5. Transport and Storage
Never use the cable or the discharge hose/pipe to lift,
lower, transport or attach the pump. Always use the han-
dle or a rope or a chain attached to the handle.
The pump may be transported and stored in vertical
or horizontal position. Make sure that it cannot roll or fall
over. For longer periods of storage, the pump should be
protected against moisture, frost or heat.
6. Electrical Connection
Before operation, an expert check must secure that
the required electrical protection measures exist. The
connection to ground, earthing, isolating transformer, fault
current breaker or fault voltags circuit must correspond to
the guidelines set forth by the responsible power plant.
The voltage required in the technical data sheet
must correspond to the existing line voltage.
Submersible pumps used outside of buildings must
have a cable with a minimum length of 10m.
Make sure that the electrical pin-and-socket connec-
tions are installed flood- and moisture-safe. Before start-
ing operation check the cable and the plug against dam-
ages.
The end of the pump power supply cable must not be
submerged in order to prevent water from penetrating
through the cable into the motor.
The normal separate motor starter/control box of
standard as well as of explosion proof pumps must
not be installed in explosive enviroments.
6.1. Connection of 1 Ph-Motors
Barracuda GRP pumps with 1Ph-motors must be con-
nected to a separate control box with motor starter and
both starting capacitor and operating capacitor, available
from the HOMA accessory program. If any other control
unit is used, make sure that the thermal relay in the motor
starter is set according to the nominal current consump-
tion of the pump motor (see data on pump label).
For capacitor sizes, see table below:
Pump type Starting capacitor Operating capacitor
µF
V
AC
µF
V
AC
GRP 16 W(Ex) 60 330 30 450
GRP 26 W(Ex) 100 320 50 450
6.2. Connection of 3 Ph-Motors
Barracuda GRP pumps with 3Ph-motors must be con-
nected to a separate control box with motor starter, avail-
able from the HOMA accessory program. If any other con-
trol unit is used, make sure that the thermal relay in the
motor starter is set according to the nominal current con-
sumption of the pump motor (see data on pump label).
Motor-Start
The motors of pump types GRP 16 up to GRP 36 are de-
signed for direct-on-line start. All motors with 400 V volt-
age indication on the pump label have their motor wind-
ings internally star-connected for operation at 400 V / 3Ph
power supply. The motor cable wires indicated U, V. W
must be connected to the power supply wires indicated
L
1
, L
2
, L
3
through the motor starter according to fig. 1.
The motors of the pump types GRP 44 up to GRP 111
are prepared for star-delta start. This means that each
end of each of the stator windings is connected to one
pump cable wire. The wires are marked U
1
/U
2
, V
1
/V
2
,
W
1
/W
2
. For star-delta start, the pump must be connected
to an appropriate starter box (see fig. 2 and 3).
If a motor, which is prepared for star-delta start as de-
scribed above, is supposed to operate with direct-on-line
(DOL) start at 400 V / 3 Ph power supply, the pump cable
wires must be delta-connected in the starter box (see fig.
4).
6.3. Temperature Sensors
All Barracuda GRP pumps have a set of temperature
sensors built in the stator windings. The contact of these
sensors opens in case of overtemperature and switches
off the motor power supply.
Standard models of 1Ph-motors up to 1,6 kW have the
sensors internally connected, so that no external connec-
tion to the control box is necessary. When the motor
cools, it is switched on again automatically.
Standard models above 1,6 kW and all 3Ph-motors have
the sensors connected to the motor power supply cable,
the wire Endes marked T
1
and T
3
. They must be con-
nected to the safety circuit of the control box in order to
Profite an automatic re-start of the motor, when the mo-
tors cools. The Switch-off temperature of the sensors for
standard models is approx. 130°C.
Explosion proof models (1 Ph and 3 Ph) have a set of
temperature sensors with a higher switch-off temperature
of approx. 140°C, connected to the motor cable, the wires
are marked T1 and T2.
The pump types GRP 16 up to GRP 50 have a set of
lock-out-device sensors instead of the standard sensors.
They must be connected to the safety circuit of the control
box in order to provide a manual re-start, when the motor
cools.The pump re-start of these models must be done by
switch-off the mains power supply and switch-on again
after approx. 5 minutes (see fig.1).
The pump types GRP 56 up to GRP 111 have the Ex-
sensor built-in, which are no lock-out-device.They must
be connected to a special relay in the starter box in order
to provide manual pump re-start (see. fig. 2).
