Cyberpower OR600ELCDRM1U [2/2] Or600elcdrm1u or1000elcdrm1u or1500elcdrm1u

Cyberpower OR600ELCDRM1U [2/2] Or600elcdrm1u or1000elcdrm1u or1500elcdrm1u
TECHNICAL SPECIFICATIONS
OR600ELCDRM1U
Line-interactive
GreenPower UPS™ Bypass Technology
230
160 ~ 263
50 ± 3, 60 ± 3
Auto-sensing
10
IEC C14
600
360
Simulated Sine Wave
230 ± 10%
50 ± 1%, 60 ± 1%
Single Boost
Internal Current Limiting, Circuit Breaker
6
IEC C13 x 6
4
2
4
13
4
8
Yes
Yes
Sealed Lead-acid
RBP0019
1
405
Yes
1-in, 1-out
Yes
1
Dry Contact
PowerPanel® Business Edition
Yes - with optional RMCARD205
Rack
433 x 44 x 235
8.1
1
0 ~ 40
0 ~ 95
20
CE, EAC, RCM
Yes
OR1000ELCDRM1U
Line-interactive
GreenPower UPS™ Bypass Technology
230
160 ~ 263
50 ± 3, 60 ± 3
Auto-sensing
10
IEC C14
1000
600
Simulated Sine Wave
230 ± 10%
50 ± 1%, 60 ± 1%
Single Boost
Internal Current Limiting, Circuit Breaker
6
IEC C13 x 6
4
2
4
14
3.5
8
Yes
Yes
Sealed Lead-acid
RBP0025
1
810
Yes
1-in, 1-out
Yes
1
Dry Contact
PowerPanel® Business Edition
Yes - with optional RMCARD205
Rack
433 x 44 x 389
16.1
1
0 ~ 40
0 ~ 95
24
CE, EAC, RCM
Yes
OR1500ELCDRM1U
Line-interactive
GreenPower UPS™ Bypass Technology
230
160 ~ 263
50 ± 3, 60 ± 3
Auto-sensing
10
IEC C14
1500
900
Simulated Sine Wave
230 ± 10%
50 ± 1%, 60 ± 1%
Single Boost
Internal Current Limiting, Circuit Breaker
6
IEC C13 x 6
4
2
4
11
2.5
8
Yes
Yes
Sealed Lead-acid
RBP0026
1
810
Yes
1-in, 1-out
Yes
1
Dry Contact
PowerPanel® Business Edition
Yes - with optional RMCARD205
Rack
433 x 44 x 485
19.4
1
0 ~ 40
0 ~ 95
24
CE, EAC, RCM
Yes
Model Name
General
UPS Topology
Energy Saving Technology
Input
Nominal Input Voltage (Vac)
Input Voltage Range (Vac)
Input Frequency (Hz)
Input Frequency Detection
Rated Input Current (A)
Input Connector Type
Output
Capacity (VA)
Capacity (Watts)
On Battery Waveform
On Battery Voltage(s) (Vac)
On Battery Frequency (Hz)
Automatic Voltage Regulation (AVR)
Overload Protection
Outlet(s) - Total
Outlet Type
Outlet(s) - Battery & Surge Protected
Outlet(s) - Surge-Only Protected
Typical Transfer Time (ms)
Battery
Runtime at Half Load (min)
Runtime at Full Load (min)
Typical Recharge Time (Hours)
User Replaceable
Hot-Swappable
Battery Type
Replacement Battery Pack
RBP Quantity (pcs)
Surge Protection & Filtering
Surge Suppression (Joules)
EMI/RFI Filtration
Phone/Network Protection RJ11/RJ45 (Combo)
Management & Communications
LCD Panel
HID Compliant USB Port(s)
Serial Port
Power Management Software
SNMP/HTTP Remote Monitoring
Physical
Form Factor
Physical Size - UPS Module
Dimensions (WxHxD) (mm.)
Weight (kg.)
Installed Rack Height (U)
Environmental
Operating Temperature (°C)
Operating Relative Humidity (Non-condensing) (%)
Online Thermal Dissipation (BTU/hr)
Certifications
Certifications*
RoHS
*Certifications may vary according to dierent regions. Visit www.cyberpower.com for more information.
#All specifications are subject to change without notice.
Copyright © 2018 Cyber Power Systems, Inc. All rights reserved. WWW.CYBERPOWER.COM
OR600ELCDRM1U/OR1000ELCDRM1U
OR1500ELCDRM1U
Скачать