Rigol MSO5354 [3/360] Contact us
![Rigol MSO5354 [3/360] Contact us](/views2/1472896/page3/bg3.png)
RIGOL
MSO5000 User's Guide I
Guaranty and Declaration
Copyright
© 2018 RIGOL (SUZHOU) TECHNOLOGIES INC. All Rights Reserved.
Trademark Information
RIGOL is a registered trademark of RIGOL (SUZHOU) TECHNOLOGIES INC.
Publication Number
UGA25102-1110
Software Version
00.01.01.SP3
Software upgrade might change or add product features. Please acquire the latest
version of the manual from RIGOL website or contact RIGOL to upgrade the
software.
Notices
RIGOL products are covered by P.R.C. and foreign patents, issued and pending.
RIGOL reserves the right to modify or change parts of or all the specifications
and pricing policies at the company’s sole decision.
Information in this publication replaces all previously released materials.
Information in this publication is subject to change without notice.
RIGOL shall not be liable for either incidental or consequential losses in
connection with the furnishing, use, or performance of this manual, as well as
any information contained.
Any part of this document is forbidden to be copied, photocopied, or rearranged
without prior written approval of RIGOL.
Product Certification
RIGOL guarantees that this product conforms to the national and industrial
standards in China as well as the ISO9001:2015 standard and the ISO14001:2015
standard. Other international standard conformance certifications are in progress.
Contact Us
If you have any problem or requirement when using our products or this manual,
please contact RIGOL.
E-mail: service@rigol.com
Website: www.rigol.com
Содержание
- Feb 2019 rigol suzhou technologies inc 1
- User s guide mso5000 series digital oscilloscope 1
- Contact us 3
- Copyright 3
- Guaranty and declaration 3
- Notices 3
- Product certification 3
- Publication number 3
- Software version 3
- Trademark information 3
- General safety summary 4
- Safety requirement 4
- Safety notices and symbols 6
- Measurement category 7
- Ventilation requirement 7
- Working environment 8
- Care and cleaning 9
- Environmental considerations 10
- Mso5000 series overview 11
- Document overview 12
- Main topics of this manual 12
- Content conventions in this manual 14
- Format conventions in this manual 14
- Manuals of this product 15
- Contents 16
- Chapter 1 quick start 23
- Quick start 23
- General inspection 24
- Appearance and dimensions 25
- To adjust the supporting legs 26
- To connect to ac power 26
- To prepare for use 26
- To connect the probe 27
- Turn on checkout 27
- Function inspection 30
- Probe compensation 31
- Front panel overview 32
- Rear panel overview 33
- Front panel function overview 35
- Vertical 35
- Horizontal 36
- Function menu 37
- Trigger 37
- Navigation control key 38
- Quick key shortcut key 38
- Function arbitrary waveform generator setting 39
- Run stop 39
- Single 39
- Default 40
- Multifunction knob 40
- Touch lock key 40
- User interface 41
- Pinch stretch 45
- Touch screen controls 45
- Rectangle drawing 46
- Parameter setting method 48
- To use the kensington security lock 49
- To use the built in help system 50
- To view the option information and the option installation 51
- Chapter 2 to set the vertical system 53
- To set the vertical system 53
- To enable or disable the analog channel 54
- To adjust the vertical scale 55
- To adjust the vertical offset 56
- Vertical expansion 56
- Bandwidth limit 57
- Channel coupling 57
- Probe ratio 58
- Input impedance 59
- Waveform invert 59
- Amplitude unit 60
- Channel delay 60
- Offset cal 61
- Channel label 62
- Chapter 3 to set the horizontal system 65
- To set the horizontal system 65
- To adjust the horizontal time base 66
- To adjust the horizontal position 67
- Delayed sweep 68
- Chapter 4 to set the sample system 71
- To set the sample system 71
- Timebase mode 72
- Xy mode 72
- Yt mode 72
- Roll mode 74
- Acquisition mode 75
- Average 75
- Normal 75
- High resolution 77
- Sample rate 77
- Sampling mode 77
- La sample rate 79
- Memory depth 79
- La memory depth 80
