Tp-Link T1700X-16TS V1 [172/347] Shutdown

Tp-Link T1700X-16TS V1 [172/347] Shutdown
T1700X-16TS(config)# interface ten-gigabitEthernet 1/0/5
T1700X-16TS(config-if)# description Port_5
20.4 shutdown
Description
The shutdown command is used to disable an Ethernet port. To enable this port
again, please use no shutdown command.
Syntax
shutdown
no shutdown
Command Mode
Interface Configuration Mode (interface ten-gigabitEthernet / interface range
ten-gigabitEthernet / interface port-channel / interface range port-channel)
Privilege Requirement
Only Admin, Operator and Power User level users have access to these
commands.
Example
Disable port 1/0/3:
T1700X-16TS(config)# interface ten-gigabitEthernet 1/0/3
T1700X-16TS(config-if)# shutdown
20.5 flow-control
Description
The flow-control command is used to enable the flow-control function for a port.
To disable the flow-control function for this corresponding port, please use no
flow-control command. With the flow-control function enabled, the Ingress
Rate and Egress Rate can be synchronized to avoid packet loss in the network.
Syntax
flow-control
no flow-control
Command Mode
Interface Configuration Mode (interface ten-gigabitEthernet / interface range
ten-gigabitEthernet / interface port-channel / interface range port-channel)
156