Allen&Heath WZ3 20S [31/32] Пользовательские настройки переключение реле выхода ав

Allen&Heath WZ3 20S [31/32] Пользовательские настройки переключение реле выхода ав
31 WZ
3
20S  
  -    AB
 AB    
TRS  ,  
.   
     
  .   -
 ,   
    
.     
    . 
 ,   
    REMOTE 
.
    
  .   
M3x6 Torx    .
   M3x6 Torx  
 .    
.
 GND, A B    
. A B a 
.  ,   A
B  .   ,
     A 
 GND.       A
B.
    
 A B,   
  ,     ,
    .
   , 
 ,     
TRS jack-.
 6  M3
EXTERNAL DC IN
ONLY USE RECOMMENDED ALLEN&HEATH POWER SUPPLY.
REFER TO USER GUIDE FOR DETAILS.
WARNING: THIS APPARATUS MUST BE EARTHED
DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
RISK OF ELECTRIC SHOCK
CAUTION
DO NOT OPEN
ATTENTION: REMPLA CER LE FUSIBLE AVEC UN DES MEMES CARACTERIS TIQUES.
CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
REFER SERVIC ING TO QUA LIFIED SERVICE PERS ONNEL.
100 - 240V~ 47-63Hz 45W MAX
AC MAINS IN ~
FUSE
T630mA L 250V 20mm
ON
I0
OFF
Made in the UK by ALLEN & HEATH Limited Serial No.
BACKUP SUPPLY
9
A
910
G4
B
AUX 6
R
R L
SENDS
G2G3 G1
AUX
REVERSE
GRP/AUX
INSERT
INSERT
3
A3
OUT
4
OUT
A4
LISTEN WEDGE
MATRIX OUT
RETURN
R
L
MONITOR OUT
OUT
L
M
R
2-TRACK
L
SEND
A5
INSERT
R
OUT
A6
OUT
INSERT
L
13-14
A1
INSERT
2
OUT
A2
OUT
INSERT
1
ST4
ST3
L/M
R
R
L/M
MIC
LINE IN
OUT
DIRECT
10
INSERT
L/M
ST2
R
R
ST1
11-12
L/M
OUT
DIRECT
MIC
LINE IN
9
10 INSERT
12345678
MIC
LINE IN
OUT
DIRECT
INSERT
MIC
LINE IN
OUT
DIRECT
8
INSERT 8
OUT
DIRECT
MIC
LINE IN
76
7INSERT
OUT
DIRECT
MIC
LINE IN
5
6 INSERT 5
LINE IN
OUT
DIRECT
MIC
4
INSERT 4
LINE IN
DIRECT
INSERT
OUT
DIRECT
LINE IN
MIC
3
OUT
MIC
2
INSERT 3
DIRECT
OUT
LINE IN
MIC
1
2 INS ERT 1
- IN
+IN
3
INPUT
2 1
RING -INRING
TIP +INTIP
LINE
MIC
TIP
RING
SEND
RETURN
XLR OUT
- OUT
3
21
INSERT
+OUT
SYS-LINK OUT ( option ) SYS-LINK IN ( option )
MixWizard WZ
3
14:4:2
AUX 5AUX 4AUX 3AUX 2AUX 1
ALLEN&HEATH
 2  M3 TORX   
A-B
LEV
TIP= +
A OUT
A-B
-2dBu IMPEDANCE BALANCED
TIP= +
A OUT
A
B
TRACK LINK GND
RELAY MUTE OPTION
SWITCH TO GND TO MUTE
A+B RLY OPTION
B
A
GND
 

Содержание

Пользовательские настройки переключение реле выхода АВ УДАЛИТЕ 6 ШУРУПОВ М3 С выхода АВ сигналы направляются на разъемы TRS посредством реле которое обычно включено Дистанционный переключатель может быть припаян к плате разъемов для отключения реле и изоляции выхода Одно применение в вещательной студии где монитор следует приглушить при активности его локального микрофона В этом случае реле должно быть распаяно на фейдере микрофонного канала Для внешнего переключения реле должно быть распаяно к пинам на порту REMOTE задней панели Данная настройка требует внутреннего доступа к блоку зандних разъемов Открутите два шурупа МЗхб Тогх с каждой стороны панели разъемов Открутите шесть шурупов МЗхб Тогх на задней панели разъемов Осторожно вытащите панель из консоли Найдите ЭМО А и В на припойной стороне схемы разъемов А и В аобъединены с маленьким трэком Является нормальным когда выходы А и В вклочаются одновременно Для включения реле чтобы они изолировали выход свяжите А с одним из ЭМО Это оказывает влияние на оба выхода А и В Если необходимо независимое реле включения выхода А и В обрежьте соединительный трэк и свяжите два включения один из А с землей второй из В с землей Когда контакты включения закрыты релейные 31 WZ320S Руководство пользователя

Скачать