- Anti aliasing 81
- Horizontal expansion 81
- Note this function is unavailable in yt mode with the delayed sweep being enabled xy mode and roll mode 82
- Reset the user defined reference position to 0 82
- Chapter 5 to trigger the oscilloscope 83
- To trigger the oscilloscope 83
- Trigger source 84
- Trigger level threshold level 85
- Trigger mode 86
- Trigger coupling 87
- Trigger holdoff 88
- Noise rejection 89
- Trigger type 90
- Edge trigger 91
- Pulse trigger 92
- Slope trigger 94
- Video trigger 97
- Pattern trigger 99
- Duration trigger 101
- T time out t 103
- Time out 103
- Timeout trigger 103
- Runt trigger 105
- Window trigger 107
- Delay trigger 109
- Setup hold trigger 111
- Nth edge trigger 113
- Rs232 trigger option 114
- I2c trigger option 117
- Spi trigger option 119
- Can trigger option 121
- Flexray trigger option 124
- Lin trigger option 126
- I2s trigger option 128
- Mil std 1553 trigger option 131
- Zone trigger 133
- Trigger output connector 135
- Chapter 6 operations and measurements 137
- Operations and measurements 137
- Addition 138
- Math operation 138
- Subtraction 139
- Multiplication 140
- Division 141
- And operation 146
- Or operation 147
- Xor operation 148
- Not operation 150
- Lg base 10 exponential 154
- Low pass 157
- High pass 158
- Band pass 159
- Band stop 160
- Math operation label 162
- Auto measurement 163
- Quick measurement after auto 163
- Measurement parameter 165
- Time parameters 165
- Count values 166
- Delay and phase 167
- B delaya 168
- B phasea 168
- Period b delaya b phasea 168
- Voltage parameters 169
- Measurement settings 171
- Remove the measurement result 174
- Statistical function 174
- All measurement 175
- Cursor measurement 175
- Manual mode 177
- Track mode 181
- Xy mode 183
- Measure mode 185
- Chapter 7 digital voltmeter dvm and frequency counter 187
- Digital voltmeter dvm and frequency counter 187
- Digital voltmeter dvm 188
- To enable or disable dvm measurement 188
- To select the measurement source 188
- To select measurement mode 189
- To set the limits 189
- Frequency counter 190
- To enable or disable the frequency counter 190
- To select the measurement item 190
- To select the measurement source 190
- To clear count 191
- To enable or disable the statistical function 191
- To set resolution 191
- Chapter 8 power analysis option 193
- Power analysis option 193
- Power quality 194
- Ripple 196
- Chapter 9 histogram analysis 199
- Histogram analysis 199
- To enable or disable the histogram function 200
- To select the histogram type 200
- To enable or disable the statistical function 201
- To select the histogram source 201
- To set the histogram height 201
- To set the histogram range 201
- To reset 202
- Chapter 10 digital channel 203
- Digital channel 203
- To enable disable the digital channel 204
- To select the digital channel 204
- To set the threshold and calibrate probe 205
- Auto arrangement setting 206
- To set the label 206
- To set the waveform display size 206
- Group setting 207
- Waveform color of the digital channel 208
- Chapter 11 protocol decoding 209
- Protocol decoding 209
- Parallel decoding 210
- Rs232 decoding option 215
- Check bit 216
- Data bit 216
- Start bit 216
- Stop bit 216
- I2c decoding option 222
- Spi decoding option 226
- Lin decoding option 231
- Can decoding option 236
- Flexray decoding option 241
- I2s decoding option 245
- B decoding option 249
- Chapter 12 reference waveform 253
- Reference waveform 253
- To adjust the ref waveform display 254
- To enable ref function 254
- To select the ref source 254
- To select the reference channel 254
- To clear the display of the reference waveform 255
- To save to internal memory 255
- To view details of the reference waveform 255
- Color setting 256
- Label setting 256
- To reset the reference waveform 256
- To export to internal or external memory 257
- To import from internal or external memory 257
- Chapter 13 pass fail test 259
- Pass fail test 259
- To enable or disable the pass fail test function 260
- To select the source 260
