4.2. Operation
When the generating set is warm and the running speed has stabilised (after approximately 3 minutes):
n Check that the operating light is turned on (fig. A – no. 11, A).
o Activate the “MAX” or “ECO” mode (fig. A – no. 9).
p Connect the devices to the generating set sockets (fig. A – no. 8).
In case of overload or short-circuit, the operating light (fig. A – no. 11, A) switches–off and the overload indicator (fig. A – no. 11, B)
glows: Stop the generating set and eliminate the overload or the short-circuit.
4.2.1 MAX-ECO mode
MAX
When the button (Fig. A – No. 9) is set to "MAX", the generating set can quickly respond to a high inrush current (when running under no
load, it runs at 3800 rpm).
ECO
The "ECO" position is useful for small loads. To reduce noise emissions, the generating set runs at its min. speed (3000 rpm) between
0 and 200 W. When a power above 200 W is required, the speed of rotation gradually increases.
4.3. Switching off
n Shut down and disconnect the devices.
o Allow the engine to run idle for 1 or 2 min.
p Close the fuel tap (fig. A – no.3).
The generator set comes to a stop.
Always ensure suitable ventilation for the generating set.
Even after shut down, the engine continues to dissipate heat.
Warning
5. Safety features
5.1. Oil cut-out
If there is no oil in the engine sump or if the oil pressure is low, the oil safety mechanism automatically stops the engine to prevent any
damage.
If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
5.2. Circuit breaker
The set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the event of an
overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.
6. Maintenance schedule
6.1. Reminder of use
The maintenance operations to be carried out are described in the maintenance schedule. The interval for this is supplied as a guide
and for generating sets operating with fuel and oil which conform to the specifications given in this manual.
If the generating set is used under extreme conditions, the interval between the maintenance operations must be shortened.
Содержание
- 3 3 5 5 2 2 2 2 1 1 7 7 3 3 5 5 0 0 1 1 _ _ 2 2 _ _ 1 1 1
- M_3_ml_couverture pdf 1
- N n n e e e o o o 3 3 3 0 0 0 0 0 0 0 0 0 1
- Contents 5
- Instructions and safety regulations 5
- Pictograms and plates on the generating sets and what they mean 5
- Preface 1 recommendations 5
- Checking the oil level 8
- Earthing the generating set 8
- General description 8
- Preparation before use 3 positioning the generating set for operation 8
- Checking the air filter 9
- Checking the fuel level 9
- Starting procedure 9
- Using the generator set 9
- Circuit breaker 10
- Maintenance schedule 6 reminder of use 10
- Operation 10
- Safety features 5 oil cut out 10
- Switching off 10
- Checking bolts nuts and screws 11
- Cleaning the fuel strainer 11
- Maintenance procedures 11
- Maintenance table 11
- Renewing the engine oil 11
- Cleaning the air filter 12
- Cleaning the generating set 12
- Replacing the fuel filter 12
- Specifications 13
- Storing the generating set 13
- Troubleshooting 13
- Cable sizes 14
- Ec declaration of conformity 14
- Правила техники безопасности 15
- Предварительная информация 1 рекомендации 15
- Символы и таблички на генераторных установках и их значение 15
- Содержание 15
- Заземление генераторной установки 18
- Общее описание 18
- Подготовка перед применением 3 место эксплуатации 18
- Проверка воздушного фильтра 19
- Проверка уровня масла 19
- Проверка уровня топлива 19
- Процедура запуска 19
- Эксплуатация генераторной установки 19
- Выключатель 20
- Выключение установки 20
- Защитные устройства 5 устройство безопасности системы смазки 20
- Работа установки 20
- Замена моторного масла 21
- Операции технического обслуживания 21
- Порядок технического обслуживания 6 напоминание 21
- Проверка винтовых соединений 21
- Таблица обслуживания 21
- Замена топливного фильтра 22
- Очистка воздушного фильтра 22
- Очистка топливного фильтра 22
- Проверка свечи зажигания 22
- Очистка генераторной установки 23
- Устранение незначительных неисправностей 23
- Хранение генераторной установки 23
- Декларация соответствия нормам ес 24
- Сечение проводов 24
- Характеристики 24
Похожие устройства
- Sdmo SH 6000 Руководство пользователя
- Sdmo SH 6000 E Руководство пользователя
- Sdmo SH 7500 T Руководство пользователя
- Sdmo SH 7500 TE Руководство пользователя
- Honda EU 30 i RG Руководство пользователя
- FG Wilson P 220 Руководство пользователя
- FG Wilson P 275 Руководство пользователя
- Europower EP 10000 TE Руководство пользователя
- Europower EP 11000 E Руководство пользователя
- Europower EP 12000 TE Руководство пользователя
- Daewoo DDAE 8000SE Руководство пользователя
- Daewoo DDAE 8000SE-3 Руководство пользователя
- Daewoo DDAE 11000XE Руководство пользователя
- Daewoo DDAE 11000DХE-3 Руководство пользователя
- Daewoo DDAE 11000SE Руководство пользователя
- Daewoo DDAE 11000DSE-3 Руководство пользователя
- ТКМ V3 40 А Руководство пользователя
- ТКМ V3 63 А Руководство пользователя
- ТКМ V3 32 А Руководство пользователя
- ТКМ RC-1 Руководство пользователя