Iek ВА47-100 2Р 20А 10кА C [7/11] Complete set
![Iek ВА47-100 2Р 20А 10кА C [7/11] Complete set](/views2/1483963/page7/bg7.png)
Содержание
- Автоматические выключатели 1
- Для защиты от сверхтоков серии ва47 100 1
- Краткое руководство по эксплуатации 1
- Страница 1 1
- Условия эксплуатации 1
- Основные характеристики выключателей 2
- Страница 2 2
- Таблица 1 2
- Изменение характеристики расцепления выключателей 3
- Комплектность 3
- Страница 3 3
- И монтажа 4
- Правила и условия безопасного и эффективного использования 4
- Страница 4 4
- Условия транспортирования 4
- Условия хранения и утилизация 4
- Modular circuit breakers mcb for over current 5
- Operation conditions 5
- Protection va47 100 5
- Страница 5 5
- General parameters 6
- Time current operating characteristics at calibration control temperature 30 0 see figures 1 2 of appendix 1 claims concerning mcbswith damaged or open body are not accepted 6
- Страница 6 6
- Complete set 7
- Terms conditions of safe and efficient use and mounting 7
- Tripping characteristics change 7
- Страница 7 7
- Storage conditions and disposal 8
- Transportation conditions 8
- Страница 8 8
- Страница 9 9
- Страница 10 10
- Страница 11 11
Похожие устройства
- Iek ВА47-100 2Р 20А 10кА C Схема подключения
- Iek ВА47-100 2Р 20А 10кА D Габаритный Чертеж
- Iek ВА47-100 2Р 20А 10кА D Краткое руководство по эксплуатации
- Iek ВА47-100 2Р 20А 10кА D Схема подключения
- Iek ВА47-100 2Р 25А 10кА С Габаритный Чертеж
- Iek ВА47-100 2Р 25А 10кА С Краткое руководство по эксплуатации
- Iek ВА47-100 2Р 25А 10кА С Руководство По Эксплуатации
- Iek ВА47-100 2Р 25А 10кА С Схема подключения
- Iek ВА47-100 2Р 32А 10кА D Габаритный Чертеж
- Iek ВА47-100 2Р 32А 10кА D Краткое руководство по эксплуатации
- Iek ВА47-100 2Р 32А 10кА D Руководство По Эксплуатации
- Iek ВА47-100 2Р 32А 10кА D Схема подключения
- Comfee CMW207D02W Инструкция по эксплуатации
- Comfee CMW207M01W Инструкция по эксплуатации
- Comfee CMW207M02W Инструкция по эксплуатации
- Comfee CMW207M03W Инструкция по эксплуатации
- Comfee CF-BL801 Инструкция по эксплуатации
- Comfee CF-BL9001 Инструкция по эксплуатации
- Comfee CF-MC9501 Инструкция по эксплуатации
- Comfee CF-CM2501 Инструкция по эксплуатации
iEK Tripping characteristics change Tripping characteristics change of circuit breakers depends on two main factors the number of side by side placed close to each other MCBs and ambient temperature When non breaking current for side by side MCBs is calculated in depending on their number N and the ambient temperature t C correction coefficients are introduced Kn coefficient taking into account the number of side by side circuit breakers shall be determined according to the diagram introduced in Figures of Appendix 1 K coefficient taking into account the ambient temperature shall be determined according to the diagram introduced in Figure 4 of Appendix 1 Non tripping Inon irip current for the side by side MCBs depending on their number and the ambient temperature is determined according to following formula lnon ldp 1 13 In Kp Kt where 1 13ln conventional non tripping current of the breaker equal to 1 13 of its rated current indicated on the marking at the adjustment temperature of thermal release 30 C according to EN 60898 1 Complete Set VA47 100 1 pcs passport 1 pcs per a multiple package Terms Conditions of Safe and Efficient Use and Mounting Mounting and operation should be carried out in accordance with the acting federal requirements of electrical safety rules as well as other normative and technical documentation regulating exploitation adjustment and maintenance of electrical facilities Mounting connection and putting VA47 100 into operation should be performed onlyby qualified electrical personnel VA47 100are installed onto T rails35 mm wide according to the requirements of IEC 60715 Under normal operation afterthe expiration of its service life the device poses no hazard in further exploitation ATTENTION Before carrying out servicing or maintenance works make sure of the absence of line voltage IT IS RECOMMENDED to tighten contact terminals once every 6 months because their pressure tends to weaken because of cyclic variations of the ambient temperature and metal flow of the tightened conductors If the product fails it should be replaced ATTENTION More technical information can be found on thewebsite www iek ru 7