Vacon NXS0034-6A2L0SSS [7/12] Vacon nxs standard i o
![Vacon NXS0048-2A2H1SSS [7/12] Vacon nxs standard i o](/views2/1563540/page7/bg7.png)
Other typical options
VACON® NXS standard I/O
Option Order typecode Availability Note
IP54 enclosure Factory option All Replace ‘2’ by ‘5’ in the type code, e.g. NXS02605A5H0 (SSS...)
IP5-FR_ FR4, FR5, FR6 IP54 kit, e.g. IP5-FR4
Through-hole mounting Factory option FR4-FR9 E.g. NXS02605ATH0STS..., IP54 back, IP21 front, kits available
Integrated brake choppers Standard FR4-6/230, 500 V E.g. NXS00455A2H1 (SSS...)
Factory option FR7- / 230 V, 500 V
FR6- / 690 V
E.g. NXS02605A2H1 (SSS...)
External brake resistors
(380 - 500 V range)
BRR-0022-LD-5 00035-00225
LD = Light duty: 5 sec nominal torque braking from
nominal speed decreasing linearily to zero, once per 120 sec.
HD = Heavy duty: 3 sec nominal torque braking at
nominal speed + 7 sec nominal torque braking from nominal
speed decreasing linearily to zero, once per 120 sec.
Replace LD by HD in the type code, e.g. BRR-0105-HD-5
Brake resistors are also available for 208-240 V and 500-690 V NXS drives
The brake resistor manual is available for more precise selection
BRR-0031-LD-5 00315
BRR-0045-LD-5 00385-00455
BRR-0061-LD-5 00615
BRR-0105-LD-5 00725-01055
BRR-0300-LD-5 01405-03005
Integrated brake resistors Factory option FR4-6/500 V Replace ‘1’ by ‘2’ in the typecode, e.g. NXS00455A2H2 (SSS...)
Light duty: 2 sec nominal torque braking from
nominal speed decreasing linearily to zero, once per 60 sec.
Graphical display panel Factory option All Replace ‘A’ by ‘G’, e.g. NXS00455G2H1 (SSS..), supports Chinese & Russian
PAN-G All Order typecode when ordered separately
Panel door installation sets DRA-02B (-04B, -15B) All Length of RS232C cable is specied in the typecode, e.g. DRA-02B includes
2-meter RS232C cable
Varnished circuit boards Factory option All Enclosure sizes FR4-FR8: replace the ‘S’ by ‘V’, e.g.
NXS00455A2H1SSV..., enclosure size FR9-FR11: replace ‘S’ by ‘G’
C-level RFI lters Factory option FR4-6/500 V Replace ‘H’ by ‘C’ in the typecode, e.g. NXS00455A5C1 (SSS..)
dU/dt & sinus lters Available for all drives
Terminal Defaults settings Programmable
1 +10V Reference voltage
2 AI1+ Frequency reference 0–10 V -10–+10 V, 0/4–20 mA
3 AI1- AI common (GND) Dierential
4 AI2+ Frequency reference 4–20 mA 0–20mA, 0/-10 V–10 V
5 AI2- AI common (dierential) GND
6 +24V Control supply (bidirectional)
7 GND I/O Ground
8 DIN1 Start forward Many possibilities
9 DIN2 Start reverse Many possibilities
10 DIN3 External fault input Many possibilities
11 CMA Common for DIN1 - DIN3 (GND) Floating
12 +24V Control supply (bidirectional)
13 GND I/O Ground
14 DIN4 Multi-step speed select 1 Many possibilities
15 DIN5 Multi-step speed select 2 Many possibilities
16 DIN6 Fault reset Many possibilities
17 CMB Common for DIN4 - DIN6 (GND) Floating
18 AO1+ Output frequency (0–20 mA) Many possibilities
19 AO1- AO common (GND) 4–20 mA, 0–10 V
20 DO1 READY, I ≤ 50 mA, U ≤ 48 VDC Many possibilities
Terminal Defaults settings Programmable
21 R01
RUN Many possibilities22 R01
23 R01
24 R02
FAULT Many possibilities25 R02
26 R02
Terminal Defaults settings Programmable
21 R01
RUN Many possibilities22 R01
23 R01
25 R02
FAULT Many possibilities
26 R02
28 TI1+
Thermistor
input fault
Warning, fault,
no response
29 TI1-
1...10 kΩ
mA
+24 V
GND
230 VAC
N
OPT-A1 OPT-A2
OPT-A3 (alternative)
+24 V
GND
230 VAC
N
PTC
7Danfoss Drives · DKDD.PB.913.A1.02
Содержание
- Features 2
- Vacon nxs is a compact ac drive in the power range of 0 7 560 kw and supply voltages of 208 690 v for heavy use in machines buildings and all branches of industry 2
- Vacon nxs the reliable choice 2
- Danfoss drives dkdd pb 13 a1 2 3
- Mains voltage 380 500 v 50 60 hz 3 standalone units 3
- Mains voltage 380 500 v 50 60 hz 3 wall mounted units 3
- Ratings and dimensions 3
- Danfoss drives dkdd pb 13 a1 2 4
- Hardware configurations standalone units 4
- Mains voltage 500 690 v 50 60 hz 3 standalone units 4
- Mains voltage 500 690 v 50 60 hz 3 wall mounted units 4
- Ratings and dimensions 4
- A2 00 00 00 5
- Danfoss drives dkdd pb 13 a1 2 5
- Mains voltage 208 240 v 50 60 hz 3 wall mounted units 5
- Type code key 5
- Vacon nxs 0003 5 a 2 h 1 s s s a1 a2 00 00 00 5
- An external 24 v supply option enables communication with the control unit even if the mains supply is switched off e g fieldbus communication and parameter settings 6
