.
AUTO RESTART OPERATION
14
To automatically restart the conditioner after the power failure (Power of the
unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to
set the operation. (3 beep sound and OPERATION lamp blink 5 time/
sec for 5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
• In case of ON timer or OFF timer are set, AUTO RESTART
OPERATION does not activate.
To operate at super low fan speed for quiet operation (except in DRY mode)
Press
48,(7
: Start and stop the operation.
Note: Under certain conditions, QUIET operation may not provide adequate
cooling or heating due to low sound features.
To save energy while sleeping, automatically control air fl ow and
automatically turn OFF.
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
QUIET OPERATION
15
COMFORT SLEEP OPERATION
16
SELF CLEANING OPERATION
18
OPERATION AND PERFORMANCE
19
1. Three-minute protection feature: To prevent the unit from being
activated for 3 minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the heating
operation starts.
3. Warm air control: When the room temperature reaches the set
temperature, the fan speed is automatically reduced and the outdoor
unit will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released into
the room. When the outdoor temperature is too low, use another
recommended heating apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit
where it will not be subjected to snow drifts, accumulation of leaves or
other seasonal debris.
7. Some minor cracking sound may occur when unit operating. This is
normal because the cracking sound may be caused by expansion/
contraction of plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature Room Temperature
Heating –10°C ~ 24°C Less than 28°C
Cooling 15°C ~ 43°C 21°C ~ 32°C
Dry 15°C ~ 43°C 17°C ~ 32°C
The unit does not operate.
Cooling or Heating is abnormally low.
• The power main switch is
turned off.
• The circuit breaker is
activated to cut off the power
supply.
• Stoppage of electric current
• ON timer is set.
• The fi lters are blocked with dust.
• The temperature has been set
improperly.
• The windows or doors are opened.
• The air inlet or outlet of the outdoor
unit is blocked.
• The fan speed is too low.
• The operation mode is FAN or DRY.
TROUBLESHOOTING (CHECK POINT)
20
REMOTE CONTROL A-B SELECTION
21
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold button on the Remote Control by the tip of the
pencil. “00” will be shown on the display.
4. Press
02'(
during pushing . “B” will show on the display and
“00” will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized.
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from factory is A.
0
Firstly, turn off the circuit breaker.
Filter Reset (Some models only)
FILTER lamp lights on; the fi lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit or the FILTER
button on the remote control.
Indoor Unit and Remote Control
• Clean the indoor unit and the remote control with a wet cloth when
needed.
• No benzine, thinner, polishing powder or chemically-treated duster.
MAINTENANCE
17
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during “Cool” or “Dry” mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
more 2 times
within 30 seconds.
EN
12
1113950109_EN.indd 31113950109_EN.indd 3 8/8/12 11:08 AM8/8/12 11:08 AM
Содержание
- Air conditioner split type 1
- Indoor unit 1
- Outdoor unit 1
- Owner s manual 1
- Air flow direction 2
- Automatic operation 2
- Caution 2
- Cooling heating fan only operation 2
- Danger 2
- Dry operation 2
- Eco operation 2
- Hi power operation 2
- Indoor unit display 2
- One touch 2
- Precautions for safety 2
- Preparation before use 2
- Remote control 2
- Warning 2
- Auto restart operation 3
- Comfort sleep operation 3
- Maintenance 3
- Operation and performance 3
- Preset operation 3
- Quiet operation 3
- Remote control a b selection 3
- Self cleaning operation 3
- Temporary operation 3
- Timer operation 3
- Troubleshooting check point 3
- Hапраbлеhие пotoка boздуха 4
- Mерьi безoпаchoctи 4
- Paбota b peжиme cушки 4
- Аbtomаtичеcкий режиm 4
- Диcплей bhуtреhнегo блoка 4
- Кнопка onе touch 4
- Пoдгotobка к иcпoльзobаhию 4
- Предoctережеhие 4
- Предупреждеhие 4
- Пульт дистанционного управления 4
- Рабotа b режиmе hi рowеr 4
- Рабotа b режиmе oхлаждеhия hагреbаhия bеhtилирobаhия 4
- Рабotа b режиmе еco 4
- Peжиm camooчиctки 5
- Tехhичеcкoе oбcлужиbаhие 5
- _ru indd 3 1113950109_ru indd 3 8 8 12 11 09 am 8 8 12 11 09 am 5
- Аbtomаtичеcкий пobtoрhый пуcк 5
- Выбор а в на пульте ду 5
- Ежедневный таймер позволяет пользователю установить оба таймера включения и выключения и активируется ежедневно установка ежедневного таймера 5
- Когда активирован ежедневный таймер отображаются обе стрелки примечание пульт ду должен находиться на расстоянии приемлемом для передачи сигнала на внутренний блок в противном случае может иметь место задержка срабатывания длительностью до 15 минут эта настройка будет сохранена для следующей аналогичной операции 5
- Нагревание 10 c 24 c ниже 28 c охлаждение 15 c 43 c 21 c 32 c сушка 15 c 43 c 17 c 32 c 5
- Нажмите и удерживайте кнопку 2 нажмите и удерживайте кнопку нажатой в течение 3 секунд для сохранения настройки отобразится символ p 5
- Нажмите кнопку 3 нажмите кнопку для начала работы в режиме предварительных установок 5
- Рабotа b режиmаx темрorаry 5
- Рабotа b режиmе tайmера 5
- Режим наружная температура комнатная температура 5
- Температура 5
- Установите желаемый режим которым впоследствии вы можете воспользоваться настройка будет сохранена в памяти устройства для использовании при последующей работе за исключением направления потока воздуха 1 выберите желаемый режим 5
- Фуhкции и их иcпoлнеhие 5
Похожие устройства
- Hisense NEO Premium Classic A AS-30HR4SQBTG Белый Инструкция по эксплуатации
- Hisense NEO Classic A AS-07HR4SYDDH Белый Инструкция по эксплуатации
- Hisense SMART DC Inverter AS-18UR4SUADBG Белый Инструкция по эксплуатации
- Rovex RCF RCF-36HR1/CCU-36HR1 Белый Инструкция по эксплуатации
- Akvilon NC NC-12 Белый Инструкция по эксплуатации
- Oasis CL-28 Белый Инструкция по эксплуатации
- Hisense NEO Classic A AS-07UR4SYDDB1G Белый Инструкция по эксплуатации
- Hisense ECO Classic A AS-24HR4SFADH Белый Инструкция по эксплуатации
- Hisense NEO Premium Classic A AS-13HR4SVDTG Белый Инструкция по эксплуатации
- Toshiba SKHP-ES RAS-07SKHP-ES / RAS-07S2AH-ES Белый Инструкция по эксплуатации
- Jax Sydney АСК-09НE Белый Инструкция по эксплуатации
- Alecord AL-12 Белый Инструкция по эксплуатации
- Electrolux Portofino EACS-12HP/N3 Белый Инструкция по эксплутации
- Haier Lightera On-Off HSU-24HT203/R2/HSU-24HUN103/R2 Белый Инструкция по эксплуатации
- Dantex ECO RK-18ENT2 Белый Инструкция по эксплуатации
- Haier HSU-07HT103/R2/HSU-07HUN203/R2 Белый Инструкция по эксплуатации
- Jax Uluru ACI-26HE Белый Инструкция по эксплуатации
- Haier HSU-12HNM103/R2/HSU-12HUN103/R2 Белый Инструкция по эксплуатации
- Jax Sydney АСК-07HE Белый Инструкция по эксплуатации
- Hisense NEO Classic A AS-07HR4SYDTG Белый Инструкция по эксплуатации