Homa Barracuda GRP 36 DA [11/36] Safety warnings
![Homa Barracuda GRP 16 WA [11/36] Safety warnings](/views2/1556299/page11/bgb.png)
11
2. Safety Warnings
2.1. General Instructions
Signs used to mark instructions in this manual
Safety instructions in these operating instructions,
which, if not observed, could cause a danger for persons
are marked with the general symbol in accordance with
DIN 4844-W 9.
Warnings against electrical voltage are marked with
the safety symbol in accordance with DIN 4844-W 8.
2.2. General Safety Precautions
General regulations and guidelines not mentoined in the
safety warnings retain their validity.
These operating instructions contain basic instruc-
tions, which have to be adhered to during installation, op-
eration and maintenance. These operating instructions
must be read from mechanic and the operator before in-
stallation and operation of the pump and have to be kept
available at the operating place of the machine/unit at all
times. Persons who are not familiar with the operating in-
structions shall not use this product.
Children and adolescents under age 16 shall not use
the pump and must keep away from the machine/unit
while it is operational.
The working area has to be closed off expediently
and must adhere to local workplace regulations.
Always use personal safety equipment such as safety
boots, rubber gloves, safety glasses and helmet.
Make sure that the emergency exit from the work-
place is not barricaded.
To prevent suffocation and poisoning caused by ven-
omous gases, make sure that enough oxygen exists at
the workplace.
If you have to work with welding tools or electric tools,
make sure that there is no explosion hazard.
Immediately after repair or maintenance work, all
safety and protection equipment must be reinstalled and
placed in function again.
The operator of the pump is responsible for third par-
ties within the work area.
Never put a hand or finger into suction inlet or dis-
charge of the pump while the impeller is rotating.
Persons are not permitted to stay in the pumping me-
dium during operation of the pump.
All other rules and regulations and local codes cover-
ing health and safety must be observed. In accordance
with product liability law, we point out that we shall not be
liable for damages caused by the pump due to non-
observance of the instructions and guidelines set forth in
the operating instructions. The same product liability are
valid for accessories.
3. Applications and Technical Description
3.1. Applications
If the pump is used for cleaning or maintenance of
swimming pools, make sure that no persons stay in the
swimming pool during operation of the pump and that the
pump is self-assured by a 30 mA earth leakage circuit
breaker.
Barracuda GRP pumps are designed for pumping waste
water, effluent or groundwater, containing sludge or soft
solids. The pumps are equipped with a cutter system at
the pump inlet which cuts all soft solids to small particles,
so that the liquid may be pumped through small diameter
discharge pipes of 50 mm ø.
The pumps are used for installations of conventional
sewer systems in areas of low population or under difficult
topographic conditions.
The pumps must not be used for pumping of liquids con-
taining great quantities of abrasive solids, like sand or
stones. Before the pumping of chemically aggressive liq-
uids, the resistance of the pump materials must be
checked.
The pumps may be used for both temporary or permanent
installation. The installation can be free-standing on a
base-stand or by means of an auto-coupling guide rail
system (available as accessory).
3.2. Technical Data
Discharge
GRP 16, GRP 22, GRP 26, GRP 36,
GRP 44, GRP 50
BSP 2" M
GRP 56, GRP 76, GRP 111 DN 50
Voltage
1Ph-motor (Model W) 230 V
3Ph-motor (Model D) 400 V
Speed 2900 rpm
Insulation class F
Motor protection IP 68
Cable 10 m
Cable type H 07RN-F...
Noise level during operation, 1,60 m from the
ground
≤ 70d(B)A
3.3. Operating Conditions
Maximum liquid temperature
: 35°C, short term up to
60°C.
Density of pumped liquid:
max. 1100 kg/m
3
Ph-value of pumped liquid: 6 up to 11.
Level of pumped liquid: The lowest level must always
be above the top of the pump housing (volute).
Operation:
The motors are designed for continuous op-
eration (S1) with fully submerged motor, maximum 15
starts per hour.
Our standard warranty and maintenance regulations refer
to intermittent operation. For reduced warranty periods
and service intervals due to continuous operating condi-
tions please contact our service department.
3.4. Explosive Environments
For operation of the pumps in explosive environments
only models with explosion-proof motors (Ex model) must
be used.