6.4. Oil Chamber Seal Condition Sensors
The pump types GRP 56 up to GRP 111 have a moisture
sensor device of the pump oil-chamber. Available upon
request for the pump types GRP 22 up to GRP 50. It
measures the electrical resistance of the oil in the cham-
ber. In case of water entering the chamber through the
shaft seals, the resistance will change. The standard
models have one sensor, that measures the resistance
against ground (motor housing). The sensor is connected
to the pump cable, the wire end is marked S1 (see fig. 1
and 2).
The explosion-proof models have two sensors between
which the resistance is measured. The sensors are con-
nected to the pump cable, the wire ends are marked S1
and S2 (see fig. 1 and 2). The sensor(s) must be con-
nected to a tripping unit, which is connected to the safety
circuit of the pump controller. For explosion-proof models
there has to be an intrinsically-safe relay. The tripping
unit should have an adjustable sensitivity of 0 to 100 kΩ,
standard setting is approx. 50 kΩ.
Содержание
- Barracuda grp 1
- Baureihe series serie 1
- Montage und bedienungsanleitung installation and operation instruction manual montage en bedrijfsinstrukties 1
- Inhaltsverzeichnis 3
- Konformitätserklärung 3
- Einsatz und technische beschreibung 4
- Sicherheitshinweise 4
- Elektroanschluss 5
- Garantie 5
- Transport und lagerung 5
- Montage und installation 6
- Inbetriebnahme 7
- Wartung und reparatur 7
- Grp 111 1 9 l 8
- Grp 16 0 7 l 8
- Grp 22 1 0 l 8
- Grp 26 1 0 l 8
- Grp 36 1 0 l 8
- Grp 44 1 4 l 8
- Grp 50 1 4 l 8
- Grp 56 1 9 l 8
- Grp 76 1 9 l 8
- Pumpentyp ölmenge in ölkammer 8
- Störungen ursache abhilfe 8
- Vor jeder wartung pumpe vom stromnetz trennen netzstecker ziehen 8
- Für die tauchmotorpumpe nr leisten wir entsprechend unseren garantiebedingungen 9
- Garantiebedingungen 9
- Garantieschein 9
- Homa vertragskundendienste im bundesgebiet 9
- Monate garantie 9
- Contents 10
- Declaration of conformity 10
- Applications and technical description 11
- Safety warnings 11
- Warranty 11
- Electrical connection 12
- Transport and storage 12
- Installation 13
- Start up 13
- At pump types with oil chamber an overpressure can escape with loosening of the oil chamber control screw screw only when pressure balance took place pumps running under normal operation conditions should be inspected at least once a year if the pumped liquid is very muddy or sandy or if the pump is operating continu ously the pump should be inspected every 1 00 operat ing hours for long and trouble free operation of the pump following points should be checked regularly nominal current a check with amp meter 14
- Ball bearings check the shaft for noisy or heavy opera tion turn the shaft by hand replace defective ball bear ings a general overhaul of the pump is usally required in case of defective ball bearings or poor motor function this work must be carried out by an authorized service workshop 14
- Before carrying out maintenance and service the pump must be thoroughly flushed with clean water rinse the pump parts in clean water after dismanteling 14
- Before maintenance or repair disconnect the pump from the power supply to avoid accidental starting of the pump 14
- Before maintenance or repair make sure that all rotat ing parts stand still 14
- Cable entry make sure that the cable entry is watertight and that the cables are not bent sharply and or pinched additionally at pump types with oil chamber oil level and oil condition in oil chamber put the pump in horizontal position so that the screw of the oil chamber is above at larger pumps one of both screws remove the screw and infer a small quantity of oil the oil becomes greyish white like milk if it contains water this may be the result of defective shaft seal in this case leave the condition of the shaft seals by a homa service to examine the oil should be replaced after 3000 operating hours oil type shell tellus c22 degradable homa atox avail able on request used oil is to be disposed accordingly servicing contract for a regular expert execution of all necessary mainte nance and inspection we recommend the conclusion of a servicing contract by our homa service please contact our homa customer service 14
- Fault finding chart 14
- Grp 111 1 9 l 14
- Grp 16 0 7 l 14
- Grp 22 1 0 l 14
- Grp 26 1 0 l 14
- Grp 36 1 0 l 14
- Grp 44 1 4 l 14
- Grp 50 1 4 l 14
