Advanced Control ADV 315 M420-M [10/72] Keyboard instruction

Advanced Control ADV 132 M420-M [10/72] Keyboard instruction
M420 General Flux Vector Control Inverter User Manual Trouble Shooting
9
3.1.3. Keyboard instruction
Tab.2. Keyboard function table
Key Name Function
PRG/ESC
Program/ Exit entry or exit ,return to primary menu
+
-
ENTER
ENTER entry into the menu interface ,confirm the setup parameters
increase (+) Increase in the data or function code
decrease (-) Decrease in the data or function code
shift key
Select the displayed parameters in turn on the stop display
interface and running display interface, the specific content
please refer to F7-29 and F7-30; when modifying
parameters, select the modification digit of parameters
RUN Run key used in running operation under keyboard control mode
STOP/RESET STOP/RESET
In the status of running, pressing it can stop the running
operation; in fault alarm status, it can be used as reset. The
characteristic of this key is limited by function code F7-02
QUICK/JOG direction/jog run
When F7-28 is set as 0, its used as jog run key. When
F7-28 is set as 1, it’s used as direction key, press this key
now, the direction will be reversed.
3.2. Organization Way of the Inverter Function Code
The meaning of the function code group of M420 as follows:
Function code
group
Function
description
Explanation
F0
FF
Basic function
parameter group
Compatible with M420 series of function code
H0
H3
2
nd
motor parameter
group
2
nd
motor parameter, acceleration and deceleration
time, control method, all can be set independently.
L0
L6
Enhancement
function parameter
group
System parameter set, custom-made user function code,
optimization control, AI/AO revising, master-slave
control, mechanical brake function and sleep function.
N0
NF
Professional
inverter function
selection group
Choose to use different professional inverter function
U0
U1
Monitoring
parameter group
U0 is the fault record parameter group; U1 is the user
monitoring parameter group, for the convenience to
check the relevant output status.

Содержание