Beko WMD 55080 [18/48] Cleaning the pump filter

Содержание

Cleaning the pump filter Drain off the water completely before cleaning the foreign matter trap before transporting the machine e g when shifting house when there is a power failure emergency draining when there is a danger of frost At room temperatures below 0 C the remaining water in the appliance could freeze damaging it 1 Switch appliance off unplug the power cable close the water tap Allow hot suds to cool off sufficiently This poses a risk of scalding 2 Open the service door by pushing on the button Take out the drain pipe and hold it over a bowl Pull the seal off the drain hose and allow the water to drain out one bowl at a time There may be more than 20 litres of water left in the machine when the drum is bull e g after a power failure 3 Turn the foreign object trap 1 2 turn to loosen it anti clockwise and soak up the remaining water with a cloth Once no more water is coming out turn the foreign object trap until it is completely free and remove it 4 Clean foreign object trap and the pump opening Check if the pump impeller in the pump opening can be turned freely 5 Replace the cap on the drain hose and put it away 6 Replace the foreign object trap and turn it tight in clockwise direction 7 Close the service door Water inlet strainer Clean if water flows very slowly or not at all 1 Switch off the machine turn off the water tap 2 Take the inlet hose off 3 Pull out the strainer in Aquasafe or the two strainers in Aquasafe depending on the model with universal or needle nosed pliers clean with a small soft brush and fit back 16

Скачать