Indoor Unit
Installation
Indoor Unit Installation
3
Indoor Unit Parts
(within indoor unit)
Drain pipe
Drain pump
Air outlet
Air inlet
Display panel
Front grille
Louver
Refrigerant pipe
Fig. 3.1
Safety Precautions
WARNING
Securely install the indoor unit on a
structure that can sustain its weight. If the
structure is too weak, the unit may fall
causing personal injury, unit and property
damage, or even death.
Install the indoor unit at a height of more
than 2.5m (8’) above the floor.
DO NOT install the indoor unit in a
bathroom or laundry room as excessive
moisture can short the unit and corrode
the wiring.
CAUTION
• Install the indoor and outdoor units, cables
and wires at least 1m (3.2’) from televisions
or radios to prevent static or image
distortion. Depending on the appliances, a
1m (3.2’) distance may not be sufficient.
If the indoor unit is installed on a metal
part of the building, it must be grounded.