Advanced Control ADV 4.00 M420-M [10/72] Keyboard instruction
![Advanced Control ADV 132 M420-M [10/72] Keyboard instruction](/views2/1567038/page10/bga.png)
M420 General Flux Vector Control Inverter User Manual Trouble Shooting
9
3.1.3. Keyboard instruction
Tab.2. Keyboard function table
Key Name Function
PRG/ESC
Program/ Exit entry or exit ,return to primary menu
+
-
ENTER
ENTER entry into the menu interface ,confirm the setup parameters
increase (+) Increase in the data or function code
decrease (-) Decrease in the data or function code
》
shift key
Select the displayed parameters in turn on the stop display
interface and running display interface, the specific content
please refer to F7-29 and F7-30; when modifying
parameters, select the modification digit of parameters
RUN Run key used in running operation under keyboard control mode
STOP/RESET STOP/RESET
In the status of running, pressing it can stop the running
operation; in fault alarm status, it can be used as reset. The
characteristic of this key is limited by function code F7-02
QUICK/JOG direction/jog run
When F7-28 is set as 0, it’s used as jog run key. When
F7-28 is set as 1, it’s used as direction key, press this key
now, the direction will be reversed.
3.2. Organization Way of the Inverter Function Code
The meaning of the function code group of M420 as follows:
Function code
group
Function
description
Explanation
F0
~
FF
Basic function
parameter group
Compatible with M420 series of function code
H0
~
H3
2
nd
motor parameter
group
2
nd
motor parameter, acceleration and deceleration
time, control method, all can be set independently.
L0
~
L6
Enhancement
function parameter
group
System parameter set, custom-made user function code,
optimization control, AI/AO revising, master-slave
control, mechanical brake function and sleep function.
N0
~
NF
Professional
inverter function
selection group
Choose to use different professional inverter function
U0
~
U1
Monitoring
parameter group
U0 is the fault record parameter group; U1 is the user
monitoring parameter group, for the convenience to
check the relevant output status.
Содержание
- Fig inverters of 18 kw follow 2
- Inverter braking unit part of the matching function if there is demand when ordering 2
- Note this figure for adv 1 0 m420 m adv 18 m420 m 1 18 kw series 2
- Please specify 2
- Typical wiring 2
- Attention this figure is just for m420 series of inverter 22 75kw brake unit is the selective part plese declare it in order request if it s needed 3
- Fig inverters of 22 75kw 3
- Fig three phase inverter above 90kw 4
- Connect to the braking resistor for the ac drive of 7 kw and below 220 v and18 kw and below other voltage classes 5
- Connect to the single phase 220 vac power supply 5
- Connect to the three phase ac power supply 5
- Connecting terminals of braking resistor 5
- Connecting terminals of braking resistor connect to a braking resistor 5
- Grounding terminal grounding terminal must be grounded 5
- Main circuit terminals and wiring 5
- Main circuit terminals of three phase 5
- Output terminals connect to a three phase motor 5
- Positive and negative terminals of dc bus common dc bus input point 5
- Single phase power supply input terminals 5
- Three phase power supply input terminals 5
- Wiring precautions 5
- Control circuit terminals and wiring 6
- Operation and display 8
- Operation and display interface introduction 8
- Description of function led indicator 9
- Led display 9
- Keyboard instruction 10
- Organization way of the inverter function code 10
- Enter key 11
- Fig parameter setting operation flowchart 11
- Fig three level menu operation flow chart 11
- For example make function code f1 04 change from 0 0hz to 5 0hz 11
- Function code parameter of m420 inverter adopts three level menu it can view and monitor the parameter by operation panel the three level menu includes function parameter set level 1 menu function code level 2 menu function code setup value level 3 menu refer to fig 2 for the operation procedure in the state parameter interface it can check the different status parameter by the key 11
- In the status of the 11
- Instruction of function code viewing and modification methods 11
- Level menu but it will save the present parameter data and move to the next function code if press enter while it will give up the present parameter revising if press prg 11
- Menu the value can t be modified if the parameter doesn t have the flashing digit you can check the function code property description for the specific reasons 11
- Shift enter 11
- Tips when operating with the three level menu you can press prg or enter to return to 11
- Trouble shooting m420 general flux vector control inverter user manual 11
- Fault warnings and solutions 12
- Trouble shooting 12
- Common faults and treating methods 17
- Function code table 19
- F1 06 startup dc braking current pre excited current 0 25
- F1 07 startup dc braking time pre excited time 0 25
- F1 08 acceleration deceleration mode 0 linear 25
- S curve 0 25
- Fault type 67
Похожие устройства
- Advanced Control ADV 4.00 M420-M Общий каталог
- Advanced Control ADV 4.00 M420-M Руководство по эксплуатации
- Advanced Control ADV 4.00 M420-M Спецификация
- Advanced Control ADV 5.50 M420-M Краткое руководство
- Advanced Control ADV 5.50 M420-M Общий каталог
- Advanced Control ADV 5.50 M420-M Руководство по эксплуатации
- Advanced Control ADV 5.50 M420-M Спецификация
- Advanced Control ADV 7.50 M420-M Краткое руководство
- Advanced Control ADV 7.50 M420-M Общий каталог
- Advanced Control ADV 7.50 M420-M Руководство по эксплуатации
- Advanced Control ADV 7.50 M420-M Спецификация
- Advanced Control ADV 11.0 M420-M Краткое руководство
- Advanced Control ADV 11.0 M420-M Общий каталог
- Advanced Control ADV 11.0 M420-M Руководство по эксплуатации
- Advanced Control ADV 11.0 M420-M Спецификация
- Advanced Control ADV 15.0 M420-M Краткое руководство
- Advanced Control ADV 15.0 M420-M Общий каталог
- Advanced Control ADV 15.0 M420-M Руководство по эксплуатации
- Advanced Control ADV 15.0 M420-M Спецификация
- Advanced Control ADV 18.5 M420-M Краткое руководство
Скачать
Случайные обсуждения