- Grp 56 1 9 l 14
- Grp 76 1 9 l 14
- In accordance with the product liability law we point out that we shall not be liable for damages caused by our product due to unauthorized repair by persons other than the manufacturer or an authorized workshop or due to the use of spare parts other than original homa parts the same product liability limitations are valid for accessories 14
- In case of a defect of the pump a repair shall be car ried out only by the manufacturer or through an author ized workshop modifications of the pump must be con firmed by the manufacturer only homa spare parts shall be used 14
- Maintenance and repair 14
- Oil chamber 14
- Pump parts and impeller check for possible wear replace defective parts 14
- The following table states how much oil the pumps must have in the oil chamber pump type quantity of oil in 14
- Months of warranty 15
- Pump type no correspond to our warranty conditions we achieve 15
- Warranty conditions 15
- Warranty receipt 15
- Conformiteitsverklaring 16
- Inhoudsopgave 16
- Inzetbaarheid en technische beschrijving 17
- Veiligheidsvoorschriften 17
- Elektrische aansluiting 18
- Garantie 18
- Transport en opslag 18
- Montage en installatie 19
- In bedrijf stellen 20
- Onderhoud en service 20
- Garantiebepalingen 21
- Garantiebewijs 21
- Maanden garantie 21
- Opsporen van storingen 21
- Voor de vuilwater dompelpomp nr geven wij conform onze bovenstaande garantiebepalingen 21
- Voor elke reparatie aan pomp stroomtoevoer uitschakelen 21
- Anschlussdiagramme wiring diagrams aansluitschema 22
- Baumaße dimensions afmetingen in mm 24
- Grp 16 ex grp 22 ex grp 26 ex grp 36 ex grp 44 ex grp 50 ex 24
- Grp 56 ex grp 76 ex grp 111 ex maße dimensions afmetingen 24
- Maße dimensions afmetingen maße dimensions afmetingen 24
- Doppelanlagen double station dubbel pompstation 25
- Doppelstation double station dubbel pompstation maße dimensions afmetingen einzelanlage single station enkel pompstation 25
- Schachtinstallation mit kupplungssystem 14 submerged installation with auto coupling 14 installatie met automatische koppeling einzelstation single station enkel pompstation 25
- Achtung die untenstehende liste enthält teile die nicht in jedem pumpentyp vorhanden sind deshalb bei ersatzteilbestellung bitte immer angeben pumpentyp baujahr siehe typenschild auf der pumpe zeichnungsposition xx genaue positionsnummer bitte aus der ersatzteilzeichnung entnehmen und bei bestell ung angeben siehe unten artikelbezeichnung siehe unten gewünschte stückzahl 28
- Attention the following list contains parts that do not correspond to every pump type for spare part orders please always give pump type the year of construction see the pump label position number xx take the exact position number from the drawing of the specific pump model see hereafter part description see hereafter required quantity 28
- Ersatzteilliste 28
- Ersatzteilliste und zeichnungen 28
- Spare part list 28
- Spare part list and drawings 28
- De onderstaande lijst bevat delen die niet in elk pomtype aanwezig zijn daarom bij onderdelenbestelling altijd vermelden 29
- Onderdelenlijst en onderdelentekening 29
- Onderdelenlijst let op 29
- Pomptype bouwjaar zie typeplaatje tekeningpositie xx exacte positienummer uit de onderdelenlijst vermelden bij bestelling artikelomschrijving gewenste aantal 29
- Notizen notes 34
Похожие устройства
- Homa Barracuda GRP 16 B DA Технические данные
- Homa Barracuda GRP 20 D Инструкция по эксплуатации
- Homa Barracuda GRP 20 D Технические данные
- Homa Barracuda GRP 20 DA Инструкция по эксплуатации
- Homa Barracuda GRP 20 DA Технические данные
- Homa Barracuda GRP 26 D Инструкция по эксплуатации
- Homa Barracuda GRP 26 D Технические данные
- Homa Barracuda GRP 26 DA Инструкция по эксплуатации
- Homa Barracuda GRP 26 DA Технические данные
- Homa Barracuda GRP 36 D Инструкция по эксплуатации
- Homa Barracuda GRP 36 D Технические данные
- Homa Barracuda GRP 36 DA Инструкция по эксплуатации
- Homa Barracuda GRP 36 DA Технические данные
- Homa Barracuda GRP 36 HD Инструкция по эксплуатации
- Homa Barracuda GRP 36 HD Технические данные
- Homa Barracuda GRP 36 HDA Инструкция по эксплуатации
- Homa Barracuda GRP 36 HDA Технические данные
- Homa Barracuda GRP 44 D Инструкция по эксплуатации
- Homa Barracuda GRP 44 D Технические данные
- Homa Barracuda GRP 50 D Инструкция по эксплуатации