For each individual installation the explosion classifi-
cation (Ex-class) of the pump must be approved by the
local authorities.
4. Warranty
Our warranty only covers pumps which are installed and
operated in accordance with these installation and opera-
tion instructions and accepted codes of good practice and
being used for the applications mentioned in these in-
structions.
Содержание
- Barracuda grp 1
- Baureihe series serie 1
- Montage und bedienungsanleitung installation and operation instruction manual montage en bedrijfsinstrukties 1
- Inhaltsverzeichnis 3
- Konformitätserklärung 3
- Einsatz und technische beschreibung 4
- Sicherheitshinweise 4
- Elektroanschluss 5
- Garantie 5
- Transport und lagerung 5
- Montage und installation 6
- Inbetriebnahme 7
- Wartung und reparatur 7
- Grp 111 1 9 l 8
- Grp 16 0 7 l 8
- Grp 22 1 0 l 8
- Grp 26 1 0 l 8
- Grp 36 1 0 l 8
- Grp 44 1 4 l 8
- Grp 50 1 4 l 8
- Grp 56 1 9 l 8
- Grp 76 1 9 l 8
- Pumpentyp ölmenge in ölkammer 8
- Störungen ursache abhilfe 8
- Vor jeder wartung pumpe vom stromnetz trennen netzstecker ziehen 8
- Für die tauchmotorpumpe nr leisten wir entsprechend unseren garantiebedingungen 9
- Garantiebedingungen 9
- Garantieschein 9
- Homa vertragskundendienste im bundesgebiet 9
- Monate garantie 9
- Contents 10
- Declaration of conformity 10
- Applications and technical description 11
- Safety warnings 11
- Warranty 11
- Electrical connection 12
- Transport and storage 12
- Installation 13
- Start up 13
- At pump types with oil chamber an overpressure can escape with loosening of the oil chamber control screw screw only when pressure balance took place pumps running under normal operation conditions should be inspected at least once a year if the pumped liquid is very muddy or sandy or if the pump is operating continu ously the pump should be inspected every 1 00 operat ing hours for long and trouble free operation of the pump following points should be checked regularly nominal current a check with amp meter 14
- Ball bearings check the shaft for noisy or heavy opera tion turn the shaft by hand replace defective ball bear ings a general overhaul of the pump is usally required in case of defective ball bearings or poor motor function this work must be carried out by an authorized service workshop 14
- Before carrying out maintenance and service the pump must be thoroughly flushed with clean water rinse the pump parts in clean water after dismanteling 14
- Before maintenance or repair disconnect the pump from the power supply to avoid accidental starting of the pump 14
- Before maintenance or repair make sure that all rotat ing parts stand still 14
- Cable entry make sure that the cable entry is watertight and that the cables are not bent sharply and or pinched additionally at pump types with oil chamber oil level and oil condition in oil chamber put the pump in horizontal position so that the screw of the oil chamber is above at larger pumps one of both screws remove the screw and infer a small quantity of oil the oil becomes greyish white like milk if it contains water this may be the result of defective shaft seal in this case leave the condition of the shaft seals by a homa service to examine the oil should be replaced after 3000 operating hours oil type shell tellus c22 degradable homa atox avail able on request used oil is to be disposed accordingly servicing contract for a regular expert execution of all necessary mainte nance and inspection we recommend the conclusion of a servicing contract by our homa service please contact our homa customer service 14
- Fault finding chart 14
- Grp 111 1 9 l 14
- Grp 16 0 7 l 14
- Grp 22 1 0 l 14
- Grp 26 1 0 l 14
- Grp 36 1 0 l 14
- Grp 44 1 4 l 14
- Grp 50 1 4 l 14
- Grp 56 1 9 l 14
- Grp 76 1 9 l 14
- In accordance with the product liability law we point out that we shall not be liable for damages caused by our product due to unauthorized repair by persons other than the manufacturer or an authorized workshop or due to the use of spare parts other than original homa parts the same product liability limitations are valid for accessories 14
