D-Link DGS-1510-28XMP/ME [169/718] Chapter 17 connectivity fault management cfm extension command list

D-Link DGS-1510-28LP/ME [169/718] Chapter 17 connectivity fault management cfm extension command list
DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
165
Chapter 17
Connectivity Fault Management
(CFM) Extension Command List
config cfm ais md [<string 22> | md_index <uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-
4294967295>] mepid <int 1-8191> {period [1sec | 1min] | level <int 0-7> | state [enable | disable]}(1)
config cfm lock md [<string 22> | md_index <uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-
4294967295>] mepid <int 1-8191> {period [1sec | 1min] | level <int 0-7> | state [enable | disable]}(1)
show cfm {[md [<string 22> | md_index <uint 1-4294967295>] {ma [<string 22> | ma_index <uint 1-
4294967295>] {mepid <int 1-8191>}} | mepname <string 32>]}
show cfm fault {md [<string 22> | md_index <uint 1-4294967295>] {ma [<string 22> | ma_index <uint 1-
4294967295>]}}
cfm lock md [<string 22> | md_index <uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]
mepid <int 1-8191> remote_mepid <int 1-8191> action [start | stop]
cfm loopback <macaddr> [mepname <string 32> | mepid <int 1-8191> md [<string 22> | md_index <uint 1-
4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]] {num <int 1-65535> | [length <int 0-1500>
| pattern <string 1500>] | pdu_priority <int 0-7>}
17-1 config cfm ais md
Description
This command is used to configure the parameters of the AIS function on a MEP.
Format
config cfm ais md [<string 22> | md_index <uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-
4294967295>] mepid <int 1-8191> {period [1sec | 1min] | level <int 0-7> | state [enable | disable]}(1)
Parameters
<string 22> - Enter the maintenance domain name. The maximum length is 22 characters.
md_index - Specifies the maintenance domain index.
<uint 1-4294967295> - Enter the maintenance domain index value here. This value must be between 1 and
4294967295.
ma - Specifies the maintenance association name.
<string 22> - Enter the maintenance association name. The maximum length is 22 characters.
ma_index - Specifies the maintenance association index.
<uint 1-4294967295> - Enter the maintenance association index value here. This value must be between 1
and 4294967295.
mepid - Specifies the MEPID.
<int 1-8191> - Enter the MEP MEPID between 1 and 8191.
period - Specifies the transmitting interval of the AIS PDU.
1sec - Specifies that the transmitting interval period will be set to 1 second.
1min - Specifies that the transmitting interval period will be set to 1 minute.
level - Specifies the client level ID to which the MEP sends AIS PDU. The default client MD level is the MD level
that the most immediate client layer MIPs and MEPs exist on.
<int 0-7> - Enter the client level ID used here. This value must be between 0 and 7.