- To start or stop the pass fail test operation 260
- To create a mask 261
- To load a mask 261
- To save the mask 261
- To set the output form of the test results 262
- Statistics reset 263
- To enable or disable the display of the statistics of the test results 263
- Chapter 14 waveform recording playing 265
- Waveform recording playing 265
- Common settings 266
- Record options 267
- Play options 268
- Chapter 15 search and navigation function 271
- Search and navigation function 271
- Search function 272
- Navigation function 274
- Key is disabled in the event navigation 275
- Number in the mark table decreases press 275
- To navigate to the next event the serial number in the mark table increases the 275
- Chapter 16 display control 277
- Display control 277
- To select the display type 278
- To set the persistence time 278
- To set the screen grid 279
- To set the waveform intensity 279
- Color grade 280
- Screen saver 280
- To set the grid brightness 280
- Waveform freeze 280
- Chapter 17 function arbitrary waveform generator option 283
- Function arbitrary waveform generator option 283
- To output basic waveforms 284
- To output sine 284
- To output square 285
- To output pulse 286
- To output ramp 286
- To output dc 287
- To output noise 287
- Exp rise 288
- Exp fall 289
- Lorentz 290
- Haversine 291
- To load the channel and waveform 291
- To output the arbitrary waveform 291
- To create the waveform 292
- To edit waveforms 294
- Modulation 295
- Chapter 18 store and load 303
- Store and load 303
- Storage system 304
- Storage type 304
- Load type 305
- Internal storage and load 306
- Disk management 308
- External storage and load 308
- To create a folder 309
- To select a file type 309
- English input method 310
- Simplified chinese or traditional chinese input method 312
- To delete a file or folder 313
- File or directory exists is displayed you are not allowed to execute the copy and paste operation 314
- To copy and paste a file or folder 314
- To rename a file or folder 314
- Factory settings 315
- To clear the internal memory safely 315
- Chapter 19 system utility function setting 327
- System utility function setting 327
- Lan configuration 328
- Network status 328
- Remote interface configuration 328
- Ip configuration type 329
- Apply the network parameter setting 331
- Mac address 331
- To set hdmi 331
- To set mdns 331
- Visa address 331
- To set the gpib address 332
- Usb connection 332
- Beeper 333
- Language 333
- Power on 333
- System information 333
- System related 333
- Aux output 334
- Auto config 335
- Self calibration 335
- Print setting 336
- Key locker 338
- Quick operation 339
- Self check 342
- System time 343
- Chapter 20 remote control 345
- Remote control 345
- Remote control via usb 346
- Remote control via lan 350
- Remote control via gpib 351
- Chapter 21 troubleshooting 353
- Troubleshooting 353
- Appendix 355
- Appendix a accessories and options 355
- Chapter 22 appendix 355
- Note for all the mainframes accessories and options please contact the local office of rigol 356
- Appendix b warranty 357
Похожие устройства
- Rigol DG811 Инструкция по эксплуатации(ENG)
- Rigol DG812 Инструкция по эксплуатации(ENG)
- Rigol DG821 Инструкция по эксплуатации(ENG)
- Rigol DG822 Инструкция по эксплуатации(ENG)
- Rigol DG831 Инструкция по эксплуатации(ENG)
- Rigol DG832 Инструкция по эксплуатации(ENG)
- Rigol DG952 Инструкция по эксплуатации(ENG)
- Rigol DG972 Инструкция по эксплуатации(ENG)
- Rigol DG992 Инструкция по эксплуатации(ENG)
- Rigol DL3021 Инструкция по эксплуатации(ENG)
- Rigol DL3021A Инструкция по эксплуатации(ENG)
- Rigol DL3031 Инструкция по эксплуатации(ENG)
- Rigol DL3031A Инструкция по эксплуатации(ENG)
- Rigol RSA3030 Инструкция по эксплуатации(ENG)
- Rigol RSA3030-TG Инструкция по эксплуатации(ENG)
- Rigol RSA3045 Инструкция по эксплуатации(ENG)
- Rigol RSA3045-TG Инструкция по эксплуатации(ENG)
- Rigol DS7014 Инструкция по эксплуатации(ENG)
- Rigol DS7024 Инструкция по эксплуатации(ENG)
- Rigol DS7034 Инструкция по эксплуатации(ENG)