Configuration Guide
999
Switch(config)#show rmon event
Index User Description Type Owner State
----- ---- ----------- ---- ----- -----
1 admin rising-notify Notify monitor Enable
Switch(config)#end
Switch#copy running-config startup-config
5.2.4 Configuring Alarm
Step 1 configure
Enter global configuration mode.
Step 2 rmon alarm
index
stats-index
sindex
[ alarm-variable { revbyte | revpkt | bpkt | mpkt | crc-
align | undersize | oversize | jabber | collision | 64 | 65-127 | 128-255 | 256-511 | 512-1023
| 1024-10240}] [ s-type {absolute | delta}] [ rising-threshold
r-hold
] [ rising-event-index
r-event
] [ falling-threshold
f-hold
] [ falling-event-index
f-event
] [ a-type {rise | fall | all} ] [
owner
owner-name
] [ interval
interval
]
Configuring RMON alarm entries.
index:
Enter the index of the alarm entry from 1 to12 in the format of 1-3 or 5.
sindex:
Set the index of the related statistics entry from 1 to 65535.
revbyte | revpkt | bpkt | mpkt | crc-align | undersize | oversize | jabber | collision | 64 | 65- 127
| 128-255 | 256-511 | 512-1023 | 1024-10240:
Choose an alarm variable to monitor. The
switch will monitor the specified variable in sample intervals and act in the set way when the
alarm is triggered. The default variable is revbyte.
revbyte means total received bytes; revpkt means total received packets; bpkt means total
broadcast packets. mpkt means total multicast packets; crc-align means packets that range
from 64 to 1518 bytes and contain FCS Error or Alignment Error; undersize means packets
that are smaller than 64 bytes; oversize means packets that are larger than 1518 bytes;
jabber means packets that are sent when port collisions occur; collision means the collision
times in the network segment; 64 | 65-127 | 128-255 | 256-511 | 512-1023 | 1024-10240
means total packets of the specified size.
absolute | delta
:
Choose the sampling method of the specified variable. The default is
absolute. In the absolute mode, the switch compares the sampling value against the preset
threshold; in the delta mode, the switch obtains the difference between the sampling values
of the current interval and the previous interval, and then compares the difference against
the preset threshold.
r-hold
:
Enter the rising threshold from 1 to 2147483647; the default is 100.
r-event:
Enter the Event entry index from 1 to 12 to bind it to the rising threshold. The event
entry will be triggered when the sampling value exceeds the preset threshold. The Event
entry specified here should be enabled first.
f-hold:
Enter a falling threshold from 1 to 2147483647; the default is 100.