Advanced Control ADV 315 M420-M Краткое руководство онлайн [7/72] 459392

Advanced Control ADV 110 M420-M Краткое руководство онлайн [7/72] 459385
M420 General Flux Vector Control Inverter Basic Reference Guide
DI4-COM
Digital input 4
mode.
2) Impedance: 3.3 kΩ.
3) Input voltage range: 9 ~30V
4) HDI5 can be used as high-speed input
port.
HDI5-COM
Digital input 5
Analog output
AO1-GND
Analog output 1
Voltage or current output is decided by dial
switches CN2 and CN7.
Output voltage range: 0
10 V Output current
range: 020 mA
AO2-GND
Analog output 2
Digital output Y1-COME
Digital output 1
Optical coupling isolation, dual polarity open
collector output
Output voltage range: 0–24 V
Output current
range: 0–50 mA
Note that CME and COM are internally
isolated, but they are short circuit externally
when leaving factory (In this case Y1 is
driven by +24 V by default). If you want to
drive Y1 by external power supply,
the
external short circuit of CME and COM must
be switched off.
Communication
interface
485+,485-
Modbus
Communication
terminal
Modbus communication interface, it can
choose the communication matched
resistance through dial switch CN4.
If Profibus communication function is
needed, please choose CM580 series of
inverter, and use profibus DP card.
Relay output 1
T/A-T/B
NC terminal
Contact driving capacity:
AC 250V, 3 A, COSø = 0.4 DC 30V, 1A
T/A-T/C
NO terminal
Relay output 2
R/A-R/B
NC terminal
Contact driving capacity:
250 VAC, 3 A, COSø = 0.4 30 VDC, 1 A
R/A-R/C
NO terminal
Keyboard
extended line
interface
CN6
External
operation panel
interface
External operation panel and parameter
copy panel interface, take out the
bidirectional crystal head, it can expand the
standard network cable.

Содержание