Rigol DL3021A Инструкция по эксплуатации(ENG) онлайн [18/163] 394808
![Rigol DL3021A Инструкция по эксплуатации(ENG) онлайн [18/163] 394808](/views2/1472911/page18/bg12.png)
RIGOL Chapter 1 Quick Start
1-6 DL3000 User’s Guide
System Info
Displays the manufacturer, device model, software and
hardware versions, FPGA version, boot version, system boot
times, calibration date, and product serial number.
Reset
Restores the instrument settings to its factory default
settings, For default settings, refer to Table 2-3.
(3) Advanced function key
Provides advanced functions. Currently, the factory test function
and CC+CV function are supported.
(4) Storing and recalling operation key
Saves, reads, deletes, copies, and pastes the files. The
instrument provides an internal non-volatile memory ("Disk C")
and supports an external memory ("Disk D"). A maximum of 100
files can be stored in the instrument.
(5) Help key
Enters the built-in help system. You can view relevant help
information for any key or menu key on the front panel.
5. Knob
(1) Switch the parameters or parameter values.
(2) Increases (rotate clockwise) or decreases (rotate counterclockwise) the
value at the cursor.
Note: Rotating the knob in different interfaces can produce different operation
results. Here introduces its common usage. For other specific usages and
operation methods, refer to details in relevant chapters.
6. Input Control Keys
(1) Input on/off key
Enables or disables the sink function of the load.
(2) Transient trigger key
Turns on or off the transient trigger function.
(3) Short-circuit key
Enables or disables the short circuit function of the load.
Содержание
- Electronic load 1
- Feb 2018 1
- Rigol technologies inc 1
- User s guide dl3000 series programmable dc 1
- Contact us 3
- Copyright 3
- Guaranty and declaration 3
- Notices 3
- Product certification 3
- Publication number 3
- Software version 3
- Trademark information 3
- General safety summary 4
- Safety requirement 4
- Safety notices and symbols 6
- Care and cleaning 7
- Environmental considerations 7
- Dl3000 series overview 8
- Document overview 9
- Contents 11
- Chapter 1 quick start 13
- Quick start 13
- General inspection 14
- Appearance and dimensions 15
- Front panel 16
- Rear panel 22
- The current monitoring output terminal outputs the signal in analog quantity you can connect a device such as a digital oscilloscope through the terminal to display the current output from the output terminal so as to monitor the changes of input current of the load 24
- To connect to power supply 25
- Turn on checkout 25
- To power on the instrument 26
- Fuse replacement 27
- User interface 28
- To use the built in help system 29
- Parameter setting method 30
- Chapter 2 front panel operations 31
- Front panel operations 31
- Local operation mode 32
- Local remote operation mode 32
- Remote operation mode 32
- Constant current cc mode 33
- Static operation mode 33
- Constant voltage cv mode 37
- Constant resistance cr mode 41
- Constant power cp mode 45
- Cc continuous mode con 48
- Transient test function 48
- Cc pulsed mode pul 55
- Cc toggled mode tog 62
- List operation function list 68
- Application function 75
- Ocp test function 75
- Opp test function 83
- Battery test function 90
- Before replacing the battery do the battery test first 90
- Advanced function 95
- Factory test function 95
- Cc cv function 99
- Waveform display function 103
- Input control 107
- Turn on off the input 107
- Von latch function 107
- Short circuit operation 108
- Trigger operation 109
- Protection function 111
- Sense working mode 113
- Function of terminals on the rear panel 115
- Store and recall 116
- Cursor 117
- Copy and paste 120
- Delete 120
- System utility function 121
- Select the power on value 122
- Select the system language 122
- System 122
- Turn on off the beeper 122
- Enable disable the sense function 123
- Set digital input output 123
- Set the short circuit 124
- Turn on off current monitoring output terminal 124
- Turn on off log recording 124
- Turn on off voltage monitoring output terminal 124
- Enable disable the von latch function 125
- Set the screen brightness 125
- Communication interface setting 126
- Set the gpib address 126
- Set the parameters for the rs232 interface 127
- View usb id 127
- Set the parameters for the lan interface 129
- System info 134
- Option configuration 139
- Chapter 3 remote control 143
- Remote control 143
- Remote control via usb 144
- Remote control via lan 147
- Remote control via gpib 150
- Remote control via rs232 153
- Chapter 4 troubleshooting 157
- Troubleshooting 157
- Appendix 159
- Appendix a order information 159
- Chapter 5 appendix 159
- A 40 a 60 a test lead 160
- Accessories description 160
- Pin rs232 cable 160
- Sense cable 160
- Shield 160
- Usb gpib interface converter 160
- Rack mount kit for a single instrument 161
- Rack mount kit for two instruments 161
- Appendix b warranty 162
Похожие устройства
- Rigol DL3031 Инструкция по эксплуатации(ENG)
- Rigol DL3031A Инструкция по эксплуатации(ENG)
- Rigol RSA3030 Инструкция по эксплуатации(ENG)
- Rigol RSA3030-TG Инструкция по эксплуатации(ENG)
- Rigol RSA3045 Инструкция по эксплуатации(ENG)
- Rigol RSA3045-TG Инструкция по эксплуатации(ENG)
- Rigol DS7014 Инструкция по эксплуатации(ENG)
- Rigol DS7024 Инструкция по эксплуатации(ENG)
- Rigol DS7034 Инструкция по эксплуатации(ENG)
- Rigol DS7054 Инструкция по эксплуатации(ENG)
- Rigol MSO7014 Инструкция по эксплуатации(ENG)
- Rigol MSO7024 Инструкция по эксплуатации(ENG)
- Rigol MSO7034 Инструкция по эксплуатации(ENG)
- Rigol MSO7054 Инструкция по эксплуатации(ENG)
- Rigol RSA5032 Инструкция по эксплуатации(ENG)
- Rigol RSA5032-TG Инструкция по эксплуатации(ENG)
- Rigol RSA5065 Инструкция по эксплуатации(ENG)
- Rigol RSA5065-TG Инструкция по эксплуатации(ENG)
- Rigol RP1025D Инструкция по эксплуатации(ENG)
- Rigol RP1050D Инструкция по эксплуатации(ENG)