Tp-Link T1700X-16TS V3 [148/916] System vlan untagged

Tp-Link T1700X-16TS V3 [148/916] System vlan untagged
Configuring 802.1Q VLAN 802.1Q VLAN Configuration
Configuration Guide
123
Step 4 show interface switchport [fastEthernet
port
| gigabitEthernet
port
| ten-gigabitEthernet
port
| port-channel
lag-id
]
Verify the information of the port.
Step 5 end
Return to privileged EXEC mode.
Step 6 copy running-config startup-config
Save the settings in the configuration file.
The following example shows how to add the port 1/0/5 to VLAN 2, and specify its egress
rule as tagged:
Switch#configure
Switch(config)#interface ten-gigabitEthernet 1/0/5
Switch(config-if)#switchport general allowed vlan 2 tagged
Switch(config-if)#show interface switchport ten-gigabitEthernet 1/0/5
Port Te1/0/5:
PVID: 2
Acceptable frame type: All
Ingress Checking: Enable
Member in LAG: N/A
Link Type: General
Member in VLAN:
Vlan Name Egress-rule
---- ----------- -----------
1 System-VLAN Untagged
2 RD Tagged
Switch(config-if)#end
Switch#copy running-config startup-config