- In case of a defect of the pump a repair shall be car ried out only by the manufacturer or through an author ized workshop modifications of the pump must be con firmed by the manufacturer only homa spare parts shall be used 14
- Maintenance and repair 14
- Oil chamber 14
- Pump parts and impeller check for possible wear replace defective parts 14
- The following table states how much oil the pumps must have in the oil chamber pump type quantity of oil in 14
- Months of warranty 15
- Pump type no correspond to our warranty conditions we achieve 15
- Warranty conditions 15
- Warranty receipt 15
- Conformiteitsverklaring 16
- Inhoudsopgave 16
- Inzetbaarheid en technische beschrijving 17
- Veiligheidsvoorschriften 17
- Elektrische aansluiting 18
- Garantie 18
- Transport en opslag 18
- Montage en installatie 19
- In bedrijf stellen 20
- Onderhoud en service 20
- Garantiebepalingen 21
- Garantiebewijs 21
- Maanden garantie 21
- Opsporen van storingen 21
- Voor de vuilwater dompelpomp nr geven wij conform onze bovenstaande garantiebepalingen 21
- Voor elke reparatie aan pomp stroomtoevoer uitschakelen 21
- Anschlussdiagramme wiring diagrams aansluitschema 22
- Baumaße dimensions afmetingen in mm 24
- Grp 16 ex grp 22 ex grp 26 ex grp 36 ex grp 44 ex grp 50 ex 24
- Grp 56 ex grp 76 ex grp 111 ex maße dimensions afmetingen 24
- Maße dimensions afmetingen maße dimensions afmetingen 24
- Doppelanlagen double station dubbel pompstation 25
- Doppelstation double station dubbel pompstation maße dimensions afmetingen einzelanlage single station enkel pompstation 25
- Schachtinstallation mit kupplungssystem 14 submerged installation with auto coupling 14 installatie met automatische koppeling einzelstation single station enkel pompstation 25
- Achtung die untenstehende liste enthält teile die nicht in jedem pumpentyp vorhanden sind deshalb bei ersatzteilbestellung bitte immer angeben pumpentyp baujahr siehe typenschild auf der pumpe zeichnungsposition xx genaue positionsnummer bitte aus der ersatzteilzeichnung entnehmen und bei bestell ung angeben siehe unten artikelbezeichnung siehe unten gewünschte stückzahl 28
- Attention the following list contains parts that do not correspond to every pump type for spare part orders please always give pump type the year of construction see the pump label position number xx take the exact position number from the drawing of the specific pump model see hereafter part description see hereafter required quantity 28
- Ersatzteilliste 28
- Ersatzteilliste und zeichnungen 28
- Spare part list 28
- Spare part list and drawings 28
- De onderstaande lijst bevat delen die niet in elk pomtype aanwezig zijn daarom bij onderdelenbestelling altijd vermelden 29
- Onderdelenlijst en onderdelentekening 29
- Onderdelenlijst let op 29
- Pomptype bouwjaar zie typeplaatje tekeningpositie xx exacte positienummer uit de onderdelenlijst vermelden bij bestelling artikelomschrijving gewenste aantal 29
- Notizen notes 34
Похожие устройства
- Homa Barracuda GRP 36 DA Технические данные
- Homa Barracuda GRP 36 HD Инструкция по эксплуатации
- Homa Barracuda GRP 36 HD Технические данные
- Homa Barracuda GRP 36 HDA Инструкция по эксплуатации
- Homa Barracuda GRP 36 HDA Технические данные
- Homa Barracuda GRP 44 D Инструкция по эксплуатации
- Homa Barracuda GRP 44 D Технические данные
- Homa Barracuda GRP 50 D Инструкция по эксплуатации
- Homa Barracuda GRP 50 D Технические данные
- Citizen BL9009-03B Инструкция по эксплуатации
- Citizen BR0051-59F Инструкция по эксплуатации
- Citizen BR0051-59G Инструкция по эксплуатации
- Citizen BR0040-55E Инструкция по эксплуатации
- Citizen BR0061-04E Инструкция по эксплуатации
- Citizen BR0101-01C Инструкция по эксплуатации
- Citizen BR0040-55A Инструкция по эксплуатации
- Citizen BR0080-18E Инструкция по эксплуатации
- Citizen BR0090-57E Инструкция по эксплуатации
- Citizen BR0040-55L Инструкция по эксплуатации
- Citizen BT0001-12E Инструкция по эксплуатации