During extended periods of non-use
The macerator toilet and sanitation hoses should be protected if toilet will not be needed
for an extended period of time (more than two weeks, especially in hot weather).
1. Flush toilet and add 4 oz. (118 ml) of liquid biodegradable laundry detergent (should
NOT contain bleach or environmentally harmful substances).
Note: If using sea water for ushing, shut off power to sea water pump and add fresh
water directly into the bowl during the ush cycle.
2. Flush toilet at least ve times.
3. Turn off water supply to toilet.
4. Flush the toilet without water very briey to evacuate all water. (This procedure will
minimize any remaining water in the macerator pump.)
Caution
During water evacuation process, do not operate sea water pump very
long without water. Pump impeller may become damaged.
5. Turn off power to the toilet.
6. After extended periods of non-use, toilet and pump may dry. For easier re-start of
toilet system, add one quart of water to bowl and let it stand for a few minutes before
use.
The statutory warranty period applies. If the product is defective, please contact your
retailer or the manufacturer’s branch in your country (see the back of the instruction
manual for the addresses).