- Danfoss drives dkdd pb 13 a1 2 6
- Option boards 6
- Removable terminals snap in card installation automatic card identification and instructions on the drive help making quick connections if necessary the inputs outputs and fieldbus boards can be added in the field the vacon nxs is simply the most flexible frequency converter series on the market 6
- The vacon nxs units are delivered with opt a1 and opt a2 boards if the i o is not specified in many countries boards opt a1 and opt a3 are used as standard i o as the galvanically isolated thermistor input is often required 6
- There are no fixed inputs or outputs in the vacon nxs there are five slots a b c d and e for i o boards and a suitable board can be selected for each slot see the table below 6
- Vacon nxs control unit 6
- Danfoss drives dkdd pb 13 a1 2 7
- Opt a1 opt a2 7
- Opt a3 alternative 7
- Other typical options 7
- Vacon nxs standard i o 7
- A maximum of three values can be monitored simultaneously the multi monitoring feature 8
- Basic standard local remote multi step speed control 8
- First class usability 8
- Ncdrive for parameter setting copying storing printing monitoring and controlling 8
- Ncload for software updating and uploading special software to the drive 8
- The uncluttered text display panel with a well defined menu structure and functions such as automatic parameter copy and start up wizard makes commissioning and fine tuning as easy as possible 8
- The vacon pc tools require only an rs232c cable for communication with the drive no adapters etc required 8
- Vacon pc tools are available for download through our website at drives danfoss com 8
- Vacon pc tools include 8
- Vacon programming tool is available for makingtailor made software a license key and training required 8
- All in one application package standard water solutions application package option special applications several options 9
- Control with the integrated pid controller in most cases the default basic application is suitable and only the min max frequencies as well as motor nominal values must be set 9
- Package can be replaced by the water application package that contains several applications optimized for water handling there are also several other general purpose software applications available 9
- Pid control multi purpose control pump and fan control 9
- Software modularity 9
- Thanks to the modular software applications made by the vacon programming tool based on iec 61131 standard the all in one application 9
- The all in one application package has seven applications default settings and functionality of control inputs and outputs see tables below which can be selected with one parameter the application will also be requested by the start up wizard at the first power up with this single setting the controls can be programmed e g for two external control places or a pressure 9
- Emc and installation environment 10
- Emc selection table restricted distribution 10
- Environment 10
- Environments i e in practice the public and industrial networks respectively 10
- The product family standard en iec 61800 3 a1 sets limits for both emissions and immunity of radio frequency disturbances the environment has been divided into the 10
- Danfoss drives dkdd pb 13 a1 2 11
- Technical data 11
- Danfoss drives 12
- Danfoss drives is a world leader in variable speed control of electric motors we aim to prove to you that a better tomorrow is driven by drives it is as simple and as ambitious as that 12
Похожие устройства
- Vacon NXS0034-6A2L0SSS Краткое руководство
- Vacon NXS0034-6A2L0SSS Руководство по применению
- Vacon NXS0034-6A2L0SSS Руководство пользователя
- Vacon NXS0041-6A2L0SSS Брошюра
- Vacon NXS0041-6A2L0SSS Краткое руководство
- Vacon NXS0041-6A2L0SSS Руководство по применению
- Vacon NXS0041-6A2L0SSS Руководство пользователя
- NATIONAL NK-TP5011 Инструкция по эксплуатации
- Vacon NXS0052-6A2L0SSS Брошюра
- Vacon NXS0052-6A2L0SSS Краткое руководство
- Vacon NXS0052-6A2L0SSS Руководство по применению
- Vacon NXS0052-6A2L0SSS Руководство пользователя
- NATIONAL NK-TP5015 Инструкция по эксплуатации
- Vacon NXS0062-6A2L0SSS Брошюра
- Vacon NXS0062-6A2L0SSS Краткое руководство
- Vacon NXS0062-6A2L0SSS Руководство по применению
- Vacon NXS0062-6A2L0SSS Руководство пользователя
- NATIONAL NK-TP5030 Инструкция по эксплуатации
- Vacon NXS0080-6A2L0SSS Брошюра
- Vacon NXS0080-6A2L0SSS Краткое руководство