SinePower Using the inverter
15
Check that the inverter is sufficiently ventilated and that the ventilation grilles are
unimpeded.
Wait 5 – 10 minutes and switch the inverter on again without any electric
consumers.
9.3 Switching to energy-saving mode
I
Activating energy saving mode
If necessary, switch the inverter off.
Press the on/off button (fig. 3 1) of the remote control until the status LED
(fig. 3 2) of the remote control has flashed six times.
Then the status LED (fig. 3 2) of the remote control flashes every 5 seconds.
Energy saving mode is activated.
Deactivating energy saving mode
Switch the inverter off.
Press the on/off button (fig. 3 1) of the remote control until the status LED
(fig. 3 2) of the remote control goes on constantly.
Before the status LED goes on constantly, it indicates that energy saving mode
will be switched off by an interval of flashing four times followed by flashing six
times.
Normal mode is activated.
NOTE
The inverter automatically switches to normal operation when a load
over 45 W is connected.
If an external switch is connected, you cannot change the energy
saving mode.