Ada PROF-X6 А00160 Инструкция по эксплуатации онлайн [31/36] 5021
Содержание
- Measurement foundation 1
- Prof х6 хю 1
- Руководство по эксплуатации 1
- Оглавление 2
- Описание 3
- Технические характеристики 3
- Комплектация 4
- Pr0fx6 хю 6
- Конструктивные особенности прибора 6
- Pr0fx6 хю 7
- Использование теодолита 8
- Pr0fx6 хю 11
- Юстировка поверка теодолита 11
- Меры предосторожности 14
- Свидетельство о приемке и продаже 15
- Гарантийный талон 17
- Measurement foundation 19
- Prof x6 x10 19
- Eng contents 20
- Review 21
- Technical parameters 21
- Complete set 22
- Construction features 24
- How to use the instrument 26
- Adjusting the theodolite 29
- Precautions 32
- Certificate of acceptance and sale 33
- __________________________________________ _____________________ 33
- Before operating you should read service instruction 34
- Warranty card 34
- Www adainstruments com 36
Похожие устройства
- Fluke 773 Инструкция по эксплуатации
- LG MH-6352B Инструкция по эксплуатации
- Centurion NAD v.2 Инструкция по эксплуатации
- E-Mu TRACKER PRE USB Creative Professional Инструкция по эксплуатации
- Whirlpool AWE 9629 Инструкция по эксплуатации
- Ada PROF-X6 (с поверкой) Инструкция по эксплуатации
- LG MH-6346W Инструкция по эксплуатации
- Fluke 77 IV Инструкция по эксплуатации
- Echo AUDIOFIRE 12 Инструкция по эксплуатации
- Belkin F4U006er Инструкция по эксплуатации
- Centurion XANADU v.2 Инструкция по эксплуатации
- Siemens WS 10X47 AOE Инструкция по эксплуатации
- Ada ZCT 777 А00161 Инструкция по эксплуатации
- LG MH-6346QMS Инструкция по эксплуатации
- Fluke 787 Инструкция по эксплуатации
- Echo AUDIOFIRE 2 Инструкция по эксплуатации
- Belkin F5U404PerBLK Инструкция по эксплуатации
- Siemens WM 12S47 AOE Инструкция по эксплуатации
- Ada ProDigit 60 А00168 Инструкция по эксплуатации
- LG MH-6346QMB Инструкция по эксплуатации
PROF Repeat one more time the definition of collimation axis error c and calculate it s average _____________________ ______ value The value difference shouldn t exceed 6710 If this value is more than 6 you should A ______________________ do the adjustment The procedure of correcting of collimation axis error is described below T _______ 5 The adjustment of the place of zero MO of the vertical circle Fig 7 After leveling the instrument observation should be done on the target point at two positions of the circle of theodolite The locking knob 10 of the compensator should be ON The place of zero is calculated according to the following formula MO 0 5 fl fl for theodolites with precise system of reading of vertical angles from 0 MO 0 5 Jl n 360 for theodolites with precise system of reading of vertical angles from 90 Where fl and fl reading of vertical circle Repeat the definition of the place of zero MO and calculate average value The value shouldn t exceed 6 If this value is more than 6 you should do the adjustment in accordance with the adjustment c Focus the levelled instrument at the target and take the readings fl of the horizontal and vertical circles Calculate the correction with the help of following formulas correction 11 JI c for horizontal circle correction Jl fl MO for vertical circle Set the corrected report of H circle with the help of horizontal micrometer screw The same way set the corrected report of V circle With the help of the pin or screwdriver loosen adjustment screws to overlay the reticule image with the target Notice You should correct 2c first and only then MO Notice You can correct MO with the help of corrective screws under the protective cover plate 13 31 MEASUREMENT FOUNDATION