Vacon NXS0261-2A2H0SSF [10/12] Emc and installation environment

Vacon NXS0004-6A2L0SSS [10/12] Emc and installation environment
EMC and installation environment
The product family standard EN/IEC 61800-3 + A1 sets limits for both emissions and
immunity of radio frequency disturbances. The environment has been divided into the
1
st
and 2
nd
environments, i.e. in practice, the public and industrial networks, respectively.
Radio Frequency Interference (RFI) filters
are typically required to meet the EN/
IEC 61800-3 + A1 standard. These filters
are integrated in the VACON® NXS as
standard.
The 208–240 V and 380–500 V ranges of
the VACON® NXS (FR4-FR9) fulfills the
requirements of the 1st and 2nd
environments (H level: EN/IEC 61800-3
+ A1, category C2). No additional RFI
filters or cabinets are required. The
FR10-FR11 and the 500-690 V range of
the VACON® NXS fulfills the require-
ments of the 2nd environment (L-level:
EN/IEC 61800-3 + A1, category C3).
The units in the enclosure sizes of FR4,
FR5 and FR6 (the voltage range from
380 to 500 V) are also available with
extremely low-emission integrated EMC
filters (C level: EN/IEC 61800-3 + A1,
category C1). This is sometimes required
in very sensitive locations such as
hospitals.
VACON® NXS EMC Hospital Residential Area Commercial Light Industry Area Heavy Industry Marine
C
O
H R R R O O
L R R
T
R (IT Network) R (IT Network)
EMC selection table, restricted distribution
R = Required ; O = Optional
2
ND
ENVIRONMENT
1
ST
ENVIRONMENT
1
1
2
2
2 3 4 5
3
5
4
10 Danfoss Drives · DKDD.PB.913.A1.02

Содержание